Literature DB >> 21441725

3D MR cisternography to identify distal dural rings: comparison of 3D-CISS and 3D-SPACE sequences.

Yoshiyuki Watanabe1, Akari Makidono, Miho Nakamura, Yukihisa Saida.   

Abstract

PURPOSE: The distal dural ring (DDR) is an anatomical landmark used to distinguish intra- and extradural aneurysms. We investigated identification of the DDR using 2 three-dimensional (3D) magnetic resonance (MR) cisternography sequences--3D constructive interference in steady state (CISS) and 3D sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE)--at 3.0 tesla.
METHODS: Ten healthy adult volunteers underwent imaging with 3D-CISS, 3D-SPACE, and time-of-flight (TOF) MR angiography (TOF-MRA) sequences at 3.0T. We analyzed DDR identification and internal carotid artery (ICA) signal intensity and classified the shape of the carotid cave.
RESULTS: We identified the DDR using both 3D-SPACE and 3D-CISS, with no significant difference between the sequences. Visualization of the outline of the ICA in the cavernous sinus (CS) was significantly clearer with 3D-SPACE than 3D-CISS. In the CS and petrous portions, signal intensity was lower with 3D-SPACE, and the flow void was poor with 3D-CISS in some subjects.
CONCLUSION: We identified the DDR with both 3D-SPACE and 3D-CISS, but the superior contrast of the ICA in the CS using 3D-SPACE suggests the superiority of this sequence for evaluating the DDR.

Entities:  

Mesh:

Year:  2011        PMID: 21441725     DOI: 10.2463/mrms.10.29

Source DB:  PubMed          Journal:  Magn Reson Med Sci        ISSN: 1347-3182            Impact factor:   2.471


  10 in total

1.  Accuracy for predicting adhesion between meningioma and the brain by using brain surface motion imaging: comparison between single and double acquisition methods.

Authors:  Toshiaki Taoka; Syuichi Yamada; Masahiko Sakamoto; Toshiaki Akashi; Toshiteru Miyasaka; Tomoko Ochi; Takeshi Wada; Masato Uchikoshi; Hiroyuki Nakase; Kimihiko Kichikawa
Journal:  Neuroradiology       Date:  2012-06-23       Impact factor: 2.804

2.  Junctional Internal Carotid Artery Aneurysms: The Schrödinger's Cat of Vascular Neurosurgery.

Authors:  Andrew P Carlson; Harry R van Loveren; A Samy Youssef; Siviero Agazzi
Journal:  J Neurol Surg B Skull Base       Date:  2014-11-26

3.  Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery.

Authors:  Seisaku Kanayama; Takayuki Hara; Yusuke Hamada; Yuji Matsumaru
Journal:  Neuroradiology       Date:  2014-11-05       Impact factor: 2.804

4.  Sectional anatomy of the abducens nerve: according to 3D-SPACE magnetic resonance sequences correlated with cryosectional specimens.

Authors:  Chao Li; Yuchun Tang; Haitao Ge; Xiangtao Lin; Bo Sun; Lei Feng; Shutao Liu; Cheng Liu; Changhu Liang; Zhonghe Zhang; Shuwei Liu
Journal:  Surg Radiol Anat       Date:  2015-03-03       Impact factor: 1.246

Review 5.  Intrathecal gadolinium-enhanced MR cisternography: a comprehensive review.

Authors:  O Algin; B Turkbey
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-19       Impact factor: 3.825

6.  Effective performance of contrast enhanced SPACE imaging in clearly depicting the margin of pituitary adenoma.

Authors:  Yue Wu; Jing Wang; Zhenwei Yao; Zhong Yang; Zengyi Ma; Yongfei Wang
Journal:  Pituitary       Date:  2015-08       Impact factor: 4.107

7.  Intrathecal gadolinium-enhanced MR cisternography in patients with otorhinorrhea: 10-year experience of a tertiary referral center.

Authors:  Sebahat Nacar Dogan; Osman Kizilkilic; Burak Kocak; Cihan Isler; Civan Islak; Naci Kocer
Journal:  Neuroradiology       Date:  2018-03-23       Impact factor: 2.804

8.  Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences.

Authors:  Murat Ucar; Nil Tokgoz; Cagri Damar; Ayse Gul Alimli; Fatih Oncu
Journal:  Jpn J Radiol       Date:  2015-01-07       Impact factor: 2.374

9.  Evaluation of aqueductal stenosis by 3D sampling perfection with application-optimized contrasts using different flip angle evolutions sequence: preliminary results with 3T MR imaging.

Authors:  O Algin; B Turkbey
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-15       Impact factor: 3.825

10.  Evaluation of schwannoma using the 3D-SPACE sequence: comparison with the 3D-CISS sequence in 3T-MRI

Authors:  Enes Gürün; İsmail Akdulum; Pınar Kılıç; Nil Tokgöz; Murat Uçar
Journal:  Turk J Med Sci       Date:  2021-06-28       Impact factor: 0.973

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.