| Literature DB >> 21494804 |
Christian Bollensdorff1, Oleg Lookin, Peter Kohl.
Abstract
This paper briefly recapitulates the Frank-Starling law of the heart, reviews approaches to establishing diastolic and systolic force-length behaviour in intact isolated cardiomyocytes, and introduces a dimensionless index called 'Frank-Starling Gain', calculated as the ratio of slopes of end-systolic and end-diastolic force-length relations. The benefits and limitations of this index are illustrated on the example of regional differences in Guinea pig intact ventricular cardiomyocyte mechanics. Potential applicability of the Frank-Starling Gain for the comparison of cell contractility changes upon stretch will be discussed in the context of intra- and inter-individual variability of cardiomyocyte properties.Entities:
Mesh:
Year: 2011 PMID: 21494804 PMCID: PMC3114067 DOI: 10.1007/s00424-011-0964-z
Source DB: PubMed Journal: Pflugers Arch ISSN: 0031-6768 Impact factor: 3.657
Fig. 1Diagram representing end-diastolic and end-systolic force–length relations (EDFLR and ESFLR, respectively) of a Guinea pig intact isolated ventricular cardiomyocyte, established using the carbon fibre (CF) technique. The EDFLR (dashed line, blue) is obtained by monitoring passive tension (force required to arrive at different pre-loads), while ESFLR (dotted line, red) is constructed by recording total force at the end of contractions, initiated from a range of different pre-loads (here covering a sarcomere length [SL] range from 1.85 to 2.05 μm). In Guinea pig, over the SL studied, ESFLR is independent of the mode of contraction (e.g. auxotonic, grey lines; work-loop, black; data from [23]). Within this linear range of the Frank–Starling (FS) response, the slopes of ESFLR and EDFLR can be divided to yield a dimensionless index of the pre-load-dependent change in contractility — the Frank–Starling Gain (FSG). FSG calculation is independent of whether or not absolute or normalised force data are used (see scales on the left), and any errors introduced during normalisation of force to sample cross-section are cancelled out
Fig. 2Representative experimental records of a set of auxotonic twitches of Guinea pig ventricular cardiomyocyte and extraction of ED/ESFLR using the CF technique. a Time series of cell shortening (pointing downwards) and consecutively applied increases in diastolic length (pointing upwards). Note that the piezo-motor command (2-μm step, indicated by dotted lines above respective curve segments) exceeds actual cell strain; the difference between externally applied command and cell strain represents diastolic CF bending, used to calculate passive (diastolic) force. b Cell force recordings plotted as a function of time (force pointing upwards), superimposed for different pre-loads (numbers correspond to those in panels a and c). c EDFLR and ESFLR (force plotted as a function of pre-load, expressed as percentage of EDL0) using data points illustrated in panel b
Overview of cell geometry data, obtained at slack length for cells isolated from different regions of Guinea pig ventricle
| Region | Cell slack length (end-to-end) [μm] | SL0 [μm] | Cell width [μm] |
|---|---|---|---|
| RVbase | 146.6 ± 3.3 (46)a | 1.89 ± 0.01 (20)b | 18.6 ± 0.7 (53)c |
| RVapex | 148.2 ± 4.3 (43)a | 1.89 ± 0.01 (15)b | 19.2 ± 0.7 (53)c |
| RV (all) | 147.4 ± 2.7 (89) d | 1.89 ± 0.01 (35) | 18.9 ± 0.5 (106)d |
| LVbase_epi | 136.1 ± 4.3 (27) | 1.88 ± 0.01 (20)e | 22.0 ± 0.9 (41)c |
| LVbase_endo | 129.5 ± 3.3 (42)a | 1.88 ± 0.01 (26)e | 22.5 ± 0.7 (53)c |
| LVapex_epi | 139.6 ± 4.8 (21) | 1.89 ± 0.01 (18)e | 21.7 ± 0.8 (28)c |
| LVapex_endo | 147.7 ± 4.4 (28)a | 1.86 ± 0.01 (19)b, e | 22.9 ± 0.9 (37)c |
| LV (all) | 137.1 ± 2.1 (118)d | 1.88 ± 0.00 (83) | 22.3 ± 0.4 (159)d |
Data shown as mean ± SEM, number of measurements in round brackets
Two-tailed unpaired t test, P < 0.05:
aSignificant difference between LVbase_endo and each of (RVbase; RVapex; LVapex_endo)
bSignificant difference between LVapex_endo and each of (RVbase; RVapex)
cSignificant difference between any of (LVbase_epi; LVbase_endo; LVapex_epi, LVapex_endo) and each of (RVbase; RVapex)
dSignificant difference between pooled LV (all) and RV (all)
eSignificant difference between LVapex_endo and each of (LVbase_epi; LVbase_endo; LVapex_epi)
Slopes of ESFLR and EDFLR, and value of FSG index, for each tissue region studied
| Region | ESFLR slope [mN/mm2]/[ESL/EDL0] | EDFLR slope [mN/mm2]/[EDL/EDL0] | FSG [dimensionless] |
|---|---|---|---|
| RVbase | 1.04 ± 0.21 (11) | 0.27 ± 0.06 (11) | 4.37 ± 0.53 (11)a |
| RVapex | 1.01 ± 0.13 (14)b | 0.35 ± 0.04 (14)c | 2.99 ± 0.31 (14)a |
| RV (all) | 1.02 ± 0.12 (25)d | 0.31 ± 0.04 (25) | 3.59 ± 0.32 (25)d |
| LVbase_epi | 0.72 ± 0.09 (15) | 0.28 ± 0.03 (15)c | 2.66 ± 0.19 (15)a |
| LVbase_endo | 0.80 ± 0.10 (17) | 0.28 ± 0.03 (17) | 2.85 ± 0.22 (17)a |
| LVapex_epi | 0.85 ± 0.12 (16) | 0.28 ± 0.03 (16)c | 3.08 ± 0.25 (16)a |
| LVapex_endo | 0.68 ± 0.10 (11)b | 0.21 ± 0.02 (11) | 3.35 ± 0.36 (11) |
| LV (all) | 0.79 ± 0.05 (59)d | 0.26 ± 0.01 (59) | 3.04 ± 0.13 (59)d |
Data shown as mean ± SEM, number of measurements in round brackets
Unpaired t test, P < 0.05
aSignificant difference between RVbase and each of (RVapex; LVbase_epi; LVbase_endo; LVapex_epi)
bSignificant difference between RVapex and LVapex_endo
cSignificant difference between LVapex_endo and each of (RVapex, LVbase_epi; LVapex_epi)
dSignificant difference between pooled RV (all) and LV (all)
Fig. 3Illustration of differences in pre-load recruitable contractile reserve in cells with similar ESFLR, identified by FSG. Cells from RVbase and RVapex yield similar ESFLR (a) and EDFLR (b) slopes (individual data points and best linear fit shown). The non-significant trends toward higher ESFLR and lower EDFLR slopes in RVbase combine in a significantly increased FSG (*p < 0.05), which is indicative of a higher contractile reserve compared to RVapex. End-systolic force is expressed as percentage of ESF0 and end-systolic length as percentage of ESL0 (see Table 2 for details)