Literature DB >> 21465603

Prediction of preterm birth using the cervical consistency index.

M Parra-Saavedra1, L Gómez, A Barrero, G Parra, F Vergara, E Navarro.   

Abstract

OBJECTIVES: To assess the diagnostic power of a new cervical consistency index (CCI) obtained using transvaginal sonography for the prediction of spontaneous preterm birth (PTB) and to establish reference ranges for this new variable.
METHODS: Included in this prospective cross-sectional study were 1115 singleton pregnancies at 5-36 weeks of gestation. Anteroposterior cervical diameter was measured before (AP) and after (AP') application of pressure on the cervix using the transvaginal probe. The index was calculated using the formula: CCI=((AP'/AP) × 100). Cervical length was also measured. The outcomes evaluated were spontaneous PTB before 32, 34 and 37 weeks. Logistic regression and analysis of receiver-operating characteristics (ROC) curves were performed to evaluate the diagnostic power of CCI and cervical length (adjusted for gestational age). Intraclass correlation coefficients (ICCs) and Bland-Altman analysis were used to evaluate intra- and interobserver variability.
RESULTS: In the 1031 women with follow-up, the rate of spontaneous PTB before 32 weeks was 0.87%, before 34 weeks was 2.13% and before 37 weeks was 7.76% (n=80). There were 31 (3.01%) iatrogenic PTBs before 37 weeks. An inverse linear correlation between gestational age and CCI was observed, with regression equation: CCI (in %)=89.8 - 1.35 × (GA in weeks); r(2)=0.66, P<0.001. Cervical length showed an inverse quadratic, though non-significant, relationship with gestational age: CL (in mm)=31.084 - 0.0278× (GA in weeks)(2) + 1.0772× (GA in weeks); r(2)=0.076, P<0.14. The intra- and interobserver ICCs for CCI were 0.99 (95% CI, 0.988-0.994) and 0.98 (95% CI, 0.973-0.987), respectively. The area under the ROC curve for CCI in the prediction of spontaneous PTB before 32 weeks was 0.947, for spontaneous PTB before 34 weeks it was 0.943 and for spontaneous PTB before 37 weeks it was 0.907. For a 5% screen-positive rate, CCI had a sensitivity of 67%, 64% and 45% for prediction of spontaneous PTB before 32, 34 and 37 weeks, respectively, with equivalent values of 11%, 9% and 11% for cervical length.
CONCLUSIONS: CCI shows a clear inverse linear relationship with GA. Assessment of CCI is reproducible and is effective in the prediction of spontaneous PTB. This new variable appears to provide better prediction of spontaneous PTB than does cervical length.
Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 21465603     DOI: 10.1002/uog.9010

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  22 in total

1.  Statistical analysis of shear wave speed in the uterine cervix.

Authors:  Lindsey C Carlson; Helen Feltovich; Mark L Palmeri; Alejandro Muñoz del Rio; Timothy J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-10       Impact factor: 2.725

2.  The clinical significance of a positive Amnisure test in women with preterm labor and intact membranes.

Authors:  Seung Mi Lee; Roberto Romero; Jeong Woo Park; Sun Min Kim; Chan-Wook Park; Steven J Korzeniewski; Tinnakorn Chaiworapongsa; Bo Hyun Yoon
Journal:  J Matern Fetal Neonatal Med       Date:  2012-04-25

3.  Development of an ultrasonic method to detect cervical remodeling in vivo in full-term pregnant women.

Authors:  Barbara L McFarlin; Jennifer Balash; Viksit Kumar; Timothy A Bigelow; Xavier Pombar; Jacques S Abramowicz; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2015-05-23       Impact factor: 2.998

Review 4.  The mechanical role of the cervix in pregnancy.

Authors:  Kristin M Myers; Helen Feltovich; Edoardo Mazza; Joy Vink; Michael Bajka; Ronald J Wapner; Timothy J Hall; Michael House
Journal:  J Biomech       Date:  2015-03-11       Impact factor: 2.712

5.  A continuous fiber distribution material model for human cervical tissue.

Authors:  Kristin M Myers; Christine P Hendon; Yu Gan; Wang Yao; Kyoko Yoshida; Michael Fernandez; Joy Vink; Ronald J Wapner
Journal:  J Biomech       Date:  2015-03-14       Impact factor: 2.712

Review 6.  Cervical elastography during pregnancy: a critical review of current approaches with a focus on controversies and limitations.

Authors:  Arrigo Fruscalzo; Edoardo Mazza; Helen Feltovich; Ralf Schmitz
Journal:  J Med Ultrason (2001)       Date:  2016-06-03       Impact factor: 1.314

7.  Strain at the internal cervical os assessed with quasi-static elastography is associated with the risk of spontaneous preterm delivery at ≤34 weeks of gestation.

Authors:  Edgar Hernandez-Andrade; Maynor Garcia; Hyunyoung Ahn; Steven J Korzeniewski; Homam Saker; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2015-11       Impact factor: 1.901

8.  Cervical strain determined by ultrasound elastography and its association with spontaneous preterm delivery.

Authors:  Edgar Hernandez-Andrade; Roberto Romero; Steven J Korzeniewski; Hyunyoung Ahn; Alma Aurioles-Garibay; Maynor Garcia; Alyse G Schwartz; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan
Journal:  J Perinat Med       Date:  2014-03       Impact factor: 1.901

Review 9.  The pathophysiology of human premature cervical remodeling resulting in spontaneous preterm birth: Where are we now?

Authors:  Joy Vink; Mirella Mourad
Journal:  Semin Perinatol       Date:  2017-08-18       Impact factor: 3.300

Review 10.  Screening for spontaneous preterm birth and resultant therapies to reduce neonatal morbidity and mortality: A review.

Authors:  Angelica V Glover; Tracy A Manuck
Journal:  Semin Fetal Neonatal Med       Date:  2017-12-09       Impact factor: 3.926

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.