Literature DB >> 21497123

On impulse response functions computed from dynamic contrast-enhanced image data by algebraic deconvolution and compartmental modeling.

Gunnar Brix1, Mona Salehi Ravesh, Stefan Zwick, Jürgen Griebel, Stefan Delorme.   

Abstract

Concentration-time courses measured by dynamic contrast-enhanced (DCE) imaging can be described by a convolution of the arterial input with an impulse response function, Q(T)(t), characterizing tissue microcirculation. Data analysis is based on two different approaches: computation of Q(T)(t) by algebraic deconvolution (AD) and subsequent evaluation according to the indicator dilution theory (IDT) or parameterization of Q(T)(t) by analytical expressions derived by compartmental modeling. Pitfalls of both strategies will be addressed in this study. Tissue data acquired by DCE-CT in patients with head-and-neck cancer and simulated by a reference model (MMID4) were analyzed by a two-compartment model (TCM), a permeability-limited two-compartment model (PL-TCM) and AD. Additionally, MMID4 was used to compute the 'true' response function that corresponds to the simulated tumor data. TCM and AD yielded accurate fits, whereas PL-TCM performed worse. Nevertheless, the corresponding response functions diverge markedly. The response curves obtained by TCM decrease exponentially in the early perfusion phase and overestimate the tissue perfusion, Q(T)(0). AD also resulted in response curves starting with a negative slope and not - as the 'true' response function in accordance with the IDT - with a horizontal plateau. They are thus not valid responses in the sense of the IDT that can be used unconditionally for parameter estimation. Response functions differing considerably in shape can result in virtually identical tissue curves. This non-uniqueness makes a strong argument not to use algebraic but rather analytical deconvolution to reduce the class of solutions to representatives that are in accordance with a-priori knowledge. To avoid misinterpretations and systematic errors, users must be aware of the pitfalls inherent to the different concepts. Copyright Â
© 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21497123     DOI: 10.1016/j.ejmp.2011.03.004

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  5 in total

1.  Simulation study of the effect of golden-angle KWIC with generalized kinetic model analysis on diagnostic accuracy for lesion discrimination.

Authors:  Melanie Freed; Sungheon G Kim
Journal:  Magn Reson Imaging       Date:  2014-09-28       Impact factor: 2.546

2.  [Dynamic contrast-enhanced computed tomography. Tracer kinetics and radiation hygienic principles].

Authors:  G Brix; J Griebel; S Delorme
Journal:  Radiologe       Date:  2012-03       Impact factor: 0.635

3.  Direct characterization of arterial input functions by fluorescence imaging of exposed carotid artery to facilitate kinetic analysis.

Authors:  Jonathan T Elliott; Kenneth M Tichauer; Kimberley S Samkoe; Jason R Gunn; Kristian J Sexton; Brian W Pogue
Journal:  Mol Imaging Biol       Date:  2014-08       Impact factor: 3.488

4.  Measurement of blood-brain barrier permeability with t1-weighted dynamic contrast-enhanced MRI in brain tumors: a comparative study with two different algorithms.

Authors:  Maurizio Bergamino; Laura Saitta; Laura Barletta; Laura Bonzano; Giovanni Luigi Mancardi; Lucio Castellan; Jean Louis Ravetti; Luca Roccatagliata
Journal:  ISRN Neurosci       Date:  2013-02-20

5.  Assessing Treatment Response Through Generalized Pharmacokinetic Modeling of DCE-MRI Data.

Authors:  Eleftherios Kontopodis; Georgia Kanli; Georgios C Manikis; Sofie Van Cauter; Kostas Marias
Journal:  Cancer Inform       Date:  2015-08-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.