Literature DB >> 21456800

A new method for wideband characterization of resonator-based sensing platforms.

Farasat Munir1, Adam Wathen, William D Hunt.   

Abstract

A new approach to the electronic instrumentation for extracting data from resonator-based sensing devices (e.g., microelectromechanical, piezoelectric, electrochemical, and acoustic) is suggested and demonstrated here. Traditionally, oscillator-based circuitry is employed to monitor shift in the resonance frequency of the resonator. These circuits give a single point measurement at the frequency where the oscillation criterion is met. However, the resonator response itself is broadband and contains much more information than a single point measurement. Here, we present a method for the broadband characterization of a resonator using white noise as an excitation signal. The resonator is used in a two-port filter configuration, and the resonator output is subjected to frequency spectrum analysis. The result is a wideband spectral map analogous to the magnitude of the S21 parameters of a conventional filter. Compared to other sources for broadband excitation (e.g., frequency chirp, multisine, or narrow time domain pulse), the white noise source requires no design of the input signal and is readily available for very wide bandwidths (1 MHz-3 GHz). Moreover, it offers simplicity in circuit design as it does not require precise impedance matching; whereas such requirements are very strict for oscillator-based circuit systems, and can be difficult to fulfill. This results in a measurement system that does not require calibration, which is a significant advantage over oscillator circuits. Simulation results are first presented for verification of the proposed system, followed by measurement results with a prototype implementation. A 434 MHz surface acoustic wave (SAW) resonator and a 5 MHz quartz crystal microbalance (QCM) are measured using the proposed method, and the results are compared to measurements taken by a conventional bench-top network analyzer. Maximum relative differences in the measured resonance frequencies of the SAW and QCM resonators are 0.0004% and 0.002%, respectively. The ability to track a changing sensor response is demonstrated by inducing temperature variations and measuring resonance frequency simultaneously using the proposed technique in parallel with a network analyzer. The relative difference between the two measurements is about 5.53 ppm, highlighting the impressive accuracy of the proposed system. Using commercially available digital signal processors (DSPs), we believe that this technique can be implemented as a system-on-a-chip solution resulting in a very low cost, easy to use, portable, and customizable sensing system. In addition, given the simplicity of the signal and circuit design, and its immunity to other common interface concerns (injection locking, oscillator interference, and drift, etc.), this method is better suited to accommodating array-based systems.

Mesh:

Year:  2011        PMID: 21456800      PMCID: PMC3081863          DOI: 10.1063/1.3567005

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  11 in total

1.  The problem of uniqueness of fit for viscoelastic films on thickness-shear mode resonator surfaces.

Authors:  A R Hillman; A Jackson; S J Martin
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

2.  A novel microgravimetric DNA sensor with high sensitivity.

Authors:  Tao Liu; Ji'an Tang; Meimei Han; Long Jiang
Journal:  Biochem Biophys Res Commun       Date:  2003-04-25       Impact factor: 3.575

3.  Zeptogram-scale nanomechanical mass sensing.

Authors:  Y T Yang; C Callegari; X L Feng; K L Ekinci; M L Roukes
Journal:  Nano Lett       Date:  2006-04       Impact factor: 11.189

4.  Is an oscillator-based measurement adequate in a liquid environment?

Authors:  Ralf Borngräber; Jens Schröder; Ralf Lucklum; Peter Hauptmann
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-09       Impact factor: 2.725

5.  Development of circuit for measuring both Q variation and resonant frequency shift of quartz crystal microbalance.

Authors:  T Nakamoto; T Kobayashi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1994       Impact factor: 2.725

6.  Injection locking techniques for a 1-GHz digital receiver using acoustic-wave devices.

Authors:  P J Edmonson; P M Smith; C K Campbell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

7.  Convergence of dissipation and impedance analysis of quartz crystal microbalance studies.

Authors:  Yaozhong Zhang; Binyang Du; Xinan Chen; Hongwei Ma
Journal:  Anal Chem       Date:  2009-01-15       Impact factor: 6.986

8.  Modeling the Responses of Thickness-Shear Mode Resonators under Various Loading Conditions.

Authors:  H L Bandey; S J Martin; R W Cernosek; A R Hillman
Journal:  Anal Chem       Date:  1999-06-01       Impact factor: 6.986

9.  Characterization of serum biomarkers for detection of early stage ovarian cancer.

Authors:  Katherine R Kozak; Feng Su; Julian P Whitelegge; Kym Faull; Srinivasa Reddy; Robin Farias-Eisner
Journal:  Proteomics       Date:  2005-11       Impact factor: 3.984

10.  Characterization of humoral responses of ovarian cancer patients: antibody subclasses and antigenic components.

Authors:  Douglas D Taylor; Safinur Atay; Daniel S Metzinger; Cicek Gercel-Taylor
Journal:  Gynecol Oncol       Date:  2009-11-30       Impact factor: 5.482

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.