OBJECTIVES: The aim of the present prospective clinical study was to evaluate the match between the positions and axes of the virtually planned and the placed implants using laboratory-based surgical guides generated from cone beam computed tomography (CBCT).
MATERIALS AND METHODS: A total of 132 implants were placed with the aid of 3D-based transfer templates in 52 consecutive partially edentulous patients between April 2008 and March 2010. After individual adaptation of the scan templates and CBCT scanning, the acquired data for virtual implant planning and simulation were processed using the med3D software program. After finalizing the virtual placement of the implants the radiographic templates were converted into operative guides containing titanium sleeves for cavity preparation. Preoperative planning was merged with postoperative CBCT data to identify linear and angular deviations between virtually planned and placed implants.
RESULTS: Compared with the planned implants the installed implants showed linear deviations in the median at the neck and apex of 0.27 mm (range 0.01-0.97 mm), and of 0.46 mm (range 0.03-1.38 mm), respectively. The angle deviation was 1.84° in median, with a range of 0.07-6.26°. The extent of deviation depends on the size of the tooth gap and the distribution of the remaining teeth.
CONCLUSION: The results of this study suggested that laboratory-fabricated surgical guides using CBCT data may be reliable in implant placement under prosthodontic considerations in partial edentulism.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21443593     DOI: 10.1111/j.1600-0501.2011.02176.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Accuracy and eligibility of CBCT to digitize dental plaster casts.

Authors:  Kathrin Becker; Ulf Schmücker; Frank Schwarz; Dieter Drescher
Journal:  Clin Oral Investig       Date:  2017-12-02       Impact factor: 3.573

2.  3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph; Jens Dreyhaupt; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-01-22       Impact factor: 3.573

3.  Accuracy of computer-assisted implant placement with insertion templates.

Authors:  Eleni Naziri; Alexander Schramm; Frank Wilde
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2016-05-13

4.  Computer-aided autotransplantation of teeth with 3D printed surgical guides and arch bar: a preliminary experience.

Authors:  Wei He; Kaiyue Tian; Xiaoyan Xie; Enbo Wang; Nianhui Cui
Journal:  PeerJ       Date:  2018-11-22       Impact factor: 2.984

5.  Concept description and accuracy evaluation of a moldable surgical targeting system.

Authors:  Thomas S Rau; Sina Witte; Lea Uhlenbusch; Lüder A Kahrs; Thomas Lenarz; Omid Majdani
Journal:  J Med Imaging (Bellingham)       Date:  2021-02-19

6.  Fully Digital Workflow for Planning Static Guided Implant Surgery: A Prospective Accuracy Study.

Authors:  Chia-Cheng Lin; Ching-Zong Wu; Mao-Suan Huang; Chiung-Fang Huang; Hsin-Chung Cheng; Dayen Peter Wang
Journal:  J Clin Med       Date:  2020-04-01       Impact factor: 4.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.