Literature DB >> 21514071

Prostate contouring variation: can it be fixed?

Eric L H Khoo1, Karlissa Schick, Ashley W Plank, Michael Poulsen, Winnie W G Wong, Mark Middleton, Jarad M Martin.   

Abstract

PURPOSE: To assess whether an education program on CT and MRI prostate anatomy would reduce inter- and intraobserver prostate contouring variation among experienced radiation oncologists. METHODS AND MATERIALS: Three patient CT and MRI datasets were selected. Five radiation oncologists contoured the prostate for each patient on CT first, then MRI, and again between 2 and 4 weeks later. Three education sessions were then conducted. The same contouring process was then repeated with the same datasets and oncologists. The observer variation was assessed according to changes in the ratio of the encompassing volume to intersecting volume (volume ratio [VR]), across sets of target volumes.
RESULTS: For interobserver variation, there was a 15% reduction in mean VR with CT, from 2.74 to 2.33, and a 40% reduction in mean VR with MRI, from 2.38 to 1.41 after education. A similar trend was found for intraobserver variation, with a mean VR reduction for CT and MRI of 9% (from 1.51 to 1.38) and 16% (from 1.37 to 1.15), respectively.
CONCLUSION: A well-structured education program has reduced both inter- and intraobserver prostate contouring variations. The impact was greater on MRI than on CT. With the ongoing incorporation of new technologies into routine practice, education programs for target contouring should be incorporated as part of the continuing medical education of radiation oncologists. Copyright Â
© 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21514071     DOI: 10.1016/j.ijrobp.2011.02.050

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  23 in total

Review 1.  Improving radiotherapy quality assurance in clinical trials: assessment of target volume delineation of the pre-accrual benchmark case.

Authors:  S Gwynne; E Spezi; D Sebag-Montefiore; S Mukherjee; E Miles; J Conibear; J Staffurth
Journal:  Br J Radiol       Date:  2013-02-07       Impact factor: 3.039

2.  Simulation as More Than a Treatment-Planning Tool: A Systematic Review of the Literature on Radiation Oncology Simulation-Based Medical Education.

Authors:  Michael K Rooney; Fan Zhu; Erin F Gillespie; Jillian R Gunther; Ryan P McKillip; Matthew Lineberry; Ara Tekian; Daniel W Golden
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-06-06       Impact factor: 7.038

Review 3.  Advances in Prostate Cancer Magnetic Resonance Imaging and Positron Emission Tomography-Computed Tomography for Staging and Radiotherapy Treatment Planning.

Authors:  Drew Moghanaki; Baris Turkbey; Neha Vapiwala; Behfar Ehdaie; Steven J Frank; Patrick W McLaughlin; Mukesh Harisinghani
Journal:  Semin Radiat Oncol       Date:  2016-08-31       Impact factor: 5.934

Review 4.  Moderately hypofractionated prostate external-beam radiotherapy: an emerging standard.

Authors:  Jarad M Martin; Stephane Supiot; Paul J Keall; Charles N Catton
Journal:  Br J Radiol       Date:  2018-01-31       Impact factor: 3.039

5.  A Prostate Fossa Contouring Instructional Module: Implementation and Evaluation.

Authors:  Jillian R Gunther; Stanley L Liauw; Seungtaek Choi; Abdallah S R Mohamed; Nikhil G Thaker; Clifton D Fuller; Christopher J Stepaniak; Prajnan Das; Daniel W Golden
Journal:  J Am Coll Radiol       Date:  2016-05-18       Impact factor: 5.532

6.  Proposal of a post-prostatectomy clinical target volume based on pre-operative MRI: volumetric and dosimetric comparison to the RTOG guidelines.

Authors:  Jennifer Croke; Jillian Maclean; Balazs Nyiri; Yan Li; Kyle Malone; Leonard Avruch; Cathleen Kayser; Shawn Malone
Journal:  Radiat Oncol       Date:  2014-12-23       Impact factor: 3.481

7.  Guidance of treatment decisions in risk-adapted primary radiotherapy for prostate cancer using multiparametric magnetic resonance imaging: a single center experience.

Authors:  Cedric Panje; Thierry Panje; Paul Martin Putora; Suk-Kyum Kim; Sarah Haile; Daniel M Aebersold; Ludwig Plasswilm
Journal:  Radiat Oncol       Date:  2015-02-22       Impact factor: 3.481

8.  PTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers.

Authors:  Christoph Oehler; Stephanie Lang; Peter Dimmerling; Christian Bolesch; Stephan Kloeck; Alessandra Tini; Christoph Glanzmann; Yousef Najafi; Gabriela Studer; Daniel R Zwahlen
Journal:  Radiat Oncol       Date:  2014-11-11       Impact factor: 3.481

9.  Variability in prostate and seminal vesicle delineations defined on magnetic resonance images, a multi-observer, -center and -sequence study.

Authors:  Tufve Nyholm; Joakim Jonsson; Karin Söderström; Per Bergström; Andreas Carlberg; Gunilla Frykholm; Claus F Behrens; Poul Flemming Geertsen; Redas Trepiakas; Scott Hanvey; Azmat Sadozye; Jawaher Ansari; Hazel McCallum; John Frew; Rhona McMenemin; Björn Zackrisson
Journal:  Radiat Oncol       Date:  2013-05-24       Impact factor: 3.481

10.  Variability in MRI vs. ultrasound measures of prostate volume and its impact on treatment recommendations for favorable-risk prostate cancer patients: a case series.

Authors:  Yonina R Murciano-Goroff; Luciant D Wolfsberger; Arti Parekh; Fiona M Fennessy; Kemal Tuncali; Peter F Orio; Thomas R Niedermayr; W Warren Suh; Phillip M Devlin; Clare Mary C Tempany; Emily H Neubauer Sugar; Desmond A O'Farrell; Graeme Steele; Michael O'Leary; Ivan Buzurovic; Antonio L Damato; Robert A Cormack; Andriy Y Fedorov; Paul L Nguyen
Journal:  Radiat Oncol       Date:  2014-09-09       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.