Literature DB >> 21501842

A method to perform spinal motion analysis from functional X-ray images.

Martin Schulze1, Frank Trautwein, Thomas Vordemvenne, Michael Raschke, Frank Heuer.   

Abstract

Identifying spinal instability is an important aim for proper surgical treatment. Analysis of functional X-ray images delivers measurements of the range of motion (RoM) and the center of rotation (CoR). In today's practice, CoR determination is often omitted, due to the lack of accurate methods. The aim of this work was to investigate the accuracy of a new analysis software (FXA™) based on an in vitro experiment. Six bovine spinal specimens (L3-4) were mounted in a robot (KR125, Kuka). CoRs were predefined by locking the robot actuator tool center point to the estimated position of the physiologic CoR and taking a baseline X-ray. Specimens were deflected to various RoM(preset) flexion/extension angles about the CoR(preset). Lateral functional radiographs were acquired and specimen movements were recorded using an optical motion tracking system (Optotrak Certus). RoM and CoR errors were calculated from presets for both methods. Prior to the experiment, the FXA™ software was verified with artificially generated images. For the artificial images, FXA™ yielded a mean RoM-error of 0.01 ± 0.03° (bias ± standard deviation). In the experiment, RoM-error of the FXA™-software (deviation from presets) was 0.04 ± 0.13°, and 0.10 ± 0.16° for the Optotrak, respectively. Both correlated with 0.998 (p < 0.001). For RoM < 1.0°, FXA™ determined CoR positions with a bias>20mm. This bias progressively decreased from RoM = 1° (bias = 6.0mm) to RoM = 9° (bias<1.5mm). Under the assumption that CoR location variances <5mm are clinically irrelevant on the lumbar spine, the FXA™ method can accurately determine CoRs for RoMs > 1°. Utilizing FXA™, polysegmental RoMs, CoRs and implant migration measurements could be performed in daily practice.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21501842     DOI: 10.1016/j.jbiomech.2011.03.040

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Measurement Performance of a Computer Assisted Vertebral Motion Analysis System.

Authors:  Reginald J Davis; David C Lee; Chip Wade; Boyle Cheng
Journal:  Int J Spine Surg       Date:  2015-07-17

2.  Safety and clinical performance of kyphoplasty and SpineJack(®) procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study.

Authors:  D C Noriega; R H Ramajo; I S Lite; B Toribio; R Corredera; F Ardura; A Krüger
Journal:  Osteoporos Int       Date:  2016-02-08       Impact factor: 4.507

3.  Clinical and radiological outcome 1-year after cervical total disc replacement using the Signus ROTAIO - Prosthesis.

Authors:  Anna Lang; Sara Lener; Lukas Grassner; Anto Abramovic; Claudius Thomé; Dennis Päsler; Jens Lehmberg; Ralph Schär; Sebastian Hartmann
Journal:  Eur Spine J       Date:  2022-10-11       Impact factor: 2.721

4.  Radiological and Clinical Outcomes after Anterior Cervical Discectomy and Fusion (ACDF) with an Innovative 3D Printed Cellular Titanium Cage Filled with Vertebral Bone Marrow.

Authors:  Florian Haasters; Christoph Mehren; Frizzi Mayer; Franziska Heider
Journal:  Biomed Res Int       Date:  2022-04-26       Impact factor: 3.246

5.  Comparison of hybrid constructs with 2-level artificial disc replacement and 2-level anterior cervical discectomy and fusion for surgical reconstruction of the cervical spine: a kinematic study in whole cadavers.

Authors:  Baoge Liu; Zheng Zeng; Tom Van Hoof; Jean Pierre Kalala; Zhenyu Liu; Bingxuan Wu
Journal:  Med Sci Monit       Date:  2015-04-08

6.  Surgical Treatment of Multilevel Degenerative Cervical Myelopathy: Open-Door Laminoplasty and Fixation via Unilateral Approach. A Feasibility Study.

Authors:  Gregor Schmeiser; Janina Isabel Bergmann; Luca Papavero; Ralph Kothe
Journal:  J Neurol Surg A Cent Eur Neurosurg       Date:  2021-12-15       Impact factor: 0.984

7.  Clinical Performance and Safety of 108 SpineJack Implantations: 1-Year Results of a Prospective Multicentre Single-Arm Registry Study.

Authors:  David Noriega; Gianluca Maestretti; Christian Renaud; Natale Francaviglia; Mourad Ould-Slimane; Steffen Queinnec; Helmut Ekkerlein; Frank Hassel; Rainer Gumpert; Pascal Sabatier; Hervé Huet; Miguel Plasencia; Nicolas Theumann; Alexander Kunsky; Antonio Krüger
Journal:  Biomed Res Int       Date:  2015-12-30       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.