Literature DB >> 21500272

Positive visualization of implanted devices with susceptibility gradient mapping using the original resolution.

Gopal Varma1, Rachel E Clough, Peter Acher, Julien Sénégas, Hannes Dahnke, Stephen F Keevil, Tobias Schaeffter.   

Abstract

In magnetic resonance imaging, implantable devices are usually visualized with a negative contrast. Recently, positive contrast techniques have been proposed, such as susceptibility gradient mapping (SGM). However, SGM reduces the spatial resolution making positive visualization of small structures difficult. Here, a development of SGM using the original resolution (SUMO) is presented. For this, a filter is applied in k-space and the signal amplitude is analyzed in the image domain to determine quantitatively the susceptibility gradient for each pixel. It is shown in simulations and experiments that SUMO results in a better visualization of small structures in comparison to SGM. SUMO is applied to patient datasets for visualization of stent and prostate brachytherapy seeds. In addition, SUMO also provides quantitative information about the number of prostate brachytherapy seeds. The method might be extended to application for visualization of other interventional devices, and, like SGM, it might also be used to visualize magnetically labelled cells.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21500272     DOI: 10.1002/mrm.22710

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment.

Authors:  Tze Yee Lim; Rajat J Kudchadker; Jihong Wang; R Jason Stafford; Christopher MacLellan; Arvind Rao; Geoffrey S Ibbott; Steven J Frank
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

2.  A biodistribution and toxicity study of cobalt dichloride-N-acetyl cysteine in an implantable MRI marker for prostate cancer treatment.

Authors:  Steven J Frank; Mary J Johansen; Karen S Martirosyan; Mihai Gagea; Carolyn S Van Pelt; Agatha Borne; Yudith Carmazzi; Timothy Madden
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-10-22       Impact factor: 7.038

3.  Positive visualization of MR-compatible nitinol stent using a susceptibility-based imaging technique.

Authors:  Caiyun Shi; Guoxi Xie; Dong Liang; Haifeng Wang; Yi Huang; Yanan Ren; Yong Xue; Hanwei Chen; Shi Su; Xin Liu
Journal:  Quant Imaging Med Surg       Date:  2019-03

4.  Monitoring of in vivo function of superparamagnetic iron oxide labelled murine dendritic cells during anti-tumour vaccination.

Authors:  Richard Tavaré; Pervinder Sagoo; Gopal Varama; Yakup Tanriver; Alice Warely; Sandra S Diebold; Richard Southworth; Tobias Schaeffter; Robert I Lechler; Reza Razavi; Giovanna Lombardi; Gregory E D Mullen
Journal:  PLoS One       Date:  2011-05-27       Impact factor: 3.240

5.  Radiotherapy planning using MRI.

Authors:  Maria A Schmidt; Geoffrey S Payne
Journal:  Phys Med Biol       Date:  2015-10-28       Impact factor: 3.609

6.  Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients.

Authors:  Alexander Ciritsis; Daniel Truhn; Nienke L Hansen; Jens Otto; Christiane K Kuhl; Nils A Kraemer
Journal:  PLoS One       Date:  2016-05-18       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.