Literature DB >> 21472383

Experimental and finite element analysis of the mouse caudal vertebrae loading model: prediction of cortical and trabecular bone adaptation.

D Webster1, A Wirth, G H van Lenthe, R Müller.   

Abstract

In this study, we attempt to predict cortical and trabecular bone adaptation in the mouse caudal vertebrae loading model using knowledge of bone's local mechanical environment at the onset of loading. In a previous study, we demonstrated appreciable 25.9 and 11% increases in both trabecular and cortical bone volume density, respectively, when subjecting the fifth caudal vertebrae (C5) of C57BL/6 (B6) mice to an acute loading regime (amplitude of 8N, 3000 cycles, 10 Hz, 3 times a week for 4 weeks). We have also established a validated finite element (FE) model of the C5 vertebra using micro-computed tomography (micro-CT), which characterizes, in 3D, the micro-mechanical strains present in both cortical and trabecular compartments due to the applied loads. To investigate the relationship between load-induced bone adaptation and mechanical strains in-vivo and in-silico data sets were compared. Using data from the previous cross-sectional study, we divided cortical and trabecular compartments into 15 subregions and determined, for each region, a bone formation parameter ΔBV/BS (a cross-sectional measure of the bone volume added to cortical and trabecular surfaces following the described loading regime). Linear regression was then used to correlate mean regional values of ΔBV/BS with mean values of mechanical strains derived from the FE models which were similarly regionalized. The mechanical parameters investigated were strain energy density (SED), the orthogonal strains (e (x), e (y), e (z)) and the three shear strains (e (xy), e (yz), e (zx)). For cortical regions, regression analysis showed SED to correlate extremely well with ΔBV/BS (R (2) = 0.82) and e (z) (R (2) = 0.89). Furthermore, SED was found to predict expansion of the cortical shell correlating significantly with the regional percentage increases in cortical tissue volume (R (2) = 0.92), cortical marrow volume (R (2) = 0.91) and cortical thickness (R (2) = 0.56). For trabecular regions, FE parameters were found not to correlate with load-induced trabecular bone morphology. These results indicate that load-induced cortical morphology can be predicted from population data, whereas the prediction of trabecular morphology requires subject-specific micro- architecture.

Entities:  

Mesh:

Year:  2011        PMID: 21472383     DOI: 10.1007/s10237-011-0305-3

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  11 in total

1.  A computational model to describe the regional interlamellar shear of the annulus fibrosus.

Authors:  Kevin M Labus; Sang Kuy Han; Adam H Hsieh; Christian M Puttlitz
Journal:  J Biomech Eng       Date:  2014-05       Impact factor: 2.097

Review 2.  Studying osteocytes within their environment.

Authors:  Duncan J Webster; Philipp Schneider; Sarah L Dallas; Ralph Müller
Journal:  Bone       Date:  2013-01-11       Impact factor: 4.398

3.  A novel use of 3D printing model demonstrates the effects of deteriorated trabecular bone structure on bone stiffness and strength.

Authors:  Meir Max Barak; Margaret Arielle Black
Journal:  J Mech Behav Biomed Mater       Date:  2017-12-07

Review 4.  Multiscale finite element modeling of mechanical strains and fluid flow in osteocyte lacunocanalicular system.

Authors:  Thiagarajan Ganesh; Loretta E Laughrey; Mohammadmehdi Niroobakhsh; Nuria Lara-Castillo
Journal:  Bone       Date:  2020-03-20       Impact factor: 4.398

5.  Predicting cortical bone adaptation to axial loading in the mouse tibia.

Authors:  A F Pereira; B Javaheri; A A Pitsillides; S J Shefelbine
Journal:  J R Soc Interface       Date:  2015-09-06       Impact factor: 4.118

6.  Application of subject-specific adaptive mechanical loading for bone healing in a mouse tail vertebral defect.

Authors:  Angad Malhotra; Matthias Walle; Graeme R Paul; Gisela A Kuhn; Ralph Müller
Journal:  Sci Rep       Date:  2021-01-21       Impact factor: 4.379

7.  Cortical Thickness Adaptive Response to Mechanical Loading Depends on Periosteal Position and Varies Linearly With Loading Magnitude.

Authors:  Corey J Miller; Silvia Trichilo; Edmund Pickering; Saulo Martelli; Peter Delisser; Lee B Meakin; Peter Pivonka
Journal:  Front Bioeng Biotechnol       Date:  2021-06-18

8.  The Role of the Loading Condition in Predictions of Bone Adaptation in a Mouse Tibial Loading Model.

Authors:  Vee San Cheong; Visakan Kadirkamanathan; Enrico Dall'Ara
Journal:  Front Bioeng Biotechnol       Date:  2021-06-11

9.  Spatial relationship between bone formation and mechanical stimulus within cortical bone: Combining 3D fluorochrome mapping and poroelastic finite element modelling.

Authors:  A Carrieroa; A F Pereirab; A J Wilson; S Castagno; B Javaheri; A A Pitsillides; M Marenzana; S J Shefelbine
Journal:  Bone Rep       Date:  2018-02-16

10.  A novel algorithm to predict bone changes in the mouse tibia properties under physiological conditions.

Authors:  Vee San Cheong; Ana Campos Marin; Damien Lacroix; Enrico Dall'Ara
Journal:  Biomech Model Mechanobiol       Date:  2019-11-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.