Measurement of aortic valve annulus using different cardiac imaging techniques in transcatheter aortic valve implantation: agreement with finally implanted prosthesis size.

Dolores Mesa Rubio1, José Suárez de Lezo Cruz Conde, Manuel Pan Alvarez-Osorio, Martin Ruiz Ortiz, Mónica Delgado Ortega, Maria del Carmen León del Pino, Francisco Toledano Delgado, Jose Segura Saint-Gerons, Soledad Ojeda Pineda, Daniel Garcia Fuertes, Manuel Crespín Crespín, Simona Espejo, Rusel Ysamat.   

Abstract

AIMS: To compare the measurements of the aortic annulus obtained with various imaging techniques in patients with severe aortic stenosis scheduled for transcatheter aortic valve implantation, and to determine the grade of agreement between the predicted size of the prosthesis for each technique, and the size of the finally implanted valve. METHODS AND
RESULTS: The aortic annulus was measured in 40 patients treated by transcatheter aortic valve implantation (CoreValve aortic valve) with transthoracic (TTE) and transesophageal echocardiography (TEE), 64-slice tomography, and angiography. A large valve was implanted when annulus was >23 mm and a small one if it was ≤23 mm. If the size of the prosthesis predicted by several techniques was not the same in one case, we selected the size in which more techniques presented agreement. Forty aortic valves, 26 small and 14 large, were implanted percutaneously. The best correlation was obtained with TTE and TEE (r = 0.93, P < 0.001). The correlation of TTE and TEE with angiography also was good (r = 0.58, P < 0.001 and r = 0.53, P < 0.001, respectively). Correlations between these techniques and computed tomography were poor (P = NS for all comparisons). The best agreement between estimated aortic annulus and implanted valve size was obtained with transtoracic and TEE (κ= 0.88 and 0.76).
CONCLUSIONS: The aortic annulus measurements obtained by TTE, TEE, and angiography correlated well, while tomography correlated poorly with other techniques. The imaging techniques that showed the best agreement between estimated aortic annulus size and implanted aortic valve size were TTE and TEE.
© 2011, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21504463     DOI: 10.1111/j.1540-8175.2010.01353.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Proximal thoracic aortic diameter measurements at CT: repeatability and reproducibility according to measurement method.

Authors:  Leslie E Quint; Peter S Liu; Anna M Booher; Kuanwong Watcharotone; James D Myles
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-03       Impact factor: 2.357

2.  Comparison of aortic annulus diameter measurement between multi-detector computed tomography and echocardiography: a meta-analysis.

Authors:  Ruifang Zhang; Yi Song; Yuanyuan Zhou; Lulu Sun
Journal:  PLoS One       Date:  2013-03-14       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.