Literature DB >> 21482869

Comparison of ocular response analyzer parameters in chinese subjects with primary angle-closure and primary open-angle glaucoma.

Arun Narayanaswamy1, Daniel H Su, Mani Baskaran, Anna C S Tan, Monisha E Nongpiur, Hla M Htoon, Tien Y Wong, Tin Aung.   

Abstract

OBJECTIVES: To evaluate corneal hysteresis (CH) and intraocular pressure (IOP) measured by the Ocular Response Analyzer in Chinese subjects with primary angle-closure glaucoma (PACG), assess their relationship with Goldmann applanation tonometry (GAT) measurements, and compare this with subjects with primary open-angle glaucoma (POAG) and normal controls.
METHODS: In this prospective observational study, consecutive subjects with PACG and POAG without prior intraocular surgery were enrolled from glaucoma clinics. Normal subjects were recruited from an ongoing population-based study. One eye of each subject underwent standardized ocular examination and IOP measurement by GAT and the Ocular Response Analyzer. Corneal hysteresis and corneal-compensated IOP were compared between groups.
RESULTS: Of the 443 subjects recruited, 131 had PACG, 162 had POAG, and 150 were normal. Corneal hysteresis was lower in PACG (9.1 mm Hg; 95% confidence interval [CI], 8.7 to 9.4 mm Hg) and POAG (9.5 mm Hg; 95% CI, 9.2 to 9.5 mm Hg) eyes compared with control eyes (10.4 mm Hg; 95% CI, 10.1 to 10.6 mm Hg; P < .001 for both), with no difference (P = .16) in CH found between PACG and POAG eyes. After adjusting for age, sex, and IOP measurement by GAT, CH persisted to be lower only in eyes with PACG in comparison with control eyes (9.4 vs 10.1 mm Hg; P = .006). Eyes with POAG had lower CH than control eyes but the difference was not statistically significant (9.6 vs 10.1 mm Hg; P = .06).
CONCLUSIONS: Corneal hysteresis was lower in eyes with glaucoma. After adjusting for age, sex, and IOP measurement by GAT, a persistently lower hysteresis was noted in eyes with PACG compared with other groups.

Entities:  

Mesh:

Year:  2011        PMID: 21482869     DOI: 10.1001/archophthalmol.2011.60

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  13 in total

1.  Corneal biomechanical changes after trabeculectomy with mitomycin C in primary open-angle glaucoma and pseudoexfoliation glaucoma.

Authors:  Rana Sorkhabi; Farhad Najafzadeh; Ali Sadeghi; Mohamadhosein Ahoor; Ali Mahdavifard
Journal:  Int Ophthalmol       Date:  2019-05-27       Impact factor: 2.031

2.  Corneal hysteresis and anterior segment optical coherence tomography anatomical parameters in primary angle closure suspects.

Authors:  Syed Amal Hussnain; Kyle D Kovacs; Joshua L Warren; Christopher C Teng
Journal:  Clin Exp Ophthalmol       Date:  2018-01-11       Impact factor: 4.207

3.  Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment.

Authors:  D Pensyl; M Sullivan-Mee; M Torres-Monte; K Halverson; C Qualls
Journal:  Eye (Lond)       Date:  2012-08-10       Impact factor: 3.775

Review 4.  The importance of assessing corneal biomechanical properties in glaucoma patients care - a review.

Authors:  Dana Dascalescu; Catalina Corbu; Potop Vasile; Raluca Iancu; Miruna Cristea; Catalina Ionescu; Ciuluvica Radu Constantin; Liliana Voinea
Journal:  Rom J Ophthalmol       Date:  2016 Oct-Dec

Review 5.  Corneal hysteresis and its relevance to glaucoma.

Authors:  Madhvi Deol; David A Taylor; Nathan M Radcliffe
Journal:  Curr Opin Ophthalmol       Date:  2015-03       Impact factor: 3.761

6.  The effect of air pulse-driven whole eye motion on the association between corneal hysteresis and glaucomatous visual field progression.

Authors:  Shuichiro Aoki; Hiroshi Murata; Masato Matsuura; Yuri Fujino; Shunsuke Nakakura; Yoshitaka Nakao; Yoshiaki Kiuchi; Ryo Asaoka
Journal:  Sci Rep       Date:  2018-02-14       Impact factor: 4.379

7.  Rate of central corneal thickness changes in primary angle closure eyes: long-term follow-up results.

Authors:  Hae Min Park; Jiin Choi; Won June Lee; Ki Bang Uhm
Journal:  BMC Ophthalmol       Date:  2021-03-22       Impact factor: 2.209

8.  The role of corneal hysteresis during the evaluation of patients with possible normal-tension glaucoma.

Authors:  Ming Chen; Laura Kueny; Arthur L Schwartz
Journal:  Clin Ophthalmol       Date:  2018-03-21

9.  Correlation between elastic energy stored in an eye and visual field progression in glaucoma.

Authors:  Shuichiro Aoki; Hiroshi Murata; Shunsuke Nakakura; Yoshitaka Nakao; Masato Matsuura; Yoshiaki Kiuchi; Ryo Asaoka
Journal:  PLoS One       Date:  2018-09-21       Impact factor: 3.240

10.  In vivo assessment of changes in corneal hysteresis and lamina cribrosa position during acute intraocular pressure elevation in eyes with markedly asymmetrical glaucoma.

Authors:  Corrado Gizzi; Mauro Cellini; Emilio C Campos
Journal:  Clin Ophthalmol       Date:  2018-03-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.