Keo Sik Kim1, Jeong Hwan Seo, Sang Hun Ryu, Min Ho Kim, Chul Gyu Song.
Abstract
Bowel sound (BS) signals can be used clinically as useful indicators of bowel motility. In this study, we devised a modified iterative kurtosis-based detector algorithm, in order to enhance the de-noising performance of BS signals, and an estimation algorithm of bowel motility based on the regression modeling of the jitter and shimmer of BS signals obtained by auscultation. The correlation coefficient, coefficient of determination and errors between the colon transit times measured by a conventional radiograph and the corresponding values estimated by our method were 0.987, 0.974 and 3.5 ± 3.3h, respectively. These results demonstrated that our method could be used as a complementary tool for the non-invasive diagnosis and monitoring of bowel motility, instead of conventional radiography. Crown Copyright ÂEntities:
Mesh:
Year: 2011 PMID: 21429614 DOI: 10.1016/j.cmpb.2011.02.014
Source DB: PubMed Journal: Comput Methods Programs Biomed ISSN: 0169-2607 Impact factor: 5.428