Literature DB >> 21496823

Fluid-structure interaction of deformable aortic prostheses with a bileaflet mechanical valve.

M D de Tullio1, L Afferrante, G Demelio, G Pascazio, R Verzicco.   

Abstract

Two different aortic prostheses can be used for performing the Bentall procedure: a standard straight graft and the Valsalva graft that better reproduces the aortic root anatomy. The aim of the present work is to study the effect of the graft geometry on the blood flow when a bileaflet mechanical heart valve is used, as well as to evaluate the stress concentration near the suture line where the coronary arteries are connected to graft. An accurate three-dimensional numerical method is proposed, based on the immersed boundary technique. The method accounts for the interactions between the flow and the motion of the rigid leaflets and of the deformable aortic root, under physiological pulsatile conditions. The results show that the graft geometry only slightly influences the leaflets dynamics, while using the Valsalva graft the stress level near the coronary-root anastomoses is about half that obtained using the standard straight graft.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Mesh:

Substances:

Year:  2011        PMID: 21496823     DOI: 10.1016/j.jbiomech.2011.03.036

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Derivation of a simplified relation for assessing aortic root pressure drop incorporating wall compliance.

Authors:  Hossein Mohammadi; Raymond Cartier; Rosaire Mongrain
Journal:  Med Biol Eng Comput       Date:  2014-11-28       Impact factor: 2.602

Review 2.  Review of numerical methods for simulation of mechanical heart valves and the potential for blood clotting.

Authors:  Mohamad Shukri Zakaria; Farzad Ismail; Masaaki Tamagawa; Ahmad Fazli Abdul Aziz; Surjatin Wiriadidjaja; Adi Azrif Basri; Kamarul Arifin Ahmad
Journal:  Med Biol Eng Comput       Date:  2017-07-26       Impact factor: 2.602

3.  The impact of the aortic valve impairment on the distant coronary arteries hemodynamics: a fluid-structure interaction study.

Authors:  Hossein Mohammadi; Raymond Cartier; Rosaire Mongrain
Journal:  Med Biol Eng Comput       Date:  2017-03-18       Impact factor: 2.602

4.  Annular dilatation and loss of sino-tubular junction in aneurysmatic aorta: implications on leaflet quality at the time of surgery. A finite element study.

Authors:  Luca Weltert; Marco D de Tullio; Luciano Afferrante; Andrea Salica; Raffaele Scaffa; Daniele Maselli; Roberto Verzicco; Ruggero De Paulis
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-03-27

5.  Effects of pannus formation on the flow around a bileaflet mechanical heart valve.

Authors:  Woojin Kim; Haecheon Choi; Jihoon Kweon; Dong Hyun Yang; Young-Hak Kim
Journal:  PLoS One       Date:  2020-06-12       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.