Degree of conversion of dual-cure resins light-cured through glass-fiber posts.

Francesca Cerutti1, Pier Antonio Acquaviva, Massimo Gagliani, Marco Ferrari, Francesco Mangani, Laura E Depero, Antonio Cerutti.   

Abstract

PURPOSE: To evaluate the degree of conversion (DC) of dual-curing materials used to lute glass-fiber posts in a simulated root canal polymerized by two different modalities.
METHODS: Artificial root canals were used to simulate a clinical condition to lute 45 posts by three different dual curing luting cements (Calibra, Multilink Automix and Variolink II). Two light cure modalities were chosen for each luting cement: standard (S group) 400 mW/cm2 for 120 seconds and high-power (H group) 1200 mW/cm2 for 40 seconds. Raman spectra were collected at different positions in the post surface (1, 3, 5 and 7 mm from the coronal-most portion of the post covered in cement) and the percentage degree of conversion was computed. The data were analyzed using ANOVA and post-hoc Student-Neuman-Keuls t-test (P = 0.05).
RESULTS: The DC of the tested luting composites decreased progressively while increasing the distance from the light tip. Regardless of the polymerization modality (H or S) applied. Conversely, the curing modality significantly influenced the DC of the tested materials, evidencing different responses to the same energy density: Calibra seemed to be less dependent on light-curing than the other tested materials, showing a constant behavior. Multilink Automix reached the highest DCs in the S group compared to the H mode. Variolink II showed an interesting drawback in DC at 7 mm when cured in the H model. Dual-cure materials show adequate monomer conversion but when the distance from the curing light increased, a variable, but significant lowering in conversion rate was observed. In addition, the time and power of curing appeared to be material-dependent and should be calibrated individually.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21469400

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  6 in total

1.  Fracture Resistance of Endodontically Treated Roots Restored with Fiber Posts Using Different Resin Cements- An In-vitro Study.

Authors:  Swetha Gopal; Sujatha Irodi; Deepak Mehta; Shankar Subramanya; Vinay Kumar Govindaraju
Journal:  J Clin Diagn Res       Date:  2017-02-01

2.  How the translucency of direct anatomic fiber posts affects the bond strength and microhardness of a self-adhesive luting agent in flared roots.

Authors:  Camilo Pulido; Osnara Mongruel Gomes; Alessandro Dourado Loguercio; Andrés Dávila-Sánchez; Fernando Camilotti; Gerson Kniphoff da Cruz; Cesar Augusto Galvão Arrais
Journal:  Clin Oral Investig       Date:  2022-02-15       Impact factor: 3.573

3.  Effect of Light Intensity on the Degree of Conversion of Dual-cured Resin Cement at Different Depths with the use of Translucent Fiber Posts.

Authors:  Mahmoud Bahari; Siavash Savadi Oskoee; Soodabeh Kimyai; Narmin Mohammadi; Elmira Saati Khosroshahi
Journal:  J Dent (Tehran)       Date:  2014-05-31

4.  Fourier-transform infrared spectroscopy/attenuated total reflectance analysis for the degree of conversion and shear bond strength of Transbond XT adhesive system.

Authors:  Taha Mohammed Masood; Mona Aly Abbassy; Ahmed Samir Bakry; Naof Yessen Matar; Ali Habib Hassan
Journal:  Clin Cosmet Investig Dent       Date:  2018-12-07

5.  Degree of conversion and bond strength of resin-cements to feldspathic ceramic using different curing modes.

Authors:  Veridiana Resende Novais; Luís Henrique Araújo Raposo; Rafael Resende de Miranda; Camila de Carvalho Almança Lopes; Paulo Cézar Simamoto; Carlos José Soares
Journal:  J Appl Oral Sci       Date:  2017 Jan-Feb       Impact factor: 2.698

6.  Efficacy of Fiber Post Bonding To Root Dentin after Different Obturation Techniques and Cementation Timings: In Vitro Study.

Authors:  Rami M Galal; Nada Omar; Haidy Nabil; Yousra Aly
Journal:  Open Access Maced J Med Sci       Date:  2018-09-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.