Literature DB >> 21492730

"Stent view" flat-detector CT and stent-assisted treatment strategies for complex intracranial aneurysms.

Michael R Levitt1, Daniel L Cooke, Basavaraj V Ghodke, Louis J Kim, Danial K Hallam, Laligam N Sekhar.   

Abstract

BACKGROUND: Complex intracranial aneurysms are often treated with endovascular stent-assisted coiling. Intracranial stents are difficult to visualize with conventional computed tomography (CT) or fluoroscopy. "Stent view" flat-detector CT can be used to visualize intracranial stents during endovascular treatment.
METHODS: Three patients underwent endovascular treatment of complex intracranial aneurysms. Stent view flat-detector CT was used to study stent placement and morphology in vivo.
RESULTS: Stent view CT was successful in visualizing stents in all patients. In two patients, stent morphology rendered endovascular coiling technically unfeasible; in one patient, visualization of stent strut herniation into the aneurysm lumen allowed successful coil embolization of the aneurysm.
CONCLUSIONS: Stent view CT provided detailed imaging of stent placement and morphology in all three cases. The technique influenced treatment decisions and technical outcomes. Stent view CT is a valuable intraprocedural technical tool in stent-assisted endovascular procedures.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21492730     DOI: 10.1016/j.wneu.2010.07.042

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  4 in total

1.  Platelet Dynamics and Hemodynamics of Cerebral Aneurysms Treated with Flow-Diverting Stents.

Authors:  Laurel M M Marsh; Michael C Barbour; Venkat Keshav Chivukula; Fanette Chassagne; Cory M Kelly; Samuel H Levy; Louis J Kim; Michael R Levitt; Alberto Aliseda
Journal:  Ann Biomed Eng       Date:  2019-09-23       Impact factor: 3.934

2.  Cerebral aneurysms treated with flow-diverting stents: computational models with intravascular blood flow measurements.

Authors:  M R Levitt; P M McGah; A Aliseda; P D Mourad; J D Nerva; S S Vaidya; R P Morton; B V Ghodke; L J Kim
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-18       Impact factor: 3.825

3.  Combination of high-resolution cone beam computed tomography and metal artefact reduction software: a new image fusion technique for evaluating intracranial stent apposition after aneurysm treatment.

Authors:  Ichiro Yuki; Toshihiro Ishibashi; Chihebeddine Dahmani; Naoki Kato; Ayako Ikemura; Yukiko Abe; Katharina Otani; Tomonobu Kodama; Issei Kan; Kengo Nishimura; Yuichi Murayama
Journal:  BMJ Case Rep       Date:  2019-09-17

Review 4.  Toward the era of a one-stop imaging service using an angiography suite for neurovascular disorders.

Authors:  Sheng-Che Hung; Chung-Jung Lin; Wan-Yuo Guo; Feng-Chi Chang; Chao-Bao Luo; Michael Mu-Huo Teng; Cheng-Yen Chang
Journal:  Biomed Res Int       Date:  2013-05-14       Impact factor: 3.411

  4 in total