OBJECTIVE: The aim of this prospective clinical study was to evaluate the survival rates at 5 years of expanded platform implants placed in the anterior zone of the maxilla and immediately restored with single crowns.
MATERIALS AND METHODS: Implants incorporating the platform-switching concept were placed in fresh extraction sockets in the maxillary arch, with each patient receiving a provisional restoration immediately after implant placement. After 15 days, final screwed restorations were inserted. Mesial and distal bone heights were evaluated using digital radiography on the day following implant placement and at 1, 3, 6, 9, 12, 24, 36 months and 5 years. Primary stability was measured with resonance frequency analysis (RFA) using the Osstell Mentor device. Sixty-four implants were placed in 32 men and 32 women ranging in age between 29 and 60 (mean: 39.64 ± 5.16 years).
RESULTS: Mean mesial bone loss was 0.08 mm (SD 0.42). Mean distal bone loss was 0.14 mm (SD 0.56). Over the course of the 5 years, the mean RFA value was 72.5 ± 3.1 SD.
CONCLUSION: The platform-switched implants remained stable over the course of 5 years and had an overall survival rate of 97.1%.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2011        PMID: 21435008     DOI: 10.1111/j.1600-0501.2010.02130.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Laser micro-grooved, Arginine-Glycine-Apspartic acid (RGD) coated dental implants, a 5 years radiographic follow-up.

Authors:  Mohamed Ahmed Alkhodary
Journal:  Int J Health Sci (Qassim)       Date:  2014-10

2.  Platform switching: A panacea for bone loss??

Authors:  Manthan H Desai; Veena A Patil
Journal:  J Indian Soc Periodontol       Date:  2013-09

3.  Platform switching on wide-diameter external hex implants: a finite element analysis.

Authors:  Stefano Sivolella; Riccardo Guazzo; Eriberto Bressan; Mario Berengo; Edoardo Stellini
Journal:  J Clin Exp Dent       Date:  2013-04-01

4.  Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis.

Authors:  Wen-Tao Zhang; Kang-Jie Cheng; Fan Yang; Lin-Hong Wang; Yun-Feng Liu; Russell Wang; Yun-Fang Chen; Yu-de Ding
Journal:  BMC Oral Health       Date:  2022-09-30       Impact factor: 3.747

5.  Current results and trends in platform switching.

Authors:  Hadi Salimi; Omid Savabi; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2011-12

Review 6.  Marginal bone loss in relation to platform switching implant insertion depth: An update.

Authors:  Rocío Alonso-González; Amparo Aloy-Prósper; David Peñarrocha-Oltra; M A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2012-07-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.