Literature DB >> 21494361

Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty.

Hyun-Chul Choi1.   

Abstract

OBJECTIVE: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty.
METHODS: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups.
RESULTS: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee : 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds.
CONCLUSION: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

Entities:  

Keywords:  Dosimetry; Fluoroscopic guidance; Fluoroscopy; Kyphoplasty; Radiation exposure; Radiation safety

Year:  2011        PMID: 21494361      PMCID: PMC3070893          DOI: 10.3340/jkns.2011.49.1.37

Source DB:  PubMed          Journal:  J Korean Neurosurg Soc        ISSN: 1225-8245


  16 in total

1.  Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion.

Authors:  Y R Rampersaud; K T Foley; A C Shen; S Williams; M Solomito
Journal:  Spine (Phila Pa 1976)       Date:  2000-10-15       Impact factor: 3.468

2.  Radiation dose to the operator during vertebroplasty: prospective comparison of the use of 1-cc syringes versus an injection device.

Authors:  David F Kallmes; Erwin O; Soma Sinha Roy; Richard G Piccolo; William F Marx; Jae K Lee; Mary E Jensen
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

3.  Radiation dose reduction to medical staff during vertebroplasty: a review of techniques and methods to mitigate occupational dose.

Authors:  Randell Kruger; Thomas Faciszewski
Journal:  Spine (Phila Pa 1976)       Date:  2003-07-15       Impact factor: 3.468

4.  Vertebroplasty and kyphoplasty: do fluoroscopy operators know about radiation dose, and should they want to know?

Authors:  J Anthony Seibert
Journal:  Radiology       Date:  2004-09       Impact factor: 11.105

5.  Radiation dose in vertebroplasty.

Authors:  A Mehdizade; K O Lovblad; K E Wilhelm; T Somon; S G Wetzel; A D Kelekis; H Yilmaz; G Abdo; J B Martin; J M Viera; D A Rüfenacht
Journal:  Neuroradiology       Date:  2004-02-14       Impact factor: 2.804

6.  Surgeon's radiation exposure during percutaneous vertebroplasty.

Authors:  Michael Synowitz; Juergen Kiwit
Journal:  J Neurosurg Spine       Date:  2006-02

7.  Patient exposure and associated radiation risks from fluoroscopically guided vertebroplasty or kyphoplasty.

Authors:  Kostas Perisinakis; John Damilakis; Nicholas Theocharopoulos; George Papadokostakis; Alexandros Hadjipavlou; Nicholas Gourtsoyiannis
Journal:  Radiology       Date:  2004-07-23       Impact factor: 11.105

8.  Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery.

Authors:  Choll W Kim; Yu-Po Lee; William Taylor; Ahmet Oygar; Woo Kyung Kim
Journal:  Spine J       Date:  2007-02-20       Impact factor: 4.166

Review 9.  Medical interventional procedures-reducing the radiation risks.

Authors:  C Cousins; C Sharp
Journal:  Clin Radiol       Date:  2004-06       Impact factor: 2.350

10.  Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures.

Authors:  Koichi Chida; Haruo Saito; Hiroki Otani; Masahiro Kohzuki; Shoki Takahashi; Shogo Yamada; Kunio Shirato; Masayuki Zuguchi
Journal:  AJR Am J Roentgenol       Date:  2006-03       Impact factor: 3.959

View more
  6 in total

1.  Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose.

Authors:  S Harrison Farber; Gautam Nayar; Rupen Desai; Elizabeth W Reiser; Sarah A Byrd; Deborah Chi; Cary Idler; Robert E Isaacs
Journal:  Eur Spine J       Date:  2018-06-08       Impact factor: 3.134

2.  Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty.

Authors:  Joshua R Smith; Rebecca M Marsh; Michael S Silosky
Journal:  Skeletal Radiol       Date:  2017-08-18       Impact factor: 2.199

3.  Radiation dose to the operator during fluoroscopically guided spine procedures.

Authors:  Luca Roccatagliata; Stefano Presilla; Emanuele Pravatà; Alessandro Cianfoni
Journal:  Neuroradiology       Date:  2017-07-18       Impact factor: 2.804

4.  Radiation safety for pain physicians.

Authors:  Sang Wook Shin
Journal:  Korean J Pain       Date:  2012-04-04

Review 5.  Kyphoplasty in osteoporotic vertebral compression fractures--guidelines and technical considerations.

Authors:  Yohan Robinson; Christoph E Heyde; Peter Försth; Claes Olerud
Journal:  J Orthop Surg Res       Date:  2011-08-19       Impact factor: 2.359

6.  Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System: Preliminary Report of Prospective Hello Study.

Authors:  Guoxin Fan; Xiaofei Guan; Hailong Zhang; Xinbo Wu; Xin Gu; Guangfei Gu; Yunshan Fan; Shisheng He
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817