Literature DB >> 21511925

High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis.

B J R F Bolland1, D J Culliford, D J Langton, J P S Millington, N K Arden, J M Latham.   

Abstract

This study reports the mid-term results of a large-bearing hybrid metal-on-metal total hip replacement in 199 hips (185 patients) with a mean follow-up of 62 months (32 to 83). Two patients died of unrelated causes and 13 were lost to follow-up. In all, 17 hips (8.5%) have undergone revision, and a further 14 are awaiting surgery. All revisions were symptomatic. Of the revision cases, 14 hips showed evidence of adverse reactions to metal debris. The patients revised or awaiting revision had significantly higher whole blood cobalt ion levels (p = 0.001), but no significant difference in acetabular component size or position compared with the unrevised patients. Wear analysis (n = 5) showed increased wear at the trunnion-head interface, normal levels of wear at the articulating surfaces and evidence of corrosion on the surface of the stem. The cumulative survival rate, with revision for any reason, was 92.4% (95% confidence interval 87.4 to 95.4) at five years. Including those awaiting surgery, the revision rate would be 15.1% with a cumulative survival at five years of 89.6% (95% confidence interval 83.9 to 93.4). This hybrid metal-on-metal total hip replacement series has shown an unacceptably high rate of failure, with evidence of high wear at the trunnion-head interface and passive corrosion of the stem surface. This raises concerns about the use of large heads on conventional 12/14 tapers.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21511925     DOI: 10.1302/0301-620X.93B5.26309

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  76 in total

1.  Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.

Authors:  Adolph V Lombardi; Keith R Berend; Michael J Morris; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2014-11-04       Impact factor: 4.176

2.  CORR Insights(®): Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.

Authors:  Philip C Noble
Journal:  Clin Orthop Relat Res       Date:  2015-08-21       Impact factor: 4.176

3.  Squeaking: Current knowledge and how to avoid it.

Authors:  Arjuna M Imbuldeniya; Simon J Pearce; William L Walter; Bernard A Zicat; William K Walter
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

4.  Neck-preserving femoral stems.

Authors:  Karthig Rajakulendran; Richard E Field
Journal:  HSS J       Date:  2012-09-07

5.  Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

Authors:  Michael B Cross; Denis Nam; David J Mayman
Journal:  HSS J       Date:  2012-09-13

6.  Taper design affects failure of large-head metal-on-metal total hip replacements.

Authors:  Nader A Nassif; Danyal H Nawabi; Kirsten Stoner; Marcella Elpers; Timothy Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

7.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

8.  Metal-on-metal hip prostheses: correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream.

Authors:  Dalila De Pasquale; Susanna Stea; Stefano Squarzoni; Barbara Bordini; Marilina Amabile; Simona Catalani; Pietro Apostoli; Aldo Toni
Journal:  Int Orthop       Date:  2014-03       Impact factor: 3.075

9.  Diagnosis and Management of Adverse Reactions to Metal Debris.

Authors:  Richard A Wawrose; Kenneth L Urish
Journal:  Oper Tech Orthop       Date:  2019-10-01

10.  Accelerating sequences in the presence of metal by exploiting the spatial distribution of off-resonance.

Authors:  Matthew R Smith; Nathan S Artz; Kevin M Koch; Alexey Samsonov; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-01-15       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.