Literature DB >> 21488966

Registration accuracy of three-dimensional surface and cone beam computed tomography data for virtual implant planning.

L Ritter1, S D Reiz, D Rothamel, T Dreiseidler, V Karapetian, M Scheer, J E Zöller.   

Abstract

OBJECTIVE: Virtual wax-ups based on three-dimensional (3D) surface models can be matched (i.e. registered) to cone beam computed tomography (CBCT) data of the same patient for dental implant planning. Thereby, implant planning software can visualize anatomical and prosthetic information simultaneously. The aim of this study is to assess the accuracy of a newly developed registration process.
MATERIAL AND METHODS: Data pairs of CBCT and 3D surface data of 16 patients for dental implant planning were registered and the discrepancy between the visualized 3D surface data and the corresponding CBCT data were measured on 64 teeth at seven points by two investigators in two iterations with a total of 1792 measurements.
RESULTS: All data pairs were matched successfully and mean distances between CBCT and 3D surface data were between 0.03(±0.33) and 0.14(±0.18) mm. At two of seven measuring points, statistically significant correlations were determined between the measured error and the presence and type of restorations. Registration errors in maxilla and mandible were not statistically significantly different.
CONCLUSION: According to the results of this study, registration of 3D surface data and CBCT data works reliably and is sufficiently accurate for dental implant planning. Thereby, barium-sulfate scanning templates can be avoided and dental implant planning can be accomplished fully virtual.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2011        PMID: 21488966     DOI: 10.1111/j.1600-0501.2011.02159.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

1.  [Criteria for success in dental implants].

Authors:  Yi Man; Hai-Yang Yu; Zuo-Lin Wang; Yao Wu; Bang-Cheng Yang; Lei Cheng; Xue-Dong Zhou; Yao Sun
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2019-02-01

2.  Digital implant planning and guided implant surgery - workflow and reliability.

Authors:  O Schubert; J Schweiger; M Stimmelmayr; E Nold; J-F Güth
Journal:  Br Dent J       Date:  2019-01-25       Impact factor: 1.626

3.  Fully customized placement of orthodontic miniplates: a novel clinical technique.

Authors:  Jan Hourfar; Georgios Kanavakis; Peter Goellner; Björn Ludwig
Journal:  Head Face Med       Date:  2014-05-03       Impact factor: 2.151

Review 4.  Cone beam computed tomography in implant dentistry: recommendations for clinical use.

Authors:  Reinhilde Jacobs; Benjamin Salmon; Marina Codari; Bassam Hassan; Michael M Bornstein
Journal:  BMC Oral Health       Date:  2018-05-15       Impact factor: 2.757

5.  Impact of Matching Point Selections on Image Registration Accuracy between Optical Scan and Computed Tomography.

Authors:  Hai Yen Mai; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2020-08-04       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.