DESIGN: Biomechanical Cadaveric Study.
OBJECTIVE: To characterize the pullout strength of calcium phosphate cement augmented screws between 0 and 6 minutes after cement injection. SUMMARY OF BACKGROUND DATA: Earlier studies with calcium phosphate cement on pedicle screws inserted into a metal mold or sawbone have shown that the augmentation strength can be affected by the time between cement injection and screw insertion. However, these studies only compared soft cement to completely hardened cement with extended waiting times. These extended waiting times are impractical in live spinal surgeries.
METHODS: Twenty-four pedicle screws were inserted and pulled out axially from cadaveric bone to make revision models. The 24 screw holes were randomly divided into 4 groups, with each group having 6 holes. For each group, identical pedicle screws were inserted at 0, 2, 4, and 6 minutes after injection with bioresorbable calcium phosphate cement (CPC). After 24 hours, the augmented screws were pulled out axially and their pullout strengths were compared.
RESULTS: The difference between secondary pullout strength and primary pullout strength increased up to 4 minutes after cement injection but decreased after 6 minutes but without statistical difference among the 4 time settings (P>0.3).
CONCLUSIONS: The augmented screws had similar fixation strength regardless of the time between cement mixture and screw insertion as long as they are inserted within 6 minutes. Augmentation power tends to increase up to 4 minutes after cement injection but decreases after 6 minutes.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21445025     DOI: 10.1097/BSD.0b013e3181dd7961

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  10 in total

1.  Self-setting calcium orthophosphate formulations.

Authors:  Sergey V Dorozhkin
Journal:  J Funct Biomater       Date:  2013-11-12

2.  Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength.

Authors:  Julian L Wichmann; Christian Booz; Stefan Wesarg; Ralf W Bauer; J Matthias Kerl; Sebastian Fischer; Thomas Lehnert; Thomas J Vogl; M Fawad Khan; Konstantinos Kafchitsas
Journal:  Eur Radiol       Date:  2014-12-07       Impact factor: 5.315

Review 3.  Pedicle screw augmentation in osteoporotic spine: indications, limitations and technical aspects.

Authors:  S Hoppe; M J B Keel
Journal:  Eur J Trauma Emerg Surg       Date:  2016-12-19       Impact factor: 3.693

4.  Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw.

Authors:  Evangelos Christodoulou; Suresh Chinthakunta; Divya Reddy; Saif Khalil; Thomas Apostolou; Philipp Drees; Konstantinos Kafchitsas
Journal:  Scoliosis       Date:  2015-05-01

5.  Staged Correction of Severe Thoracic Kyphosis in Patients with Multilevel Osteoporotic Vertebral Compression Fractures.

Authors:  Eyal Behrbalk; Ofir Uri; Yoram Folman; Marcus Rickert; Radek Kaiser; Bronek Maximilian Boszczyk
Journal:  Global Spine J       Date:  2015-12-02

6.  A novel injectable calcium phosphate-based nanocomposite for the augmentation of cannulated pedicle-screw fixation.

Authors:  Haolin Sun; Chun Liu; Huiling Liu; Yanjie Bai; Zheng Zhang; Xuwen Li; Chunde Li; Huilin Yang; Lei Yang
Journal:  Int J Nanomedicine       Date:  2017-04-27

7.  A study on the use of the Osstell apparatus to evaluate pedicle screw stability: An in-vitro study using micro-CT.

Authors:  Daisuke Nakashima; Ken Ishii; Morio Matsumoto; Masaya Nakamura; Takeo Nagura
Journal:  PLoS One       Date:  2018-06-28       Impact factor: 3.240

Review 8.  Review of Sickle Cell Disease and Spinal Pathology.

Authors:  Hayeem L Rudy; David Yang; Andrew D Nam; Woojin Cho
Journal:  Global Spine J       Date:  2018-09-17

9.  Improved fixation stability for repairing pedicle screw loosening using a modified cement filling technique in porcine vertebrae.

Authors:  Ming-Kai Hsieh; Yun-Da Li; Yu-Chen Li; Mu-Yi Liu; Tsung-Ting Tsai; Po-Liang Lai; Ching-Lung Tai
Journal:  Sci Rep       Date:  2022-02-17       Impact factor: 4.379

10.  The Biomechanical Properties of Cement-Augmented Pedicle Screws for Osteoporotic Spines.

Authors:  Yuetian Wang; Lei Yang; Chunde Li; Haolin Sun
Journal:  Global Spine J       Date:  2021-02-22
  10 in total