Figure 1Paradoxical para-Hisian pacing response. In the first two beats, the stimulus to atrial activation (SA) interval is different between the narrow(His bundle capture) and wide QRS beats (His bundle noncapture), suggesting a nodal response. In the next two beats the stimulus to atrial activation interval is same suggesting an extranodal response. Shown are surface ECG leads I, II, V1 and V6; high atrial electrogram (HRp); His bundle electrograms proximal (His p) and distal (His d); coronary sinus electrograms proximal (CS 9,10) to distal (CS 1,2); and right ventricular apex electrogram (RVp). The His distal recording shows pacing stimulus and a saturation artifact masking all electrograms due to high current of pacing.
Figure 2True para-Hisian pacing response. The SA interval during His bundle capture (narrow QRS beats) is longer than the SA interval during His bundle capture in figure 1. Annotations are as in Figure 1.