| Literature DB >> 21494389 |
Ahmet Atila Ertan1, Nilufer Celebi Beriat, Mehmet Ali Onur, Gamze Tan, Murat Cavit Cehreli.
Abstract
OBJECTIVES: The purpose of this study was to explore the effects dual-cure resin cements on nerve conduction.Entities:
Keywords: Light-emitting diode; Neurotoxicity; Quartz tungsten halogen; Rat; Resin cement; Sciatic nerve
Year: 2011 PMID: 21494389 PMCID: PMC3075997
Source DB: PubMed Journal: Eur J Dent
Resin cements used in the study.
| Panavia F | 10-Methacryloyloxydecyl dihydrogen phosphate | 41168 | Kuraray Dental INC. | Panavia |
| RelyX ARC | Fillers 60–70% | 20061204 | 3M, ESPE | RelyX |
| Variolink II | Paste of dimethacrylates, inorganic fillers, ytterbiumtrifluoride, initiators, stabilizers and pigments | J03326 | Ivoclar Vivadent | Variolink |
Descriptive statistics and percentage change of data acquired from sciatic nerves before (control) and after contact with resin cements during T1 and T2.
| Pan-LED | Mean±SD | 1.09±0.02 | 1.62±0.03 | 0.81±0.01 | 0.81±0.03 | 0.94(0.02) | 1.53±0.04 | 0.77±0.02 | 0.76±0.02 | 0.75±0.02 | 1.41±0.03 | 0.59±0.04 | 0.82±0.03 |
| Minimum | 1.05 | 1.59 | 0.78 | 0.75 | 0.90 | 1.44 | 0.73 | 0.70 | 0.72 | 1.35 | 0.53 | 0.77 | |
| Maximum | 1.12 | 1.69 | 0.83 | 0.87 | 0.97 | 1.58 | 0.82 | 0.79 | 0.78 | 1.47 | 0.67 | 0.87 | |
| % change | 100 | 100 | 100 | 100 | 85.95 | 94.27 | 95.27 | 93.46 | 68.91 | 87.16 | 72.71 | 101.72 | |
| Pan-QTH | Mean±SD | 0.37±0.01 | 0.73±0.01 | 0.36±0.01 | 0.36±0.01 | 0.37(0.01) | 0.73±0.01 | 0.37±0.01 | 0.36±0.01 | 0.32±0.01 | 0.70±0.00 | 0.35±0.01 | 0.34±0.00 |
| Minimum | 0.35 | 0.71 | 0.34 | 0.34 | 0.35 | 0.72 | 0.35 | 0.34 | 0.31 | 0.67 | 0.34 | 0.33 | |
| Maximum | 0.40 | 0.75 | 0.38 | 0.39 | 0.41 | 0.75 | 0.38 | 0.39 | 0.34 | 0.72 | 0.36 | 0.36 | |
| % change | 100 | 100 | 100 | 100 | 100.79 | 100.38 | 101.86 | 99.35 | 87.14 | 95.11 | 97.72 | 94.28 | |
| RelyX-LED | Mean±SD | 0.08±0.03 | 1.32±0.03 | 0.59±0.01 | 0.72±0.02 | 0.13(0.00) | 1.35±0.02 | 0.60±0.01 | 0.74±0.01 | 0.20±0.00 | 1.27±0.03 | 0.54±0.01 | 0.73±0.03 |
| Minimum | 0.03 | 1.26 | 0.57 | 0.68 | 0.13 | 1.31 | 0.58 | 0.71 | 0.20 | 1.20 | 0.50 | 0.68 | |
| Maximum | 0.12 | 1.35 | 0.61 | 0.75 | 0.13 | 1.37 | 0.61 | 0.76 | 0.21 | 1.35 | 0.57 | 0.79 | |
| % change | 100 | 100 | 100 | 100 | 197.62 | 102.28 | 101.85 | 102.69 | 305.19 | 96.60 | 91.85 | 100.34 | |
| RelyX-QTH | Mean±SD | 0.001±0.03 | 1.41±0.05 | 0.62±0.03 | 0.79±0.03 | −0.05(0.0) | 1.41±0.01 | 0.66±0.02 | 0.75±0.0 | −0.05±0.0 | 1.51±0.02 | 0.72±0.02 | 0.79±0.02 |
| Minimum | −0.05 | 1.34 | 0.57 | 0.75 | −0.06 | 1.39 | 0.62 | 0.73 | −0.10 | 1.47 | 0.69 | 0.75 | |
| Maximum | 0.04 | 1.50 | 0.68 | 0.83 | −0.05 | 1.45 | 0.69 | 0.76 | −0.03 | 1.56 | 0.75 | 0.83 | |
| % change | 100 | 100 | 100 | 100 | 48.31 | 100.09 | 105.33 | 95.94 | 61.53 | 107.22 | 115.28 | 100.74 | |
| Vario-LED | Mean±SD | 0.04±0.00 | 2.16±0.07 | 1.05±0.04 | 1.11±0.04 | 0.04(0.00) | 2.05±0.04 | 0.98±0.02 | 1.06±0.03 | 0.05±0.00 | 2.05±0.05 | 0.95±0.02 | 1.09±0.05 |
| Minimum | 0.02 | 2.05 | 0.98 | 1.03 | 0.04 | 1.98 | 0.92 | 1.00 | 0.05 | 1.99 | 0.91 | 1.03 | |
| Maximum | 0.04 | 2.25 | 1.11 | 1.15 | 0.04 | 2.14 | 1.02 | 1.12 | 0.05 | 2.15 | 0.99 | 1.21 | |
| % change | 100 | 100 | 100 | 100 | 96.11 | 95.17 | 93.74 | 96.14 | 130.43 | 94.95 | 90.76 | 98.57 | |
| Vario-QTH | Mean±SD | 2.98±0.04 | 1.57±0.01 | 1.07±0.01 | 0.49±0.01 | 3.00(0.03) | 1.57±0.01 | 1.07±0.01 | 0.49±0.02 | 2.68±0.02 | 1.57±0.01 | 1.26±0.01 | 0.30±0.02 |
| Maximum | 3.04 | 1.59 | 1.09 | 0.52 | 3.07 | 1.61 | 1.09 | 0.56 | 2.75 | 1.59 | 1.29 | 0.35 | |
| % change | 100 | 100 | 100 | 100 | 100.96 | 100.17 | 99.97 | 100.63 | 89.99 | 100.20 | 118.18 | 61.43 | |
T1: Data acquired during 0–10 minutes; T2: Data acquired during 50–60 minutes; Pan-LED: Panavia F polymerized by LED; Pan-QTH: Panavia F polymerized by QTH; RelyXLED: RelyX ARC polymerized by LED; RelyX-QTH: RelyX ARC polymerized by QTH; Vario-LED: Variolink II polymerized by LED; Vario-QTH: Variolink II polymerized by QTH.
P values for within-group comparisons.
| Pan-LED | 0.005 | 0.005 | 0.005 | 0.005 | 0.005 | 0.007 | 0.005 | 0.005 | 0.005 | 0.007 | 0.508 | 0.005 |
| Pan-QTH | 0.878 | 0.005 | 0.005 | 0.859 | 0.005 | 0.005 | 0.359 | 0.285 | 0.007 | 0.799 | 0.007 | 0.022 |
| RelyX-LED | 0.005 | 0.005 | 0.005 | 0.007 | 0.037 | 0.007 | 0.037 | 0.005 | 0.005 | 0.011 | 0.799 | 0.109 |
| RelyX-QTH | 0.005 | 0.037 | 0.093 | 0.959 | 0.008 | 0.005 | 0.047 | 0.005 | 0.005 | 0.028 | 0.646 | 0.013 |
| Vario-LED | 0.139 | 0.005 | 0.005 | 0.013 | 0.013 | 0.575 | 0.009 | 0.007 | 0.017 | 0.047 | 0.386 | 0.444 |
| Vario-QTH | 0.169 | 0.005 | 0.005 | 0.575 | 0.959 | 0.959 | 0.878 | 0.005 | 0.005 | 0.959 | 0.005 | 0.005 |
not significant; C:Control; T1: Data acquired during 0–10 minutes; T2: Data acquired during 50–60 minutes; Pan-LED: Panavia F polymerized by LED; Pan-QTH: Panavia F polymerized by QTH; RelyX-LED: RelyX ARC polymerized by LED; RelyX-QTH RelyX ARC polymerized by QTH; Vario-LED: Variolink II polymerized by LED; Vario-QTH: Variolink II polymerized by QTH.
P values for between-group comparisons.
| LED | Pan-RelyX | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.631 |
| Pan-Vario | 0.00 | 0.912 | 0.247 | 0.218 | 0.00 | 0.00 | 0.00 | 0.28 | |
| RelyX-Vario | 0.00 | 0.001 | 0.001 | 0.007 | 0.00 | 0.436 | 0.579 | 0.529 | |
| QTH | Pan-RelyX | 0.00 | 0.94 | 0.226 | 0.406 | 0.028 | 0.00 | 0.00 | 0.023 |
| Pan-Vario | 0.88 | 0.762 | 0.226 | 0.545 | 0.049 | 0.001 | 0.00 | 0.00 | |
| RelyX-Vario | 0.00 | 0.762 | 0.131 | 0.112 | 0.023 | 0.004 | 0.226 | 0.00 | |
not significant; T1: Data acquired during 0–10 minutes; T2: Data acquired during 50–60 minutes; PAN: Panavia F; Vario: Variolink II