Reduction in corneal volume with severity of keratoconus.

Luisa Simo Mannion1, Cindy Tromans, Clare O'Donnell.   

Abstract

PURPOSE: To compare the corneal volume in keratoconic and normal eyes to improve our understanding of the tissue distribution associated with the disease. MATERIALS AND
METHOD: The Oculus Pentacam tomographer (Oculus Inc., Wetzlar, Germany) was used to analyze the corneal volume contained within discs with diameters of 3, 5, 7, and 10 mm in 21 patients with keratoconus and 21 matched healthy control subjects.
RESULTS: Corneal volume was significantly decreased in the keratoconus group (keratoconus vs. control group: 3.44 ± 0.39 vs. 4.05 ± 0.29 mm(3), 10.34 ± 0.95 vs. 11.79 ± 0.84 mm(3), 22.80 ± 1.73 vs. 25.26 ± 1.74 mm(3), and 57.17 ± 3.94 vs. 61.90 ± 4.12 mm(3) for the 3-, 5-, 7-, and 10-mm diameter discs, respectively; p < 0.001). As the corneal disc diameter analyzed increased, fewer differences were found between the control corneas and keratoconic corneas at different stages of the disease. Within the 3-mm and 5-mm diameter discs, significant differences were detected between the control group, moderate keratoconus, and the severe keratoconus groups (p < 0.05). However, within the 10-mm discs, differences were only detected between the control group and the severe keratoconus group (p = 0.005).
CONCLUSIONS: Corneal volume was significantly decreased in keratoconus, particularly in the central and paracentral area. The decrease in corneal volume in moderate and severe keratoconus as detected by the Pentacam tomographer, may be explained by loss of corneal tissue. In the early stages of the disease, the altered metabolic activity may cause tissue stretching and, as the disease progresses, this stretching is then accompanied by tissue loss.

Entities:  

Mesh:

Year:  2011        PMID: 21501083     DOI: 10.3109/02713683.2011.553306

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  12 in total

1.  Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

Authors:  Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; Zsuzsa Flasko; Laszlo Modis
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

2.  Corneal thickness and volume in subclinical and clinical keratoconus.

Authors:  Seyed Mahdi Ahmadi Hosseini; Norhani Mohidin; Fereshteh Abolbashari; Bariah Mohd-Ali; Chandramalar T Santhirathelagan
Journal:  Int Ophthalmol       Date:  2012-11-09       Impact factor: 2.031

3.  Topographic characteristics of keratoconus among a sample of Jordanian patients.

Authors:  Mohammed Ali Abu Ameerh; Nathalie Bussières; Ghada Ismail Hamad; Muawyah Dawoud Al Bdour
Journal:  Int J Ophthalmol       Date:  2014-08-18       Impact factor: 1.779

4.  In Vivo Corneal Biomechanical Properties with Corneal Visualization Scheimpflug Technology in Chinese Population.

Authors:  Ying Wu; Lei Tian; Yi-Fei Huang
Journal:  Biomed Res Int       Date:  2016-07-14       Impact factor: 3.411

5.  Identifying more reliable parameters for the detection of change during the follow-up of mild to moderate keratoconus patients.

Authors:  Ivo Guber; Colm McAlinden; François Majo; Ciara Bergin
Journal:  Eye Vis (Lond)       Date:  2017-10-25

6.  Normative values and contralateral comparison of anterior chamber parameters measured by Pentacam and its correlation with corneal biomechanical factors.

Authors:  Mohammad Reza Sedaghat; Vahid Mohammad Zadeh; Kaveh Fadakar; Sakineh Kadivar; Mojtaba Abrishami
Journal:  Saudi J Ophthalmol       Date:  2016-12-01

7.  The corneal volume and biomechanical corneal factors: Is there any orrelation?

Authors:  Mohammad Reza Sedaghat; Maria Sharepoor; Samira Hassanzadeh; Mojtaba Abrishami
Journal:  J Res Med Sci       Date:  2012-01       Impact factor: 1.852

8.  Comparison of Scheimpflug imaging parameters between steep and keratoconic corneas of Caucasian eyes.

Authors:  Tukezban Huseynova; Farah Abdulaliyeva; Michele Lanza
Journal:  Clin Ophthalmol       Date:  2016-04-01

9.  Anterior segment characteristics in normal and keratoconus eyes evaluated with a combined Scheimpflug/Placido corneal imaging device.

Authors:  Masoud Safarzadeh; Nader Nasiri
Journal:  J Curr Ophthalmol       Date:  2016-06-25

10.  Keratoconus Detection Based on a New Corneal Volumetric Analysis.

Authors:  Francisco Cavas-Martínez; Laurent Bataille; Daniel G Fernández-Pacheco; Francisco J F Cañavate; Jorge L Alio
Journal:  Sci Rep       Date:  2017-11-20       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.