Literature DB >> 16039367

Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates.

Douglas S Musgrave1, Richard S Idler.   

Abstract

PURPOSE: To determine whether volar fixed-angle plate fixation with a new plate system could be used to treat dorsally unstable distal radius fractures. We hypothesized that volar fixed-angle plate fixation with or without radial styloid fixed-angle plate fixation would provide sufficient rigidity to allow early active range of motion without compromising fracture reduction. The initiation of early active motion may improve functional outcomes.
METHODS: A retrospective review was conducted of one institution's initial experience using a new volar fixed-angle plate system to treat dorsally displaced intra-articular and extra-articular distal radius fractures. Thirty-two fractures in 32 patients with dorsally displaced distal radius fractures were treated with a volar fixed-angle plate with or without a radial styloid fixed-angle plate. Fractures were classified using the AO classification. Radiographic parameters on preoperative, postoperative, and final follow-up radiographs were compared. The time to initiation of active range of motion was determined. Final follow-up ranges of motion and complications were reported. Finally, comparisons were made between the 23 fractures treated with a volar plate alone and the 9 fractures treated with a volar plate and a radial styloid plate.
RESULTS: The average follow-up period was 13 months. Two thirds of the fractures were intra-articular. Average loss of reduction from initial postoperative to final follow-up radiographs was 0 degrees of volar tilt, 1 degrees of radial inclination, and 0 mm of radial length. Active wrist and forearm ranges of motion were initiated at an average of 11 days after surgery. The final follow-up flexion-extension and pronation-supination arcs averaged 112 degrees and 151 degrees , respectively. The 9 fractures treated with the combination of a fixed-angle volar plate with a fixed-angle radial styloid plate had greater initial displacement than did the 23 fractures treated with a volar plate alone. Otherwise, differences between the 2 groups were not significant. Only 1 radial styloid plate became symptomatic.
CONCLUSIONS: Volar plate fixation using a new fixed-angle plate system successfully can stabilize dorsally unstable distal radius fractures. Early active range of motion was facilitated without compromising fracture reduction.

Entities:  

Mesh:

Year:  2005        PMID: 16039367     DOI: 10.1016/j.jhsa.2005.03.006

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  23 in total

1.  Anatomical and radiological study applied to distal radius surgery.

Authors:  N Gasse; D Lepage; R Pem; C Bernard; J M Lerais; P Garbuio; L Obert
Journal:  Surg Radiol Anat       Date:  2010-12-07       Impact factor: 1.246

2.  Volar locking plate fixation of distal radius fractures: use of an intra-operative 'carpal shoot through' view to identify dorsal compartment and distal radioulnar joint screw penetration.

Authors:  Daniel Marsland; Chris M Hobbs; Philip S Sauvé
Journal:  Hand (N Y)       Date:  2014-12

3.  Distal radius osteotomy with volar locking plates based on computer simulation.

Authors:  Junichi Miyake; Tsuyoshi Murase; Hisao Moritomo; Kazuomi Sugamoto; Hideki Yoshikawa
Journal:  Clin Orthop Relat Res       Date:  2011-01-04       Impact factor: 4.176

4.  Volar locking plate fixation for distal radius fractures: Does age affect outcome?

Authors:  Ahmed Ezzat; Santosh Baliga; Carol Carnegie; Alan Johnstone
Journal:  J Orthop       Date:  2016-02-22

5.  Volar plate fixation of intra-articular distal radius fractures: a retrospective study.

Authors:  Margaret W M Fok; Melissa A Klausmeyer; Diego L Fernandez; Jorge L Orbay; Alex Lluch Bergada
Journal:  J Wrist Surg       Date:  2013-08

6.  [Fixation of distal radial fractures with the Targon DR nail].

Authors:  Georg Gradl; Martina Wendt; Philip Gierer; Markus Beck; Thomas Mittlmeier
Journal:  Oper Orthop Traumatol       Date:  2009-11       Impact factor: 1.154

7.  Fixed-angle volar plate fixation for distal radius fractures in immunosuppressed patients.

Authors:  Erik D Peterson; David G Dennison
Journal:  Hand (N Y)       Date:  2008-04-30

8.  Comparison of locked volar plating versus pinning and external fixation in the treatment of unstable intraarticular distal radius fractures.

Authors:  Marco Rizzo; Brian A Katt; Joshua T Carothers
Journal:  Hand (N Y)       Date:  2007-10-17

9.  External fixation of fractures of the distal radius: a randomized comparison of the Hoffman compact II non-bridging fixator and the Dynawrist fixator in 75 patients followed for 1 year.

Authors:  Yngvar Krukhaug; Stein Ugland; Stein A Lie; Leiv M Hove
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

10.  Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: a randomized study of 50 patients.

Authors:  Antonio Abramo; Philippe Kopylov; Mats Geijer; Magnus Tägil
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

View more