Literature DB >> 21452718

Performance evaluation of real-time motion tracking using positron emission fiducial markers.

Marc Chamberland1, Richard Wassenaar, Benjamin Spencer, Tong Xu.   

Abstract

PURPOSE: Tumor motion due to patient breathing is a factor that limits the accuracy of dose distribution in radiotherapy. One of the methods to improve the accuracy is by applying respiratory gating or tumor tracking. Both techniques require a precise determination of the spatial location of the tumor. We present an experimental evaluation of the performance of PeTrack, a technique that can track internal fiducial markers in real-time for tumor tracking.
METHODS: PeTrack uses position sensitive detectors to record annihilation coincidence gamma rays from fiducial positron emission markers implanted in or around the tumor. It uses an expectation-maximization clustering algorithm to track the position of the markers. A normalized least mean square adaptive filter was used to predict the position of the markers 100 and 200 ms in the future. We evaluated the performance of the tracking and of the prediction by using a dynamic anthropomorphic thorax phantom to generate three-dimensional (3D) motion of three fiducial markers. The algorithm was run with four different data sets. In the first run, the motion of the markers was based on a sinusoidal model of respiratory motion. Three additional runs were done with motion based on patient breathing data.
RESULTS: In the case of the sinusoidal model, the average 3D root mean square error for all markers was 0.44 mm. For the three runs based on patient breathing data, the precision of the 3D localization was 0.49 mm. At a latency of 100 ms, the average 3D prediction error was 1.3 +/- 0.6 mm for the sinusoidal model and for the three patient breathing runs. At a latency of 200 ms, the average 3D prediction errors were 1.7 +/- 0.8 mm for the sinusoidal model and 1.4 +/- 0.7 mm for the breathing runs.
CONCLUSIONS: We conclude that PeTrack can track multiple fiducial markers in real-time with an accuracy and precision smaller than 2 mm. PeTrack can have a direct application in tumor tracking for radiation therapy.

Entities:  

Mesh:

Year:  2011        PMID: 21452718     DOI: 10.1118/1.3537206

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Toward a planning scheme for emission guided radiation therapy (EGRT): FDG based tumor tracking in a metastatic breast cancer patient.

Authors:  Qiyong Fan; Akshay Nanduri; Jaewon Yang; Tokihiro Yamamoto; Billy Loo; Edward Graves; Lei Zhu; Samuel Mazin
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

2.  Advances in 4D radiation therapy for managing respiration: part II - 4D treatment planning.

Authors:  Mihaela Rosu; Geoffrey D Hugo
Journal:  Z Med Phys       Date:  2012-07-15       Impact factor: 4.820

3.  First-in-human imaging using a MR-compatible e4D ultrasound probe for motion management of radiotherapy.

Authors:  Bryan P Bednarz; Sydney Jupitz; Warren Lee; David Mills; Heather Chan; Timothy Fiorillo; James Sabitini; David Shoudy; Aqsa Patel; Jhimli Mitra; Shourya Sarcar; Bo Wang; Andrew Shepard; Charles Matrosic; James Holmes; Wesley Culberson; Michael Bassetti; Patrick Hill; Alan McMillan; James Zagzebski; L Scott Smith; Thomas K Foo
Journal:  Phys Med       Date:  2021-07-01       Impact factor: 3.119