Literature DB >> 21515900

Measuring foam model shapes with a contact digitizer.

Joan E Sanders1, Michael R Severance.   

Abstract

BACKGROUND AND AIM: It is difficult to measure foam model shapes using contact digitizers because the stylus contact tends to get stuck in the soft foam. The aim of this paper is to describe a technique to overcome this challenge and to assess its effect on digitizer error. TECHNIQUE: A controlled laboratory study was conducted. Thirty trans-tibial socket models were measured using a custom mechanical digitizer. Models were coated with a thin layer of resin, and then the resin thickness measured and subtracted from the digitizer data. Error introduced to the measurement from presence of the resin was determined. RESULTS AND DISCUSSION: The technique did not introduce meaningful error to the digitizer data beyond that already present from other sources in the instrument. The total instrument error for the contact digitizer used was 0.1% for model volume and 0.05 mm for mean radii. The root-mean-square error for individual measurement points was 0.08 mm. While resin coating introduced error to the digitizer measurements, the effect on volume, mean radii and interquartile range accuracies was minimal. CLINICAL RELEVANCE: Accurate model measurements can assist clinical service providers in the identification of problems and the repair of carving equipment. This facilitates the delivery of high quality sockets to practitioners and patients.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21515900      PMCID: PMC4431541          DOI: 10.1177/0309364610394478

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  3 in total

1.  Central fabrication: carved positive assessment.

Authors:  Joan E Sanders; Michael R Severance; Timothy R Myers; Marcia A Ciol
Journal:  Prosthet Orthot Int       Date:  2011-03       Impact factor: 1.895

2.  A method for aligning trans-tibial residual limb shapes so as to identify regions of shape change.

Authors:  Santosh G Zachariah; Elizabeth Sorenson; Joan E Sanders
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2005-12       Impact factor: 3.802

3.  CAD/CAM transtibial prosthetic sockets from central fabrication facilities: how accurate are they?

Authors:  Joan E Sanders; Ellen L Rogers; Elizabeth A Sorenson; Gregory S Lee; Daniel C Abrahamson
Journal:  J Rehabil Res Dev       Date:  2007
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.