Literature DB >> 21433068

32-channel RF coil optimized for brain and cervical spinal cord at 3 T.

J Cohen-Adad1, A Mareyam, B Keil, J R Polimeni, L L Wald.   

Abstract

Diffusion and functional magnetic resonance imaging of the spinal cord remain challenging due to the small cross-sectional size of the cord and susceptibility-related distortions. Although partially addressable through parallel imaging, few highly parallel array coils have been implemented for the cervical cord. Here, we developed a 32-channel coil that fully covers the brain and c-spine and characterized its performance in comparison with a commercially available head/neck/spine array. Image and temporal signal-to-noise ratio were, respectively, increased by 2× and 1.8× in the cervical cord. Averaged g-factors at 4× acceleration were lowered by 22% in the brain and by 39% in the spinal cord, enabling 1-mm isotropic R = 4 multi-echo magnetization prepared gradient echo of the full brain and c-spine in 3:20 min. Diffusion imaging of the cord at 0.6 × 0.6 × 5 mm(3) resolution and tractography of the full brain and c-spine at 1.7-mm isotropic resolution were feasible without noticeable distortion. Improvements of this nature potentially enhance numerous basic and clinical research studies focused on spinal and supraspinal regions.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21433068      PMCID: PMC3131444          DOI: 10.1002/mrm.22906

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Physiological noise in oxygenation-sensitive magnetic resonance imaging.

Authors:  G Krüger; G H Glover
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

3.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo.

Authors:  T G Reese; O Heid; R M Weisskoff; V J Wedeen
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

6.  Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI.

Authors:  Derek K Jones
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

7.  An MR transceive phased array designed for spinal cord imaging at 3 Tesla: preliminary investigations of spinal cord imaging at 3 T.

Authors:  David M Peterson; G Randy Duensing; Jim Caserta; Jeffrey R Fitzsimmons
Journal:  Invest Radiol       Date:  2003-07       Impact factor: 6.016

Review 8.  A brief review of parallel magnetic resonance imaging.

Authors:  Robin M Heidemann; Ozkan Ozsarlak; Paul M Parizel; Johan Michiels; Berthold Kiefer; Vladimir Jellus; Mathias Müller; Felix Breuer; Martin Blaimer; Mark A Griswold; Peter M Jakob
Journal:  Eur Radiol       Date:  2003-08-27       Impact factor: 5.315

9.  BOLD signal responses to controlled hypercapnia in human spinal cord.

Authors:  J Cohen-Adad; C J Gauthier; J C W Brooks; M Slessarev; J Han; J A Fisher; S Rossignol; R D Hoge
Journal:  Neuroimage       Date:  2010-01-11       Impact factor: 6.556

10.  MRI of the abnormal cervical spinal cord using 2D spoiled gradient echo multiecho sequence (MEDIC) with magnetization transfer saturation pulse. A T2* weighted feasibility study.

Authors:  P Held; U Dorenbeck; J Seitz; R Fründ; H Albrich
Journal:  J Neuroradiol       Date:  2003-03       Impact factor: 3.447

View more
  16 in total

Review 1.  Functional MRI of the Brainstem: Common Problems and their Solutions.

Authors:  F Beissner
Journal:  Clin Neuroradiol       Date:  2015-05-16       Impact factor: 3.649

2.  Interchangeable neck shape-specific coils for a clinically realizable anterior neck phased array system.

Authors:  Michael J Beck; Dennis L Parker; Bradley D Bolster; Seong-Eun Kim; J Scott McNally; Gerald S Treiman; J Rock Hadley
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

Review 3.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

4.  Subject-specific regional measures of water diffusion are associated with impairment in chronic spinal cord injury.

Authors:  Ann S Choe; Cristina L Sadowsky; Seth A Smith; Peter C M van Zijl; James J Pekar; Visar Belegu
Journal:  Neuroradiology       Date:  2017-06-08       Impact factor: 2.804

Review 5.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

Review 6.  The current state-of-the-art of spinal cord imaging: methods.

Authors:  P W Stroman; C Wheeler-Kingshott; M Bacon; J M Schwab; R Bosma; J Brooks; D Cadotte; T Carlstedt; O Ciccarelli; J Cohen-Adad; A Curt; N Evangelou; M G Fehlings; M Filippi; B J Kelley; S Kollias; A Mackay; C A Porro; S Smith; S M Strittmatter; P Summers; I Tracey
Journal:  Neuroimage       Date:  2013-05-14       Impact factor: 6.556

7.  Nineteen-channel receive array and four-channel transmit array coil for cervical spinal cord imaging at 7T.

Authors:  Wei Zhao; Julien Cohen-Adad; Jonathan R Polimeni; Boris Keil; Bastien Guerin; Kawin Setsompop; Peter Serano; Azma Mareyam; Philipp Hoecht; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2013-08-20       Impact factor: 4.668

8.  Improved in vivo diffusion tensor imaging of human cervical spinal cord.

Authors:  Junqian Xu; Joshua S Shimony; Eric C Klawiter; Abraham Z Snyder; Kathryn Trinkaus; Robert T Naismith; Tammie L S Benzinger; Anne H Cross; Sheng-Kwei Song
Journal:  Neuroimage       Date:  2012-11-21       Impact factor: 6.556

9.  Stimulus site and modality dependence of functional activity within the human spinal cord.

Authors:  Jonathan C W Brooks; Yazhuo Kong; Michael C Lee; Catherine E Warnaby; Vishvarani Wanigasekera; Mark Jenkinson; Irene Tracey
Journal:  J Neurosci       Date:  2012-05-02       Impact factor: 6.167

10.  Simultaneous Brain-Cervical Cord fMRI Reveals Intrinsic Spinal Cord Plasticity during Motor Sequence Learning.

Authors:  Shahabeddin Vahdat; Ovidiu Lungu; Julien Cohen-Adad; Veronique Marchand-Pauvert; Habib Benali; Julien Doyon
Journal:  PLoS Biol       Date:  2015-06-30       Impact factor: 8.029

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.