Literature DB >> 2149723

A laser Doppler catheter for monitoring both phasic and mean coronary vein flow.

K Mito1, Y Ogasawara, O Hiramatsu, K Tsujioka, F Kajiya.   

Abstract

A new catheter-type laser Doppler velocimeter has been developed to monitor coronary vein flow. A thin graded-index multimode optical fiber (outer diameter of 125 microns) is set inside a 5-F catheter, and eight elastic silicon rubber spikes are arranged radially toward the vessel wall to fix the catheter tip in or near the axial region of the coronary vein. He-Ne laser light (wave length = 632.8nm) is introduced into the blood through the optical fiber, and reflected light is collected by the same fiber. The Doppler signal is detected by a spectrum analyzer. To avoid any effect by the spikes on flow, the fiber is extended from the catheter tip by 3 mm at the time of measurement. Straight and curved tubing was used to examine the accuracy of flow measurement. The flow velocities recorded by the catheter, which were measured by an electromagnetic flowmeter, exhibited excellent linearity (r = straight; 0.982, curved: 0.996). The blood flow velocity in the great cardiac vein was measured by this method in five dogs. The predominantly systolic waveform, which is a characteristic of the coronary vein flow, was observed in all of the dogs. The great cardiac vein velocity increased around the beginning of the ventricular ejection and decreased gradually after the peak formation at mid- or end-diastole. In addition to this main peak, small flow components were frequently observed during isovolumic contraction and the atrial contraction phase, although these flow components varied in individual dogs. Following left anterior descending artery occlusion, the great cardiac vein flow velocity decreased significantly.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2149723     DOI: 10.1007/bf02301875

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  23 in total

1.  Optical-fiber laser Doppler velocimeter for high-resolution measurement of pulsatile blood flows.

Authors:  H Nishihara; J Koyama; N Hoki; F Kajiya; M Hironaga; M Kano
Journal:  Appl Opt       Date:  1982-05-15       Impact factor: 1.980

2.  In vivo evaluation of microcirculation by coherent light scattering.

Authors:  M D Stern
Journal:  Nature       Date:  1975-03-06       Impact factor: 49.962

3.  Measurement of the Velocity of Blood Flow (in vivo) Using a Fiber Optic Catheter and Optical Mixing Spectroscopy.

Authors:  T Tanaka; G B Benedek
Journal:  Appl Opt       Date:  1975-01-01       Impact factor: 1.980

4.  Pulsatile aspects of coronary sinus blood flow in closed-chest dogs.

Authors:  P D Stein; H S Badeer; W H Schuette; J F Glaser
Journal:  Am Heart J       Date:  1969-09       Impact factor: 4.749

5.  Continuous measurement of tissue blood flow by laser-Doppler spectroscopy.

Authors:  M D Stern; D L Lappe; P D Bowen; J E Chimosky; G A Holloway; H R Keiser; R L Bowman
Journal:  Am J Physiol       Date:  1977-04

6.  Dual-fiber laser Doppler velocimeter and its application to the measurements of coronary blood velocity.

Authors:  F Kajiya; O Hiramatsu; Y Ogasawara; K Mito; K Tsujioka
Journal:  Biorheology       Date:  1988       Impact factor: 1.875

7.  a new fiber-optic liquid crystal catheter for oxygen saturation and blood flow measurements in the coronary sinus.

Authors:  D De Rossi; A Benassi; A L'Abbate; P Dario
Journal:  J Biomed Eng       Date:  1980-10

8.  Antithrombogenic elastomers: novel anticoagulant/complement inhibitor-controlled release systems.

Authors:  T Matsuda; H Iwata; H Noda; T Toyosaki; H Takano; T Akutsu
Journal:  Trans Am Soc Artif Intern Organs       Date:  1985

9.  A Laser-Doppler-Velocimeter using an optical fiber and its application to local velocity measurement in the coronary artery.

Authors:  F Kajiya; N Hoki; G Tomonaga; H Nishihara
Journal:  Experientia       Date:  1981-11-15

10.  Evaluation of human coronary blood flow with an 80 channel 20 MHz pulsed Doppler velocimeter and zero-cross and Fourier transform methods during cardiac surgery.

Authors:  F Kajiya; Y Ogasawara; K Tsujioka; M Nakai; M Goto; Y Wada; S Tadaoka; S Matsuoka; K Mito; T Fujiwara
Journal:  Circulation       Date:  1986-11       Impact factor: 29.690

View more
  1 in total

1.  Noninvasive visualization and measurement of middle cardiac vein flow by transthoracic Doppler echocardiography.

Authors:  Kenji Harada; Masamichi Tamura; Manatoma Toyono
Journal:  Pediatr Cardiol       Date:  2006-10-09       Impact factor: 1.655