Literature DB >> 21518588

Six-month clinical outcomes of Firebird 2TM sirolimus-eluting stent implantation in real-world patients with coronary artery diseases.

Jun-bo Ge1, Feng Zhang, Ju-ying Qian, Lei Ge, Xue-bo Liu, Jun Zhou.   

Abstract

BACKGROUND: The Firebird 2(TM) sirolimus-eluting stent (Firebird 2 stent) is a second-generation sirolimus-eluting stent which has a cobalt-chromium alloy stent platform, a brand new bracket structure, and two layers of styrene-butylenes-styrene polymer coatings with better biocompatibility. The Firebird 2(TM) cObalt-Chromium alloy sirolimus-elUting Stent registry (FOCUS registry) aimed to evaluate the safety and efficacy of the Firebird 2 stent in patients with coronary artery disease in daily practice.
METHODS: The FOCUS registry is a prospective, non-randomized, international multi-center, single-arm clinical registry. Between March 2009 and February 2010, 5084 patients receiving at least 1 Firebird 2 stent during daily clinical practice at 83 medical centers were enrolled.
RESULTS: Of the 5084 patients enrolled in the registry, 5077 and 5058 were respectively available for 30 days and 6 months follow-up. The 30-day rate of major adverse cardiac events (MACE) was 1.20%, including 13 cardiac deaths, 46 non-fatal myocardial infarction (MI), and 6 target vessel revascularization (TVR). At 6 months follow-up, the rate of MACE was 1.80%. There were 32 cardiac deaths, 48 non-fatal MI, and 15 TVR. According to the Academic Research Consortium definition, definite/probable stent thrombosis (ST) occurred in 0.43% (22/5058) of patients, including 8 cases of acute ST, 11 subacute ST, and 3 late ST.
CONCLUSION: The Firebird 2 stent showed the promising efficacy and safety at 30 days and 6 months in a real-world population of patients with coronary artery diseases.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21518588

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  4 in total

1.  A head to head comparison of XINSORB bioresorbable sirolimus-eluting scaffold versus metallic sirolimus-eluting stent: 180 days follow-up in a porcine model.

Authors:  Li Shen; Yizhe Wu; Lei Ge; Yaojun Zhang; Qibing Wang; Juying Qian; Zhifen Qiu; Junbo Ge
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-21       Impact factor: 2.357

2.  Long-term performance of the second-generation cobalt-chromium sirolimus-eluting stents in real-world clinical practice: 3-year clinical outcomes from the prospective multicenter FOCUS registry.

Authors:  Feng Zhang; Ji'e Yang; Juying Qian; Lei Ge; Jun Zhou; Junbo Ge
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

3.  Real-World Use Of Ultrathin-Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents In Patients With Coronary Artery Disease: 6-Month Clinical Outcomes.

Authors:  Prakash Ajmera; Ramesh Pothineni; Kamal Kumar Chawla; Sai Sudhakar Mantravadi; Pankaj Vinod Jariwala; Vinod Vijan; Vikrant Vijan
Journal:  Vasc Health Risk Manag       Date:  2019-10-18

4.  Satisfaction of astigmatic patients with toric nesofilcon A contact lenses.

Authors:  Jill Saxon; Marjorie J Rah; William T Reindel
Journal:  Clin Optom (Auckl)       Date:  2019-01-09
  4 in total