Literature DB >> 21474853

Aortic root and valve thrombosis after implantation of a left ventricular assist device.

Benjamin H Freed1, Valluvan Jeevanandam, Neeraj Jolly.   

Abstract

We describe the case of a 60-year-old female who presented with a non-ST elevation myocardial infarction 3 months following placement of a non-pulsatile left ventricular assist device (LVAD). Aortic root angiography not only revealed extensive aortic root thrombosis and left main thrombotic obstruction, but also vividly demonstrated the causative mechanism. To our knowledge, this rarely described mechanism of LVAD thrombosis has not been reported as clearly as this case illustrates.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21474853

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  7 in total

1.  Left coronary artery occlusion caused by a large thrombus on the left coronary cusp in a patient with a continuous-flow ventricular assist device.

Authors:  Seiko Nakajima; Osamu Seguchi; Yoshihiro Murata; Tomoyuki Fujita; Hiroki Hata; Takafumi Yamane; Michinari Hieda; Takuya Watanabe; Takuma Sato; Haruki Sunami; Masanobu Yanase; Junjiro Kobayashi; Takeshi Nakatani
Journal:  J Artif Organs       Date:  2014-02-08       Impact factor: 1.731

Review 2.  Medical Management of Pump-Related Thrombosis in Patients with Continuous-Flow Left Ventricular Assist Devices: A Systematic Review and Meta-Analysis.

Authors:  Geetanjali Dang; Narendranath Epperla; Vijayadershan Muppidi; Natasha Sahr; Amy Pan; Pippa Simpson; Lisa Baumann Kreuziger
Journal:  ASAIO J       Date:  2017 Jul/Aug       Impact factor: 2.872

3.  Aortic root thrombosis leading to STEMI in a Heartmate 3 patient.

Authors:  Onyedika J Ilonze; Asad Torabi; Maya Guglin; Kashif Saleem; Roopa Rao
Journal:  J Artif Organs       Date:  2022-05-23       Impact factor: 1.731

4.  Computational fluid dynamic analysis to prevent aortic root and valve clots during left ventricular assist device support.

Authors:  Michael Poullis
Journal:  J Extra Corpor Technol       Date:  2012-12

Review 5.  Why pulsatility still matters: a review of current knowledge.

Authors:  Davor Barić
Journal:  Croat Med J       Date:  2014-12       Impact factor: 1.351

Review 6.  Continuous-Flow Left Ventricular Assist Device Thrombosis: A Danger Foreseen is a Danger Avoided.

Authors:  Javid Fatullayev; Mostafa Samak; Anton Sabashnikov; Mohamed Zeriouh; Parwis B Rahmanian; Yeong-Hoon Choi; Bastian Schmack; Klaus Kallenbach; Arjang Ruhparwar; Kaveh Eghbalzadeh; Pascal M Dohmen; Matthias Karck; Jens Wippermann; Thorsten Wahlers; Aron-Frederik Popov; Andre R Simon; Alexander Weymann
Journal:  Med Sci Monit Basic Res       Date:  2015-07-01

Review 7.  Facilitating noncardiac surgery for the patient with left ventricular assist device: A guide for the anesthesiologist.

Authors:  Kai-Yin Hwang; Nian-Chih Hwang
Journal:  Ann Card Anaesth       Date:  2018 Oct-Dec
  7 in total