Literature DB >> 21505639

Hand numbness and carpal tunnel syndrome after volar plating of distal radius fracture.

Angela Wing Hang Ho1, S T Ho, S C Koo, K H Wong.   

Abstract

We report the incidence of late onset post-operative carpal tunnel syndrome (late carpal tunnel syndrome) and late median nerve neuropathy after volar plating of distal radius fracture by conducting a retrospective study on volar plating for distal radius fracture performed during 2002 to 2006. Two hundred eighty-two volar plating were performed for acute distal radius fracture after exclusion. Post-operative hand numbness occurred in 24 patients of which nine had carpal tunnel syndrome. Thus, the incidence of late carpal tunnel syndrome was 3.2% (9/282). Of the eight (8/24, 33%) patients with post-operative hand numbness that failed to respond to conservative treatment, five had carpal tunnel release and three had neurolysis of median nerve at distal forearm. All had clinical improvement except in one patient. The incidence of late carpal tunnel syndrome after volar plating of distal radius in the present series is similar to the prevalence of carpal tunnel syndrome in general population. The incidence is low compared with other series, regardless of treatment method (conservative treatment, volar or dorsal plating). The outcome of post-operative hand numbness is generally favourable.

Entities:  

Keywords:  Carpal tunnel syndrome; Distal radius fracture; Median nerve neuropathy; Treatment outcome; Volar plate

Year:  2010        PMID: 21505639      PMCID: PMC3041874          DOI: 10.1007/s11552-010-9283-7

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


Introduction

Open reduction and internal fixation is becoming more popular with the emphasis on alignment for good functional recovery, and it is more ready to fix unstable fractures. Dorsal plating has high incidence of extensor tendon complications [11], while volar plating has less soft tissue complications. The recent development of locking distal radius plate has increased in open reduction with internal fixation in volar approach. Such volar locking plate is also useful in the treatment of dorsally displaced distal radius fracture and comminuted osteoporotic intra-articular fracture. The incidence of median nerve complication is of particular concern in volar plating for distal radius fracture. In this study, we report the incidence of hand numbness, carpal tunnel syndrome and outcome of median nerve neuropathy after volar plating of distal radius fracture.

Method and Materials

This is a retrospective review of all volar plating performed for distal radius fracture from January 2002 to December 2006 in two regional hospitals in Hong Kong. The volar distal radius was approached through the sheath of the flexor carpi radialis tendon. Choice of implant (3.5-mm T-shaped locking plate and non-locking plate) depended on fracture pattern. In general, locking plates were use in intra-articular, dorsally displaced fracture or osteoporotic fracture. Non-locking plates were use in extra-articular or volarly displaced fracture. We searched the electronic database using keywords of distal radius fracture, open reduction and internal fixation of radius fracture, carpal tunnel release or neurolysis. We also reviewed all medical notes (hospital and out-patient clinic record), operative records and radiographs. The inclusion criteria were age 18 or above, distal radius fracture with volar plating performed. The exclusion criteria were pre-existing carpal tunnel syndrome before injury, carpal tunnel release at index operation due to compartment syndrome or as part of surgical approach during open reduction and plating. These patients were having more high-energy trauma, which may cause injury to median nerve. Patients were reviewed in the specialist out-patient clinic by orthopaedic team members, which ranged from 1 to 5 years. Symptoms of hand numbness, wrist pain, signs of carpal tunnel syndrome such as Phalen’s test, Tinel sign and thenar wasting were noted. Results of nerve conduction study are also noted. Union of fracture was assessed by serial radiograph. All patients that complained of hand numbness were noted. Patient with post-operative hand numbness were divided into two groups. We defined late carpal tunnel syndrome based on symptomatology or electrophysiological study. Patients who had numbness over median nerve territory (radial three and a half digits), and one of the positive signs (Tinel sign, Phalen’s test or thenar wasting) of carpal tunnel syndrome, or confirmed by nerve conduction test were included in late carpal tunnel syndrome group. Patients with numbness not in median nerve territory or with forearm involvement were regarded to have late median nerve neuropathy due to scarring over forearm surgical wound. Statistical analysis was performed by using SPSS software. One-sided Fisher’s exact test was used to compare the hand numbness and carpal tunnel syndrome after volar plating with locking plate and non-locking plate.

Result

A total of 300 volar plating of distal radius were performed in the specified period. Eighteen fractures were excluded: one distal radius fracture nonunion, six pre-existing carpal tunnel syndrome before fracture (a patient with bilateral wrist fracture), five primary carpal tunnel release as part of surgical exposure and another six primary carpal tunnel release at the index operation (three for acute carpal tunnel syndrome and three for compartment syndrome). After exclusion, a total of 282 patients were included for analysis of post-operative hand numbness. There were 99 males and 183 females, with age that ranged from 24 to 90. Two hundred sixteen locking plates were performed for intra-articular fracture or osteoporotic fracture. Sixty-six non-locking plates were performed for extra-articular fracture. Of the 282 patients, 24 had post-operative hand numbness after volar plating. None of these 24 patients have diabetes mellitus, thyroid disorder, renal failure, etc. as risk factor of neuropathy. Within this group, nine patients had late carpal tunnel syndrome, and 15 patients had late median nerve neuropathy. In summary, the incidence of all post-operative hand numbness was 8.5% (24/282), late carpal tunnel syndrome was 3.2% (9/282), and late median nerve neuropathy was 5.3% (15/282). The incidence of late carpal tunnel syndrome in female and male were 3.3% and 3%, respectively. The detail breakdown of age and sex with respect to the late carpal tunnel syndrome is shown in Table 1. The incidence of all post-operative hand numbness in locking plate group was significantly higher (p < 0.05) than that of the non-locking plate—10.2% (22/216) vs. 3.03% (2/66). The incidence of late carpal tunnel syndrome after volar plating with locking plate was 4.17% (9/216), while no carpal tunnel syndrome was noted in the group of volar plating with non-locking plate; but, this was statistically insignificant (0.1 > p > 0.05).
Table 1

Age and sex breakdown of result.

AgeVolar platingLate carpal tunnel syndrome
FemaleMaleFemaleMale
<251900%00%
25–343400%00%
35–4481600%16.3%
45–54423812.4%00%
55–64361738.3%211.8%
65–74561123.6%00%
75 or above37400%00%
Total1839963.3%33.0%
Age and sex breakdown of result. Of the 24 patients with post-operative hand numbness, 16 (66.7%) patients responded to conservative treatment (splintage, vitamin supplement or regular observation), and eight (33.3%) patients had operations (five had carpal tunnel release and three had neurolysis of median nerve without carpal tunnel release). After operation, seven patients had improvement of symptoms. For patient with late carpal tunnel syndrome characterised by specific signs and symptoms or nerve conduction study confirmed, four patients responded to conservative treatment (splintage, vitamin supplement or regular observation), and five patients received operative treatment. Intra-operative findings showed carpal tunnel narrowing and constriction of the median nerve. Carpal tunnel release was performed, and all patients had improvement except one patient who had electrophysiological suggestions of bilateral carpal tunnel syndrome on nerve conduction test and inappropriate illness behaviour shown in functional capacity evaluation (Table 2).
Table 2

Summary of operative treatment for late carpal tunnel syndrome.

Sex/ageFracture classification (AO)Onset interval (month)PresentationCarpal tunnel release, operative findingsOutcome
F/68A32Hand numbness and wastingScar adhesionImproved
M/61C22Hand numbness and weakness, delay NCVScar adhesion, carpal tunnel constrictionImproved
M/41C13Bilateral CTS in NCTNarrow carpal tunnelSame
F/60A37Specific hand numbnessCarpal tunnel constrictionImproved
F/66C22Specific hand numbnessCarpal tunnel constrictionImproved
Summary of operative treatment for late carpal tunnel syndrome. For patient with late median nerve neuropathy characterised by numbness over hand with or without forearm involvement, three out of 15 patients received operative treatment. All had scar adhesion over median nerve in forearm region. All improved after neurolysis of median nerve without carpal tunnel release and removal of implant except one patient who had residual numbness over middle finger (Table 3).
Table 3

Summary of operative treatment for late median nerve neuropathy.

Sex/ageFracture classificationOnset interval (months)PresentationNeurolysis OT findingsOutcome
F/40C22Wrist numbnessScar adhesionImproved
F/57C22Palm numbnessScar adhesionImproved
F/57A17Wrist numbnessScar adhesionImproved

NCV nerve conduction velocity, NCT nerve conduction test, CTS carpal tunnel syndrome

Summary of operative treatment for late median nerve neuropathy. NCV nerve conduction velocity, NCT nerve conduction test, CTS carpal tunnel syndrome

Discussion

The incidence of late carpal tunnel syndrome after volar plating reported in our series was 3.2%. In literature, the incidence of carpal tunnel syndrome with conservative treatment for distal radius fracture was reported as 7%, which ranged from 0% to 20% [1, 3, 4, 9, 16, 20, 22, 23] (Table 4). There are few papers in recent literature concerning carpal tunnel syndrome after volar plating of distal radius fracture. The average incidence after volar plating was 10.1%, which ranged from 0% to 23% [10, 12–18, 21]. The sample size of these series ranged from 17 to 69, which is much smaller than 282 in our series. The incidence of late carpal tunnel syndrome reported in our series was 3.2%, which is lower than other similar series. The pathophysiology of carpal tunnel syndrome after distal radius fracture has been studied by various authors [5, 7, 8, 19]. Causes include oedema and haematoma from injury, local anaesthetic solution injection, closed reduction and manipulation, flexion position of the wrist and surgical trauma from surgery. Prevalence of carpal tunnel syndrome in general population was reported as 3.8% [2]. The incidence of late carpal tunnel syndrome after volar plating reported in our series was 3.2%. Thus, the incidence of late carpal tunnel syndrome after volar plating is similar to general population reported (Table 5).
Table 4

Incidence of carpal tunnel syndrome in different treatment method of distal radius fracture.

AuthorCTSSampleCTS incidence (%)
Conservative treatment of distal radius fracture
 Cooney [4]405657
 Stewart [19]2520912
 Aro [1]141668.4
 Hove [9]235424.2
 Young [21]32512
 Young [22]0500
 Bienek [3]126020
 Total11716177
Volar plating of distal radius fracture
 Mehara [13]43910
 Jupiter [12]64912
 Zoubos [23]0350
 Hove [10]0310
 Odumala [15]176923
 Musgrave [14]2326
 Wong [20]23013
 Ruch [17]21714
 Total3332610.1
Dorsal plating of distal radius fracture
 Fawzy [6]17

LP locking plate, CTS carpal tunnel syndrome

Table 5

Prevalence of carpal tunnel syndrome in general population compare with current study.

General population [2]Study population
Pain, numbness or tingling (%)Clinically certain (%)Clinically and NCT confirmed (%)Overall (%)
Women17.34.63.04.63.3% (6/183)
Men10.42.82.12.83.2% (3/99)
Total14.43.82.73.83.2% (9/282)
Incidence of carpal tunnel syndrome in different treatment method of distal radius fracture. LP locking plate, CTS carpal tunnel syndrome Prevalence of carpal tunnel syndrome in general population compare with current study. In our study, there is a statistically significant higher incidence of post-operative hand numbness and a trend of higher incidence of carpal tunnel syndrome after volar plating using locking plate compared with using non-locking plate. This may due to more distal position of locking plate, which are often used in intra-articular fracture. The retraction of tissue when putting this distally placed locking plate can also cause median nerve paresthesia (Table 6).
Table 6

Incidence of all post-operative hand numbness and carpal tunnel syndrome in different plate.

Locking plateNon-locking plate p value
All post-operative hand numbness2210.2%23.03%0.049
Carpal tunnel syndrome94.17%00%0.087
Total21666
Incidence of all post-operative hand numbness and carpal tunnel syndrome in different plate. Besides carpal tunnel syndrome, neuropathy arising from scar adhesion of median nerve at the surgical wound will also cause post-operative hand numbness. The outcome of operative treatment for carpal tunnel syndrome or median nerve neuropathy from scar adhesion is generally favourable. The limitations of the current study are as follows. It is not a prospective randomised control study. The operation and follow-up assessment was performed by different surgeons, and the interval of follow-up was not standardised. Outcome measurement is mainly based on patient symptomatology, and not all patients have electrophysical assessment.

Conclusion

The result from our study showed that the incidence of late carpal tunnel syndrome after volar plating of distal radius fracture is similar to general population. The incidence is lower than that previously reported in other series of distal radius fracture, regardless of the treatment method (conservative treatment, open reduction and plating). Post-operative hand numbness has a favourable outcome as shown in our study; 66.7% (16/24) patients respond to conservative treatment, and of the eight that required carpal tunnel release or neurolysis of median nerve, only one did not have their symptoms improved.
  14 in total

1.  Compartment pressure in the carpal tunnel in distal fractures of the radius. A prospective study.

Authors:  K Dresing; T Peterson; K P Schmit-Neuerburg
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

2.  Outcome following nonoperative treatment of displaced distal radius fractures in low-demand patients older than 60 years.

Authors:  B T Young; G M Rayan
Journal:  J Hand Surg Am       Date:  2000-01       Impact factor: 2.230

3.  The hand complications of Colles' fractures.

Authors:  H D Stewart; A R Innes; F D Burke
Journal:  J Hand Surg Br       Date:  1985-02

4.  Tissue pressure threshold for peripheral nerve viability.

Authors:  R H Gelberman; R M Szabo; R V Williamson; A R Hargens; N C Yaru; M A Minteer-Convery
Journal:  Clin Orthop Relat Res       Date:  1983-09       Impact factor: 4.176

5.  Open reduction and internal fixation of distal radial fractures using the Pi-plate.

Authors:  Ernest A Fawzy; Konstantinos T Kateros; Panayiotis J Papagelopoulos; George S Themistocleous; Ramesh J Chennangiri; Nicholas R Gillham
Journal:  Injury       Date:  2005-02       Impact factor: 2.586

6.  Prophylactic carpal tunnel decompression during buttress plating of the distal radius--is it justified?

Authors:  O Odumala; C Ayekoloye; G Packer
Journal:  Injury       Date:  2001-09       Impact factor: 2.586

7.  Surgical treatment of 35 volar Barton fractures. No need for routine decompression of the median nerve.

Authors:  A B Zoubos; G C Babis; D S Korres; T Pantazopoulos
Journal:  Acta Orthop Scand Suppl       Date:  1997-10

8.  Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates.

Authors:  Douglas S Musgrave; Richard S Idler
Journal:  J Hand Surg Am       Date:  2005-07       Impact factor: 2.230

9.  Nerve entrapment and reflex sympathetic dystrophy after fractures of the distal radius.

Authors:  L M Hove
Journal:  Scand J Plast Reconstr Surg Hand Surg       Date:  1995-03

10.  Classification and treatment of volar Barton fractures.

Authors:  A K Mehara; S Rastogi; S Bhan; P K Dave
Journal:  Injury       Date:  1993       Impact factor: 2.586

View more
  6 in total

1.  A Survey of the Median Nerve Elasticity after Volar Locking Plate Fixation Using Ultrasound Elastography.

Authors:  Yoichi Sugiyama; Kiyohito Naito; Hideaki Miyamoto; Kenji Goto; Mayuko Kinoshita; Nana Nagura; Yoshiyuki Iwase; Kazuo Kaneko
Journal:  J Hand Microsurg       Date:  2019-04-23

Review 2.  Distal radius fractures in the athlete.

Authors:  Casey Beleckas; Ryan Calfee
Journal:  Curr Rev Musculoskelet Med       Date:  2017-03

3.  Differences in the Treatment of Distal Radius Fractures by Hand Fellowship Trained Surgeons: A Study of ABOS Candidate Data.

Authors:  Sean Childs; Tobias Mann; Jason Dahl; John Ketz; Warren C Hammert; Peter M Murray; John Elfar
Journal:  J Hand Surg Am       Date:  2016-12-24       Impact factor: 2.230

4.  Comparison of Risk of Carpal Tunnel Syndrome in Patients with Distal Radius Fractures After 7 Treatments.

Authors:  Huan-Li Zhao; Gui-Bin Wang; Yue-Qing Jia; Shi-Cai Zhu; Feng-Fang Zhang; Hong-Mei Liu
Journal:  Med Sci Monit       Date:  2015-09-22

5.  Changes in Nerve Conduction Studies After Distal Radius Fracture Fixation Using a Volar Approach and Locked Plate.

Authors:  Cory Demino; Anne E Argenta; Gabriella Dibernardo; Kia Washington; Robert J Goitz; John R Fowler
Journal:  J Hand Surg Glob Online       Date:  2020-07-11

6.  Neurologic complications in common wrist and hand surgical procedures.

Authors:  Nicole Verdecchia; Julie Johnson; Mark Baratz; Steven Orebaugh
Journal:  Orthop Rev (Pavia)       Date:  2018-03-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.