Literature DB >> 21484733

Functional and radiological evaluation of a simple intra operative technique to avoid limb length discrepancy in total hip arthroplasty.

Aravind S Desai1, Liz Connors, Timothy N Board.   

Abstract

We aimed to assess the radiological and functional outcome of total hip arthroplasty performed using a simple technique for intra-operative leg length assessment. The comparative group was made up of patients receiving total hip arthroplasty prior to introduction of the technique. Fifty patients were studied in each group. The pre- and 3 month post-operative leg length difference (LLD) was measured radiologically along with pre- and 12 months post-operative Oxford hip scores (OHS) and University of California Los Angeles (UCLA) activity scores.There were no statistically significant differences in pre-operative parameters between the two groups. The mean LLD in the new technique group was 0.46 mm which was significantly less than in the control group (p< 0.001). Post operative OHS values were worse when shortening or lengthening was >5 mm in both groups. UCLA activity scores were significantly better in the new technique group than in the control group (p< 0.001). The overall radiological and functional outcome of the patients was better in the new technique group.Functional outcome is related to small differences in leg length and our simple new technique can be used to control leg length intraoperatively.

Entities:  

Mesh:

Year:  2011        PMID: 21484733     DOI: 10.5301/HIP.2011.6514

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  4 in total

1.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

2.  Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty.

Authors:  Xing Chen; Shuxing Xing; Zhiyong Zhu; Huisheng Wang; Zhongshen Yu; Xizhuang Bai; Xi Li
Journal:  Front Surg       Date:  2022-03-03

3.  Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture.

Authors:  Zhanle Zheng; Lei Yang; Yanling Su; Xian Yu; Zhiyong Hou; Yingze Zhang
Journal:  BMC Surg       Date:  2017-05-15       Impact factor: 2.102

Review 4.  What is the optimal time point to assess patient-reported recovery after hip and knee replacement? A systematic review and analysis of routinely reported outcome data from the English patient-reported outcome measures programme.

Authors:  John Patrick Browne; Hamad Bastaki; Jill Dawson
Journal:  Health Qual Life Outcomes       Date:  2013-07-30       Impact factor: 3.186

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.