Literature DB >> 21476036

Does drainage hole size influence adhesion on ventricular catheters?

Carolyn A Harris1, James P McAllister.   

Abstract

PURPOSE: Ventricular catheter drainage holes of shunt systems used to treat hydrocephalus obstruct with tissue commonly comprising monocytes/macrophages, astrocytes, and giant cells. Despite high rates of obstruction, very few studies have manipulated drainage hole orientation, number, position, or diameter. By altering the hole diameter but maintaining a constant hole surface area, we manipulated shear stress through the holes, which we hypothesized would change the degree of macrophage and astrocyte attachment.
METHODS: First, a hole fabrication method was chosen from two fabrication techniques including punched holes in catheter tubing and constructed holes using nanofabrication techniques.
RESULTS: Punched holes were chosen to vary hole size from 282 to 975 μm because (1) samples were geometrically similar to commercially available ventricular catheters without significant microscopic differences in roughness values and (2) total macrophage and astrocyte adhesion on the punched holes was not significantly different from adhesion on the commercially available catheters. Overall adhesion from least to most adherent appeared to follow 975 < 754 ≈ 500 < 282-μm hole diameter for macrophages and 975 < 500 < 754 < 282 for astrocytes with an obvious dependency on catheter orientation with respect to the horizontal; a dependency to the proximity of the hole to the catheter tip was not observed.
CONCLUSION: This study suggests that macrophage and astrocyte adhesion generally decreases with increasing hole diameter under flow conditions and underscores the necessity for future work to examine how hole diameter impacts inflammatory-based shunt obstruction.

Entities:  

Mesh:

Year:  2011        PMID: 21476036     DOI: 10.1007/s00381-011-1430-0

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  19 in total

Review 1.  Kinetics of receptor-ligand interactions in immune responses.

Authors:  Mian Long; Shouqin Lü; Ganyun Sun
Journal:  Cell Mol Immunol       Date:  2006-04       Impact factor: 11.530

2.  Recanalization of obstructed cerebrospinal fluid ventricular catheters using ultrasonic cavitation.

Authors:  Howard J Ginsberg; James M Drake; Thomas M Peterson; Richard S C Cobbold
Journal:  Neurosurgery       Date:  2006-10       Impact factor: 4.654

3.  Microfabrication of cavities in polydimethylsiloxane using DRIE silicon molds.

Authors:  Ut-Binh T Giang; Dooyoung Lee; Michael R King; Lisa A DeLouise
Journal:  Lab Chip       Date:  2007-10-12       Impact factor: 6.799

Review 4.  Mechanisms for flow-enhanced cell adhesion.

Authors:  Cheng Zhu; Tadayuki Yago; Jizhong Lou; Veronika I Zarnitsyna; Rodger P McEver
Journal:  Ann Biomed Eng       Date:  2008-02-26       Impact factor: 3.934

5.  Effects of surface wettability, flow, and protein concentration on macrophage and astrocyte adhesion in an in vitro model of central nervous system catheter obstruction.

Authors:  Carolyn A Harris; James H Resau; Eric A Hudson; Richard A West; Candice Moon; Andrew D Black; James P McAllister
Journal:  J Biomed Mater Res A       Date:  2011-04-11       Impact factor: 4.396

6.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

7.  Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems.

Authors:  Alvaro Mata; Aaron J Fleischman; Shuvo Roy
Journal:  Biomed Microdevices       Date:  2005-12       Impact factor: 2.838

8.  The cytopathology of reactions to ventricular shunts.

Authors:  S H Bigner; P D Elmore; A L Dee; W W Johnston
Journal:  Acta Cytol       Date:  1985 May-Jun       Impact factor: 2.319

9.  Reaction of rabbit lateral periventricular tissue to shunt tubing implants.

Authors:  M R Del Bigio; J E Bruni
Journal:  J Neurosurg       Date:  1986-06       Impact factor: 5.115

10.  Microtopography and soft tissue response.

Authors:  C E Campbell; A F von Recum
Journal:  J Invest Surg       Date:  1989       Impact factor: 2.533

View more
  20 in total

1.  Computational fluid dynamics of ventricular catheters used for the treatment of hydrocephalus: a 3D analysis.

Authors:  Marcelo Galarza; Ángel Giménez; José Valero; Olga Porcar Pellicer; José María Amigó
Journal:  Childs Nerv Syst       Date:  2013-07-24       Impact factor: 1.475

2.  Basic cerebrospinal fluid flow patterns in ventricular catheters prototypes.

Authors:  Marcelo Galarza; Ángel Giménez; José Valero; Olga Pellicer; Juan F Martínez-Lage; José M Amigó
Journal:  Childs Nerv Syst       Date:  2015-02-17       Impact factor: 1.475

3.  Enhanced wall shear stress prevents obstruction by astrocytes in ventricular catheters.

Authors:  S Lee; N Kwok; J Holsapple; T Heldt; L Bourouiba
Journal:  J R Soc Interface       Date:  2020-07-01       Impact factor: 4.118

Review 4.  Cerebrospinal Fluid Shunting Complications in Children.

Authors:  Brian W Hanak; Robert H Bonow; Carolyn A Harris; Samuel R Browd
Journal:  Pediatr Neurosurg       Date:  2017-03-02       Impact factor: 1.162

5.  Pulsatile flow in ventricular catheters for hydrocephalus.

Authors:  Á Giménez; M Galarza; U Thomale; M U Schuhmann; J Valero; J M Amigó
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2017-06-28       Impact factor: 4.226

6.  Reduced cell attachment to poly(2-hydroxyethyl methacrylate)-coated ventricular catheters in vitro.

Authors:  Brian W Hanak; Chia-Yun Hsieh; William Donaldson; Samuel R Browd; Kenneth K S Lau; William Shain
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-06-20       Impact factor: 3.368

7.  New designs of ventricular catheters for hydrocephalus by 3-D computational fluid dynamics.

Authors:  Marcelo Galarza; Ángel Giménez; Olga Pellicer; José Valero; José M Amigó
Journal:  Childs Nerv Syst       Date:  2014-08-06       Impact factor: 1.475

8.  Next generation of ventricular catheters for hydrocephalus based on parametric designs.

Authors:  M Galarza; A Giménez; J M Amigó; M Schuhmann; R Gazzeri; U Thomale; J P McAllister
Journal:  Childs Nerv Syst       Date:  2017-08-15       Impact factor: 1.475

9.  Computational Modeling and Simulation to Quantify the Effects of Obstructions on the Performance of Ventricular Catheters Used in Hydrocephalus Treatment.

Authors:  Stephanie TerMaath; Douglas Stefanski; James Killeffer
Journal:  Methods Mol Biol       Date:  2022

10.  High-resistance proximal "scaled" ventricular catheters.

Authors:  David Qi; Elsa Olson; Sven Ivankovic; Taylor Sommer; Kalyani Nair; Martin Morris; Julian Lin
Journal:  Childs Nerv Syst       Date:  2021-10-15       Impact factor: 1.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.