Partial ring artifact on cardiac CT: image presentation and clinical implication.

Hsin-Yu Tsai1, Min-Chi Chen, I-Chen Tsai, Clayton Chi-Chang Chen.   

Abstract

In computed tomography (CT), the term "artifact" is applied to any systematic discrepancy between the CT numbers in the reconstructed image and the true attenuation coefficients of the object. A partial ring artifact in cardiac CT has a unique pattern and has not been previously reported in real clinical practice. In this report, we will demonstrate the images and animations of a cardiac CT which is affected by a partial ring artifact due to a broken detector module. The different characteristics of ring artifacts on routine and cardiac CT, and the implications for clinical interpretation will also be described. In summary, when a partial ring artifact is noted incidentally on cardiac CT, we suggest interpreting the images by reviewing reconstructed images from different RR-intervals to avoid unnecessary repeated scans and additional radiation exposure.

Mesh:

Substances:

Year:  2011        PMID: 21503707     DOI: 10.1007/s10554-011-9862-x

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  5 in total

1.  High-pitch spiral acquisition: a new scan mode for coronary CT angiography.

Authors:  Stephan Achenbach; Mohamed Marwan; Tiziano Schepis; Tobias Pflederer; Herbert Bruder; Thomas Allmendinger; Martin Petersilka; Katharina Anders; Michael Lell; Axel Kuettner; Dieter Ropers; Werner G Daniel; Thomas Flohr
Journal:  J Cardiovasc Comput Tomogr       Date:  2009-02-26

Review 2.  Comprehensive evaluation of ischemic heart disease using MDCT.

Authors:  I-Chen Tsai; Wen-Lieng Lee; Chen-Rong Tsao; Yen Chang; Min-Chi Chen; Tain Lee; Wan-Chun Liao
Journal:  AJR Am J Roentgenol       Date:  2008-07       Impact factor: 3.959

3.  Measurement of temporal resolution in dual source CT.

Authors:  Cynthia H McCollough; Bernhard Schmidt; Lifeng Yu; Andrew Primak; Stefan Ulzheimer; Herbert Bruder; Thomas G Flohr
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

Review 4.  Physics of cardiac imaging with multiple-row detector CT.

Authors:  Mahadevappa Mahesh; Dianna D Cody
Journal:  Radiographics       Date:  2007 Sep-Oct       Impact factor: 5.333

5.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.