Classification of ring artifacts for their effective removal using type adaptive correction schemes.

Emran Mohammad Abu Anas1, Soo Yeol Lee, Kamrul Hasan.   

Abstract

High resolution tomographic images acquired with a digital X-ray detector are often degraded by the so called ring artifacts. In this paper, a detail analysis including the classification, detection and correction of these ring artifacts is presented. At first, a novel idea for classifying rings into two categories, namely type I and type II rings, is proposed based on their statistical characteristics. The defective detector elements and the dusty scintillator screens result in type I ring and the mis-calibrated detector elements lead to type II ring. Unlike conventional approaches, we emphasize here on the separate detection and correction schemes for each type of rings for their effective removal. For the detection of type I ring, the histogram of the responses of the detector elements is used and a modified fast image inpainting algorithm is adopted to correct the responses of the defective pixels. On the other hand, to detect the type II ring, first a simple filtering scheme is presented based on the fast Fourier transform (FFT) to smooth the sum curve derived form the type I ring corrected projection data. The difference between the sum curve and its smoothed version is then used to detect their positions. Then, to remove the constant bias suffered by the responses of the mis-calibrated detector elements with view angle, an estimated dc shift is subtracted from them. The performance of the proposed algorithm is evaluated using real micro-CT images and is compared with three recently reported algorithms. Simulation results demonstrate superior performance of the proposed technique as compared to the techniques reported in the literature.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 21513928     DOI: 10.1016/j.compbiomed.2011.03.018

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  6 in total

1.  Ring artefact in multidetector CT.

Authors:  Suheil Artul
Journal:  BMJ Case Rep       Date:  2013-12-30

2.  Comparison of ring artifact removal methods using flat panel detector based CT images.

Authors:  Emran M Abu Anas; Jae G Kim; Soo Y Lee; K Hasan
Journal:  Biomed Eng Online       Date:  2011-08-17       Impact factor: 2.819

3.  John's Equation-based Consistency Condition and Corrupted Projection Restoration in Circular Trajectory Cone Beam CT.

Authors:  Jianhui Ma; Shuyu Wu; Hongliang Qi; Bin Li; Hao Yan; Linghong Zhou; Yuan Xu
Journal:  Sci Rep       Date:  2017-07-07       Impact factor: 4.379

4.  Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density.

Authors:  Hugo Gaêta-Araujo; Eduarda Helena Leandro Nascimento; Danieli Moura Brasil; Daniela Verardi Madlum; Francisco Haiter-Neto; Christiano Oliveira-Santos
Journal:  Imaging Sci Dent       Date:  2020-06-18

5.  Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems.

Authors:  Jakub Šalplachta; Tomáš Zikmund; Marek Zemek; Adam Břínek; Yoshihiro Takeda; Kazuhiko Omote; Jozef Kaiser
Journal:  Sensors (Basel)       Date:  2021-01-01       Impact factor: 3.576

6.  Identification of a unique cause of ring artifact seen in computed tomography trans-axial images.

Authors:  Ashish Kumar Jha; Nilendu C Purandare; Sneha Shah; Archi Agrawal; Ameya D Puranik; Venkatesh Rangarajan
Journal:  Indian J Nucl Med       Date:  2013-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.