AIM: To compare inhaled corticosteroid (ICS) inhaler type with user technique and ICS medication adherence among adults with asthma. METHODS: We classified 270 adults into two groups by ICS device type: metered-dose inhaler (MDI) or dry powder inhaler (DPI). Inhaler technique was assessed using standardised checklists. Medication adherence was evaluated using the Medication Adherence Report Scale (MARS). Differences in inhaler technique and MARS score among patients using MDIs versus DPIs were evaluated. RESULTS: Univariate analysis showed no difference in technique scores between the groups (p=0.46), but better ICS adherence among DPI users (p=0.001). In multivariable analysis, DPI use remained significantly associated with higher rates of adherence (OR 2.2; 95% CI 1.2 to 3.8) but not with inhaler technique (-0.2; 95% CI -0.5 to 0.1) after adjusting for potential confounders. CONCLUSIONS: Type of inhaler device appears to be associated with adherence to asthma controller medications. Prospective studies are needed to elucidate further the potential effect of the type of ICS delivery device on asthma self-management.
AIM: To compare inhaled corticosteroid (ICS) inhaler type with user technique and ICS medication adherence among adults with asthma. METHODS: We classified 270 adults into two groups by ICS device type: metered-dose inhaler (MDI) or dry powder inhaler (DPI). Inhaler technique was assessed using standardised checklists. Medication adherence was evaluated using the Medication Adherence Report Scale (MARS). Differences in inhaler technique and MARS score among patients using MDIs versus DPIs were evaluated. RESULTS: Univariate analysis showed no difference in technique scores between the groups (p=0.46), but better ICS adherence among DPI users (p=0.001). In multivariable analysis, DPI use remained significantly associated with higher rates of adherence (OR 2.2; 95% CI 1.2 to 3.8) but not with inhaler technique (-0.2; 95% CI -0.5 to 0.1) after adjusting for potential confounders. CONCLUSIONS: Type of inhaler device appears to be associated with adherence to asthma controller medications. Prospective studies are needed to elucidate further the potential effect of the type of ICS delivery device on asthma self-management.
Authors: Gubena S Worku; Asfaw A Alemayehu; Woldearegay H Gebrehiwot; Hussen D Ali Journal: Allergy Asthma Clin Immunol Date: 2014-04-23 Impact factor: 3.406
Authors: Job F M van Boven; Joost J van Raaij; Ruben van der Galiën; Maarten J Postma; Thys van der Molen; P N Richard Dekhuijzen; Stefan Vegter Journal: NPJ Prim Care Respir Med Date: 2014-10-02 Impact factor: 2.871
Authors: Marc Miravitlles; Jéssica Montero-Caballero; Frank Richard; Salud Santos; Juan Luis Garcia-Rivero; Francisco Ortega; Xavier Ribera Journal: Int J Chron Obstruct Pulmon Dis Date: 2016-02-26
Authors: Josep Darbà; Gabriela Ramírez; Antoni Sicras; Pablo Francoli; Saku Torvinen; Rainel Sánchez-de la Rosa Journal: Int J Chron Obstruct Pulmon Dis Date: 2015-10-29
Authors: Henrik Svedsater; Loretta Jacques; Caroline Goldfrad; Eugene R Bleecker Journal: NPJ Prim Care Respir Med Date: 2014-06-26 Impact factor: 2.871