Literature DB >> 21461699

Study of the in vitro corrosion behavior and biocompatibility of Zr-2.5Nb and Zr-1.5Nb-1Ta (at%) crystalline alloys.

F Rosalbino1, D Macciò, P Giannoni, R Quarto, A Saccone.   

Abstract

The in vitro corrosion behavior and biocompatibility of two Zr alloys, Zr-2.5Nb, employed for the manufacture of CANDU reactor pressure tubes, and Zr-1.5Nb-1Ta (at%), for use as implant materials have been assessed and compared with those of Grade 2 Ti, which is known to be a highly compatible metallic biomaterial. The in vitro corrosion resistance was investigated by open circuit potential and electrochemical impedance spectroscopy (EIS) measurements, as a function of exposure time to an artificial physiological environment (Ringer's solution). Open circuit potential values indicated that both the Zr alloys and Grade 2 Ti undergo spontaneous passivation due to spontaneously formed oxide film passivating the metallic surface, in the aggressive environment. It also indicated that the tendency for the formation of a spontaneous oxide is greater for the Zr-1.5Nb-1Ta alloy and that this oxide has better corrosion protection characteristics than the ones formed on Grade 2 Ti or on the Zr-2.5Nb alloy. EIS study showed high impedance values for all samples, increasing with exposure time, indicating an improvement in corrosion resistance of the spontaneous oxide film. The fit obtained suggests a single passive film presents on the metals surface, improving their resistance with exposure time, presenting the highest values to the Zr-1.5Nb-1Ta alloy. For the biocompatibility analysis human osteosarcoma cell line (Saos-2) and human primary bone marrow stromal cells (BMSC) were used. Biocompatibility tests showed that Saos-2 cells grow rapidly, independently of the surface, due to reduced dependency from matrix deposition and microenvironment recognition. BMSC instead display a reduced proliferation, possibly caused by a reduced crosstalk with the metal surface microenvironment. However, once the substrate has been colonized, BMSC seem to respond properly to osteoinduction stimuli, thus supporting a substantial equivalence in the biocompatibility among the Zr alloys and Grade 2 titanium. In summary, high in vitro corrosion resistance together with satisfactory biocompatibility make the Zr-2.5Nb and Zr-1.5Nb-1Ta crystalline alloys promising biomaterials for surgical implants.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21461699     DOI: 10.1007/s10856-011-4301-z

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  34 in total

1.  Characterization of adhesion and differentiation markers of osteogenic marrow stromal cells.

Authors:  R Marom; I Shur; R Solomon; Dafna Benayahu
Journal:  J Cell Physiol       Date:  2005-01       Impact factor: 6.384

2.  The influence of an in vitro generated bone-like extracellular matrix on osteoblastic gene expression of marrow stromal cells.

Authors:  Quynh P Pham; F Kurtis Kasper; L Scott Baggett; Robert M Raphael; John A Jansen; Antonios G Mikos
Journal:  Biomaterials       Date:  2008-03-25       Impact factor: 12.479

3.  Initial hemocompatibility studies of titanium and zirconium alloys: prekallikrein activation, fibrinogen adsorption, and their correlation with surface electrochemical properties.

Authors:  Y H Yun; V T Turitto; K P Daigle; P Kovacs; J A Davidson; S M Slack
Journal:  J Biomed Mater Res       Date:  1996-09

Review 4.  Bone sialoprotein.

Authors:  B Ganss; R H Kim; J Sodek
Journal:  Crit Rev Oral Biol Med       Date:  1999

5.  Titanium substrata composition influences osteoblastic phenotype: In vitro study.

Authors:  H Zreiqat; C R Howlett
Journal:  J Biomed Mater Res       Date:  1999-12-05

6.  Enhanced osteoblast response to hydrophilic strontium and/or phosphate ions-incorporated titanium oxide surfaces.

Authors:  Jin-Woo Park; Youn-Jeong Kim; Je-Hee Jang
Journal:  Clin Oral Implants Res       Date:  2010-02-01       Impact factor: 5.977

7.  Runx2- and histone deacetylase 3-mediated repression is relieved in differentiating human osteoblast cells to allow high bone sialoprotein expression.

Authors:  Virginie Lamour; Cédric Detry; Christelle Sanchez; Yves Henrotin; Vincent Castronovo; Akeila Bellahcène
Journal:  J Biol Chem       Date:  2007-10-22       Impact factor: 5.157

8.  Effects of titanium surface roughness on mesenchymal stem cell commitment and differentiation signaling.

Authors:  Stefania Balloni; Edoardo Maria Calvi; Francesco Damiani; Giovanni Bistoni; Mario Calvitti; Paola Locci; Ennio Becchetti; Lorella Marinucci
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Jul-Aug       Impact factor: 2.804

9.  Histomorphometry of initial bone healing around zirconium implants in rats.

Authors:  R L Cabrini; M B Guglielmotti; J C Almagro
Journal:  Implant Dent       Date:  1993       Impact factor: 2.454

10.  Modulation of osteoblast behaviour by tenascin.

Authors:  E J Mackie; S Ramsey
Journal:  J Cell Sci       Date:  1996-06       Impact factor: 5.285

View more
  7 in total

1.  Quaternary Ti-20Nb-10Zr-5Ta alloy during immersion in simulated physiological solutions: formation of layers, dissolution and biocompatibility.

Authors:  Ingrid Milošev; Julija Hmeljak; Gregor Žerjav; Andrej Cör; Jose Maria Calderon Moreno; Monica Popa
Journal:  J Mater Sci Mater Med       Date:  2014-01-23       Impact factor: 3.896

2.  Titanium Ions Release from an Innovative Titanium-Magnesium Composite: an in Vitro Study.

Authors:  Zlatko Stanec; Jasna Halambek; Krešimir Maldini; Martin Balog; Peter Križik; Zdravko Schauperl; Amir Ćatić
Journal:  Acta Stomatol Croat       Date:  2016-03

3.  Osteoblastic behavior to zirconium coating on Ti-6Al-4V alloy.

Authors:  Bo-Ah Lee; Hae-Jin Kim; Yun-Ze Xuan; Yeong-Joon Park; Hyun-Ju Chung; Young-Joon Kim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

4.  Effect of porous tantalum on promoting the osteogenic differentiation of bone marrow mesenchymal stem cells in vitro through the MAPK/ERK signal pathway.

Authors:  Xiaojie Dou; Xiaowei Wei; Ge Liu; Shuai Wang; Yongxiang Lv; Junlei Li; Zhijie Ma; Guoshuang Zheng; Yikai Wang; Minghui Hu; Weiting Yu; Dewei Zhao
Journal:  J Orthop Translat       Date:  2019-04-15       Impact factor: 5.191

5.  Effect of DC Plasma Electrolytic Oxidation on Surface Characteristics and Corrosion Resistance of Zirconium.

Authors:  Maciej Sowa; Wojciech Simka
Journal:  Materials (Basel)       Date:  2018-05-03       Impact factor: 3.623

6.  Corrosion Behavior of Titanium in Simulated Body Solutions with the Addition of Biomolecules.

Authors:  Milan B Radovanović; Žaklina Z Tasić; Ana T Simonović; Marija B Petrović Mihajlović; Milan M Antonijević
Journal:  ACS Omega       Date:  2020-05-29

7.  Plasma Electrolytic Oxidation of Zr-1%Nb Alloy: Effect of Sodium Silicate and Boric Acid Addition to Calcium Acetate-Based Electrolyte.

Authors:  Veta Aubakirova; Ruzil Farrakhov; Vasily Astanin; Arseny Sharipov; Mikhail Gorbatkov; Evgeny Parfenov
Journal:  Materials (Basel)       Date:  2022-03-08       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.