Literature DB >> 21495791

Cone beam CT verification for oesophageal cancer - impact of volume selected for image registration.

Maria A Hawkins1, Alexandra Aitken, Vibeke N Hansen, Helen A McNair, Diana M Tait.   

Abstract

PURPOSE: Oesophageal cancers are difficult to visualise on volumetric imaging and reliable surrogate are needed for accurate tumour registration. The aim of this investigation is to evaluate the effect of a user defined volume with automated registration techniques using commercially available software with the on-board volumetric imaging for treatment verification of oesophageal cancer and determine the optimum location of this volume.
MATERIAL AND METHODS: In 20 patients four 'clipbox'(C) volumes were defined: C-planning target volume (PTV), C-carina, C-vertebrae, C-thorax. The set-up corrections (translational and rotational) for C-PTV were compared to the corrections using C-carina, C-vertebrae and C-thorax.
RESULTS: Six hundred and eight registrations were performed. The best concordance in set-up corrections was found in the superior/inferior direction between C-PTV and C-carina (76%). In the right/left and anterior/posterior direction, better agreement was found between C-PTV and C-thorax with 80% and 76% agreement, respectively. Automatic 'bone' registration using C-vertebrae failed in 28% of scans. The correlation ratio between C-PTV and C-carina (n = 4) for mid-oesophageal tumours was 0.88, 0.79, and 0.95 in the right/left, superior/inferior and anterior/posterior directions, respectively.
CONCLUSION: The defined volume for matching is important for oesophageal tumours. The alignment 'clipbox' and registration method selected can affect the displacements obtained. This may best be determined by tumour location and highlights the need to diversify protocols within one tumour treatment site. Further analysis is required to validate carina as a tumour surrogate for mid-oesophageal tumours.

Entities:  

Mesh:

Year:  2011        PMID: 21495791     DOI: 10.3109/0284186X.2011.572912

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  7 in total

1.  High FDG uptake areas on pre-radiotherapy PET/CT identify preferential sites of local relapse after chemoradiotherapy for locally advanced oesophageal cancer.

Authors:  Jérémie Calais; Bernard Dubray; Lamyaa Nkhali; Sebastien Thureau; Charles Lemarignier; Romain Modzelewski; Isabelle Gardin; Frederic Di Fiore; Pierre Michel; Pierre Vera
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-02-14       Impact factor: 9.236

2.  IMPACT OF THREE DIFFERENT MATCHING METHODS ON PATIENT SET-UP ERROR IN X-RAY VOLUMETRIC IMAGING FOR HEAD AND NECK CANCER.

Authors:  P Mohandass; D Khanna; B Nishaanth; C Saravanan; Narendra Bhalla; Abhishek Puri; Blessy Mohandass
Journal:  Rep Pract Oncol Radiother       Date:  2020-09-21

3.  Comparison of planning target volumes based on three-dimensional and four-dimensional CT imaging of thoracic esophageal cancer.

Authors:  Wei Wang; Jianbin Li; Yingjie Zhang; Qian Shao; Min Xu; Tingyong Fan; Jinzhi Wang
Journal:  Onco Targets Ther       Date:  2016-08-02       Impact factor: 4.147

4.  Comparison of carina-based versus bony anatomy-based registration for setup verification in esophageal cancer radiotherapy.

Authors:  Mélanie Machiels; Peng Jin; Christianne H van Gurp; Jeanin E van Hooft; Tanja Alderliesten; Maarten C C M Hulshof
Journal:  Radiat Oncol       Date:  2018-03-21       Impact factor: 3.481

5.  Study to Compare the Effect of Different Registration Methods on Patient Setup Uncertainties in Cone-beam Computed Tomography during Volumetric Modulated Arc Therapy for Breast Cancer Patients.

Authors:  P Mohandass; D Khanna; T Manoj Kumar; T Thiyagaraj; C Saravanan; Narendra Kumar Bhalla; Abhishek Puri
Journal:  J Med Phys       Date:  2018 Oct-Dec

6.  Comparison of the Gross Target Volumes Based on Diagnostic PET/CT for Primary Esophageal Cancer.

Authors:  Jingzhen Shi; Jianbin Li; Fengxiang Li; Yingjie Zhang; Yanluan Guo; Wei Wang; Jinzhi Wang
Journal:  Front Oncol       Date:  2021-02-25       Impact factor: 6.244

7.  Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion.

Authors:  Katrina Woodford; Vanessa Panettieri; Jeremy D Ruben; Sidney Davis; Trieumy Tran Le; Stephanie Miller; Sashendra Senthi
Journal:  Radiat Oncol       Date:  2021-11-14       Impact factor: 3.481

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.