Literature DB >> 21511226

Randomized comparison of a polymer-free sirolimus-eluting stent versus a polymer-based paclitaxel-eluting stent in patients with diabetes mellitus: the LIPSIA Yukon trial.

Steffen Desch1, Denis Schloma, Sven Möbius-Winkler, Sandra Erbs, Stephan Gielen, Axel Linke, Jiangtao Yu, Bernward Lauer, Klaus Kleinertz, Wilfried Dänschel, Gerhard Schuler, Holger Thiele.   

Abstract

OBJECTIVES: The objective of the study was to assess noninferiority of the polymer-free sirolimus-eluting Yukon Choice stent (Translumina GmbH, Hechingen, Germany) compared with the polymer-based Taxus Liberté stent (Boston Scientific, Natick, Massachusetts) with regard to the primary endpoint, in-stent late lumen loss, at 9 months in patients with diabetes mellitus.
BACKGROUND: The Yukon Choice stent has been evaluated in several randomized controlled trials before, albeit to date, there has been no trial that exclusively enrolled patients with diabetes mellitus.
METHODS: Patients with diabetes mellitus undergoing percutaneous coronary intervention for clinically significant de novo coronary artery stenosis were randomized 1:1 to receive either the polymer-free sirolimus-eluting Yukon Choice stent or the polymer-based paclitaxel-eluting Taxus Liberté stent.
RESULTS: A total of 240 patients were randomized. Quantitative coronary angiography was available for 79% of patients. Mean in-stent late lumen loss was 0.63 ± 0.62 mm for the Yukon Choice stent and 0.45 ± 0.60 mm for the Taxus Liberté stent. Based on the pre-specified margin, the Yukon Choice stent failed to show noninferiority for the primary endpoint. During follow-up, there were no significant differences between groups regarding death, myocardial infarction, stent thrombosis, target lesion revascularization, target vessel revascularization, or nontarget vessel revascularization.
CONCLUSIONS: Compared with the Taxus Liberté stent, the polymer-free sirolimus-eluting Yukon Choice stent failed to show noninferiority with regard to the primary endpoint, in-stent late lumen loss, in patients with diabetes mellitus after 9-month follow-up. Both stents showed comparable clinical efficacy and safety. (Yukon Choice Versus Taxus Liberté in Diabetes Mellitus; NCT00368953).
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21511226     DOI: 10.1016/j.jcin.2010.11.016

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  6 in total

Review 1.  Percutaneous coronary intervention: balloons, stents and scaffolds.

Authors:  Roisin Colleran; Adnan Kastrati
Journal:  Clin Res Cardiol       Date:  2018-07-23       Impact factor: 5.460

Review 2.  Polymer-Free Drug-Coated Coronary Stents in Patients with Stable Coronary Artery Disease at High Bleeding Risk.

Authors:  Hemang B Panchal; Ramesh Daggubati; David Zhao; Sunil V Rao; Timir Paul
Journal:  Curr Cardiol Rep       Date:  2017-02       Impact factor: 2.931

Review 3.  Stent thrombosis and adverse cardiovascular outcomes observed between six months and five years with sirolimus-eluting stents and other drug-eluting stents in patients with Type 2 diabetes mellitus complicated by coronary artery disease: A systematic review and meta-analysis.

Authors:  Pravesh Kumar Bundhun; M Zafooruddin Sani Soogund; Manish Pursun; Meng-Hua Chen
Journal:  Medicine (Baltimore)       Date:  2016-07       Impact factor: 1.889

4.  Polymer-free drug-eluting stents versus permanent polymer drug-eluting stents: An updated meta-analysis.

Authors:  Yun-Lin Chen; Jinqi Fan; Guozhu Chen; Li Cao; Li Lu; Yanping Xu; Yuehui Yin
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

5.  Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis.

Authors:  Eliano P Navarese; Kenneth Tandjung; Bimmer Claessen; Felicita Andreotti; Mariusz Kowalewski; David E Kandzari; Dean J Kereiakes; Ron Waksman; Laura Mauri; Ian T Meredith; Aloke V Finn; Hyo-Soo Kim; Jacek Kubica; Harry Suryapranata; Toni Mustahsani Aprami; Giuseppe Di Pasquale; Clemens von Birgelen; Elvin Kedhi
Journal:  BMJ       Date:  2013-11-06

Review 6.  Is There Any Significant Difference in Stent Thrombosis Between Sirolimus and Paclitaxel Eluting Stents?: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

Authors:  Pravesh Kumar Bundhun; Zi Jia Wu; Meng-Hua Chen
Journal:  Medicine (Baltimore)       Date:  2016-02       Impact factor: 1.889

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.