Abstract
BACKGROUND: Diisocyanates are widely used in surface coatings, polyurethane (PUR) foams, adhesives, resins, elastomers, binders, and sealants. Isocyanate exposure is irritative to the skin, mucous membranes, eyes, and respiratory tract. The most common adverse health outcome associated with isocyanate exposure is asthma due to sensitization.Entities:
Keywords: Diisocyanate; dry bulb temperature; hexamethylene diisocyanate concentration; regression; relative humidity
Year: 2010 PMID: 21461158 PMCID: PMC3062018 DOI: 10.4103/0019-5278.75693
Source DB: PubMed Journal: Indian J Occup Environ Med ISSN: 0973-2284
Values of indoor air variables in the HDI polyurethane factories
| Variables | Factory codes | Average | ||||
|---|---|---|---|---|---|---|
| H1 | H2 | H3 | H4 | H5 | ||
| HDI concentration ( | 96 | 92 | 90 | 90 | 88 | 91.2 |
| Min | 67 | 66 | 66 | 64 | 61 | 64.8 |
| Mean | 82.2 | 79.8 | 78.7 | 77 | 76.7 | 78.8 |
| Relative humidity (%), max | 52 | 52 | 45 | 45 | 40 | 46.8 |
| Min | 32 | 31 | 31 | 31 | 31 | 31.2 |
| Mean | 40.5 | 40 | 37 | 37 | 34 | 37.7 |
| Dry bulb temperature (°C), max | 33 | 32 | 32 | 32 | 30 | 31.8 |
| Min | 25 | 24 | 24 | 24 | 23 | 24 |
| Mean | 29.3 | 27.8 | 28.7 | 28.7 | 27.1 | 28.3 |
| Dimension of factory (m3) | 5000 | 6100 | 7400 | 9000 | 9800 | 7460 |
| Altitude (m) | 1200 | 1200 | 1100 | 890 | 22 | 882 |
Max: maximum, min: minimum, NIOSH guideline value: 35(µg/m3)
Correlation result for HDI concentration and psychrometric parameters and factory parameters
| HDI ( | RH (%) | Td (°C) | D (m3) | Alt (m) | ||
|---|---|---|---|---|---|---|
| HDI ( | Pearson Correlation | 1 | 0.739 | 0.88 | -0.887 | 0.85 |
| Sig. (2-tailed) | . | 0.0001 | 0.0001 | 0.0001 | 0.0001 | |
| N | 100 | 100 | 100 | 100 | 100 | |
| RH (%) | Pearson Correlation | 0.739 | 1 | 0.639 | -0.687 | 0.744 |
| Sig. (2-tailed) | 0.0001 | . | 0.0001 | 0.0001 | 0.0001 | |
| N | 100 | 100 | 100 | 100 | 100 | |
| Td (°C) | Pearson Correlation | 0.88 | 0.639 | 1 | -0.963 | 0.719 |
| Sig. (2-tailed) | 0.0001 | 0.0001 | . | 0.0001 | 0.001 | |
| N | 100 | 100 | 100 | 100 | 100 | |
| D (m3) | Pearson Correlation | -0.887 | -0.687 | -0.963 | 1 | -0.812 |
| Sig. (2-tailed) | 0.0001 | 0.0001 | 0.0001 | . | 0.0001 | |
| N | 100 | 100 | 100 | 100 | 100 | |
| Alt (m) | Pearson Correlation | 0.85 | 0.744 | 0.719 | -0.812 | 1 |
| Sig. (2-tailed) | 0.0001 | 0.0001 | 0.0001 | 0.0001 | . | |
| N | 100 | 100 | 100 | 100 | 100 |
Correlation is significant at the 0.05 level (2-tailed).
Regression model summary of HDI
| Model | r | Adjusted | |
|---|---|---|---|
| 0.915 | 0.837 | 0.83 |
Predictors: (constant), altitude (m), dimension of factory (m3), relative humidity (%), dry bulb temperature (°C)
Regression model for HDI polyurethane factories’ factors
| Model | Mean square | ||
|---|---|---|---|
| Regression | 1155.895 | 121.934 | 0.0001 |
| Residual | 9.48 | ||
| Total | 0 |
Predictors: (constant), altitude (m), dimension of factory (m3), relative humidity (%), dry bulb temperature (°C), dependent Variable: HDI concentration (µg/m3)
Result of regression analysis between HDI concentration and polyurethane indoor air parameters
| Model | Coefficients | |||
|---|---|---|---|---|
| B | SE | |||
| (Constant) | 43.267 | 17.837 | 2.426 | 0.017 |
| Relative humidity (%) | 0.367 | 0.071 | 5.182 | 0.0001 |
| Dry bulb temperature (°C) | 1.112 | 0.399 | 2.785 | 0.006 |
| Dimension of factory (m3) | –0.001 | 0.001 | –1.479 | 0.142 |
| Altitude (m) | 0.003 | 0.002 | 1.475 | 0.144 |
Dependent Variable: HDI concentration (µg/m3)
The collinearity statistical model coefficients
| Model | Coefficients | t | Collinearity statistics | |||
|---|---|---|---|---|---|---|
| B | SE | Tolerance | VIF | |||
| (Constant) | 27.771 | 2.638 | 10.528 | 0.0001 | ||
| Relative humidity (%) | 0.368 | 0.067 | 5.454 | 0.0001 | 0.592 | 1.689 |
| Dry bulb temperature (°C) | 1.492 | 0.119 | 12.588 | 0.0001 | 0.592 | 1.689 |
Dependent variable: HDI concentration (µg/m3)
Figure 1Relationship between HDI concentration and psychrometric parameters (relative humidity and dry bulb temperature)