Stent-associated flow remodeling causes further occlusion of incompletely coiled aneurysms.

Matthew F Lawson1, William C Newman, Yueh-Yun Chi, J D Mocco, Brian L Hoh.   

Abstract

BACKGROUND: Incomplete coil occlusion is associated with increased risk of aneurysm recurrence. We hypothesize that intracranial stents can cause flow remodeling, which promotes further occlusion of an incompletely coiled aneurysm.
OBJECTIVE: To study our hypothesis by comparing the follow-up angiographic outcomes of stented and nonstented incompletely coiled aneurysms.
METHODS: From January 2006 through December 2009, the senior author performed 324 initial coilings of previously untreated aneurysms, 145 of which were Raymond classification 2 and 3. Follow-up angiographic studies were available for 109 of these aneurysms (75%). Angiographic outcomes for stented vs nonstented incompletely coiled aneurysms were compared. A multivariate analysis was performed to identify factors related to the progression of occlusion at follow-up, with adjustment for aneurysm location, size, neck size, Hunt-Hess grade, stent use, initial Raymond score, packing density, age, sex, and medical comorbidities.
RESULTS: Of the 109 aneurysms, 37 were stented and 72 were not stented. With a median follow-up time of 15.4 months, 33 stented aneurysms (89%) progressed to complete occlusion compared with 29 nonstented aneurysms (40%). Recanalization rates were lower in the stented group (8.1%) compared with the nonstented group (37.5%; P < .001). On multivariate analysis, stent use (odds ratio, 18.5; 95% confidence interval, 4.3-76.9) and packing density (odds ratio, 1.093; 95% confidence interval, 1.021-1.170) were significant predictors of the progression of occlusion. Aneurysm size was negatively correlated with the progression of occlusion (odds ratio, 0.844; 95% confidence interval, 0.724-0.983).
CONCLUSION: Stent-assisted coiling causes progression of occlusion, possibly by a flow remodeling effect. The odds of progression of occlusion of stent-coiled aneurysms were 18.5 times that of nonstented aneurysms.

Entities:  

Mesh:

Year:  2011        PMID: 21430583     DOI: 10.1227/NEU.0b013e3182181c2b

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  39 in total

Review 1.  Review of 2 decades of aneurysm-recurrence literature, part 1: reducing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

2.  Staged treatment of a blood blister-like aneurysm with stent-assisted coiling followed by flow diverter in-stent insertion. A case report.

Authors:  C Princiotta; M Dall'olio; L Cirillo; M Leonardi
Journal:  Interv Neuroradiol       Date:  2011-10-17       Impact factor: 1.610

3.  Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients.

Authors:  Jacques Sedat; Yves Chau; Jean Gaudart; Marina Sachet; Stephanie Beuil; Michel Lonjon
Journal:  Neuroradiology       Date:  2017-12-23       Impact factor: 2.804

4.  Treatment of acutely ruptured wide-necked intracranial aneurysms using self-expanding stent.

Authors:  Hui Li; Jinqun Guan; Jianfeng Liu; Kai Hou; Di Zhao; Guobiao Wu; Lifeng Xu; Linlin Liu
Journal:  Int J Clin Exp Med       Date:  2015-01-15

5.  Modification of cerebral vascular anatomy induced by Leo stent placement depending on the site of stenting: A series of 102 cases.

Authors:  Y Chau; L Mondot; M Sachet; J Gaudart; D Fontaine; M Lonjon; J Sédat
Journal:  Interv Neuroradiol       Date:  2016-08-02       Impact factor: 1.610

6.  Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

Authors:  Jian Liu; Linkai Jing; Chao Wang; Nikhil Paliwal; Shengzhang Wang; Ying Zhang; Jianping Xiang; Adnan H Siddiqui; Hui Meng; Xinjian Yang
Journal:  J Neurointerv Surg       Date:  2015-11-26       Impact factor: 5.836

7.  Extended monitoring of coiled aneurysms completely occluded at 6-month follow-up: late recanalization rate and related risk factors.

Authors:  Jin Pyeong Jeon; Young Dae Cho; Jong Kook Rhim; Dong Hyun Yoo; Hyun-Seung Kang; Jeong Eun Kim; Won-Sang Cho; Moon Hee Han
Journal:  Eur Radiol       Date:  2016-01-08       Impact factor: 5.315

8.  Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.

Authors:  Chao Wang; Zhongbin Tian; Jian Liu; Linkai Jing; Nikhil Paliwal; Shengzhang Wang; Ying Zhang; Jianping Xiang; Adnan H Siddiqui; Hui Meng; Xinjian Yang
Journal:  Acta Neurochir (Wien)       Date:  2016-01-08       Impact factor: 2.216

9.  Neuroform stent-assisted treatment of intracranial aneurysms: long-term follow-up study of aneurysm recurrence and in-stent stenosis rates.

Authors:  Zsolt Kulcsár; Sophia L Göricke; Elke R Gizewski; Marc Schlamann; Ulrich Sure; I Erol Sandalcioglu; Susanne Ladd; Petra Mummel; Oliver Kastrup; Michael Forsting; Isabel Wanke
Journal:  Neuroradiology       Date:  2013-01-29       Impact factor: 2.804

10.  Stent-assisted embolization of recurrent or residual intracranial aneurysms.

Authors:  Olli I Tähtinen; Hannu I Manninen; Ritva L Vanninen; Riitta Rautio; Arto Haapanen; Janne Seppänen; Tero Niskakangas; Jaakko Rinne; Leo Keski-Nisula
Journal:  Neuroradiology       Date:  2013-07-17       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.