Literature DB >> 21512050

Reliability of renal length measurements made with ultrasound compared with measurements from helical CT multiplanar reformat images.

David B Larson1, Mariana L Meyers, Sara M O'Hara.   

Abstract

OBJECTIVE: The purpose of this article is to determine the reliability of sonographic renal length measurements compared with measurements obtained from helical CT multiplanar reformat images and compared with standard renal growth curves.
MATERIALS AND METHODS: A retrospective review was performed of 76 subjects who underwent both renal ultrasound and abdominal CT within 2 weeks of one another. Renal lengths were measured using oblique coronal reformat images of helically acquired CT data by two observers on two occasions. Intraobserver and interobserver error for these measurements were calculated. Ultrasound renal length measurements were compared with CT measurements. Measurement variation was compared with standard renal growth curves.
RESULTS: The mean (± SD) of the absolute value of interobserver error of CT measurements was 0.9 ± 0.8 mm. Compared with CT, individual ultrasound measurements underestimated renal length by 1.5 ± 5.6 mm on average, with a 95% CI of -12.5 to 9.5 mm. When the maximum of three ultrasound renal length measurements was used, the SD was 4.7 mm, with a 95% CI of -8.2 to 10.1 mm of the reported renal length. This corresponds to greater or less than 3.3 years of normal renal growth.
CONCLUSION: Lack of renal growth can be asserted only when renal length falls below the growth curve, taking into account the corresponding measurement error limits, which we found to be greater or less than 9.3 mm. If the follow-up measurement falls within these limits, one should not infer lack of appropriate renal growth, even if the renal length measurement decreases or remains unchanged for up to 3 years.

Entities:  

Mesh:

Year:  2011        PMID: 21512050     DOI: 10.2214/AJR.10.5486

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

1.  Length and volume of morphologically normal kidneys in korean children: ultrasound measurement and estimation using body size.

Authors:  Jun-Hwee Kim; Myung-Joon Kim; Sok Hwan Lim; Jieun Kim; Mi-Jung Lee
Journal:  Korean J Radiol       Date:  2013-07-17       Impact factor: 3.500

2.  MRI-based reference range for the renal pelvis anterior-posterior diameter in children ages 0-19 years.

Authors:  Anthony J Schaeffer; Michael P Kurtz; Tanya Logvinenko; Michael T McCartin; Sanjay P Prabhu; Caleb P Nelson; Jeanne S Chow
Journal:  Br J Radiol       Date:  2016-09-29       Impact factor: 3.039

3.  A step-by-step regressed pediatric kidney depth formula validated by a reasonable index.

Authors:  Si Hongwei; Chen Yingmao; Li Li; Ma Guangyu; Shen Liuhai; Wu Zhifang; Shao Mingzhe; Li Sijin
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

Review 4.  Errors in the ultrasound diagnosis of the kidneys, ureters and urinary bladder.

Authors:  Andrzej Paweł Wieczorek; Magdalena Maria Woźniak; Janusz F Tyloch
Journal:  J Ultrason       Date:  2013-09-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.