Literature DB >> 21424151

Image quality in obese patients undergoing 256-row computed tomography coronary angiography.

Orit Lesman Segev1, Tamar Gaspar, David A Halon, Nathan Peled, Liran Domachevsky, Basil S Lewis, Ronen Rubinshtein.   

Abstract

To evaluate, objectively and subjectively, the feasibility of 256-row computed tomography coronary angiography (CTCA) in obese patients. 256-row CTCA was performed in 68 symptomatic patients (age 61 ± 10 years, 37 females), 39 obese (body mass index-BMI > 30 kg/m(2)) and 29 non-obese. Retrospective analysis was performed by two observers who assessed the image quality of each coronary segment using a 4-point subjective scale (1 excellent to 4 non-diagnostic), and another blinded observer measured objective image parameters. BMI in the obese group was 35 ± 5 (32-65) Kg/m(2), and 24 ± 3 (16-29) Kg/m(2) in the non-obese (P = 0.004). Average subjective image quality was similar in obese (1.41 ± 0.40) and non-obese (1.34 ± 0.40) patients, P = 0.17. Proportion of coronary artery segments with non-diagnostic image quality was low in both groups (0.7% in obese and 0.2% in non-obese, P = 0.31). Signal to noise and contrast to noise ratios were not significantly lower in obese than in non-obese patients (9.4 ± 3 vs. 12 ± 2.5, P = 0.16 and 11.1 ± 3.8 vs. 13.7 ± 2.9, P = 0.07 respectively). However, dose length product (1167 ± 567 vs. 827 ± 375 mGy × cm, P = 0.014) and image noise (44 ± 13 vs. 35 ± 5 HU, P < 0.001) were higher in the obese patient group. Image quality was preserved in obese patients undergoing 256-row CTCA at the cost of increased radiation exposure and image noise.

Entities:  

Mesh:

Year:  2011        PMID: 21424151     DOI: 10.1007/s10554-011-9848-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

1.  Relation between obesity and severity of coronary artery disease in patients undergoing coronary angiography.

Authors:  Ronen Rubinshtein; David A Halon; Ronen Jaffe; Johnny Shahla; Basil S Lewis
Journal:  Am J Cardiol       Date:  2006-03-13       Impact factor: 2.778

2.  Effect of increasing body mass index on image quality and positive predictive value of 100-kV coronary computed tomographic angiography.

Authors:  John S Ho; Carolyn E Barlow; Dale B Reinhardt; Wendy A Wade; John J Cannaday
Journal:  Am J Cardiol       Date:  2010-10-15       Impact factor: 2.778

3.  Effect of patient obesity on the accuracy of thallium-201 myocardial perfusion imaging.

Authors:  C L Hansen; S Woodhouse; M Kramer
Journal:  Am J Cardiol       Date:  2000-03-15       Impact factor: 2.778

Review 4.  CT coronary angiography: 256-slice and 320-detector row scanners.

Authors:  Edward M Hsiao; Frank J Rybicki; Michael Steigner
Journal:  Curr Cardiol Rep       Date:  2010-01       Impact factor: 2.931

Review 5.  Obesity and cardiovascular disease: pathophysiology, evaluation, and effect of weight loss: an update of the 1997 American Heart Association Scientific Statement on Obesity and Heart Disease from the Obesity Committee of the Council on Nutrition, Physical Activity, and Metabolism.

Authors:  Paul Poirier; Thomas D Giles; George A Bray; Yuling Hong; Judith S Stern; F Xavier Pi-Sunyer; Robert H Eckel
Journal:  Circulation       Date:  2005-12-27       Impact factor: 29.690

Review 6.  64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis.

Authors:  Jawdat Abdulla; Steen Z Abildstrom; Ole Gotzsche; Erik Christensen; Lars Kober; Christian Torp-Pedersen
Journal:  Eur Heart J       Date:  2007-11-02       Impact factor: 29.983

7.  Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography.

Authors:  Michael L Steigner; Hansel J Otero; Tianxi Cai; Dimitrios Mitsouras; Leelakrishna Nallamshetty; Amanda G Whitmore; Hale Ersoy; Noah A Levit; Marcelo F Di Carli; Frank J Rybicki
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-29       Impact factor: 2.357

8.  Randomized comparison of 64-slice single- and dual-source computed tomography coronary angiography for the detection of coronary artery disease.

Authors:  Stephan Achenbach; Ulrike Ropers; Axel Kuettner; Katharina Anders; Tobias Pflederer; Sei Komatsu; Werner Bautz; Werner G Daniel; Dieter Ropers
Journal:  JACC Cardiovasc Imaging       Date:  2008-03

9.  Impact of body mass index on in-hospital outcomes following percutaneous coronary intervention (report from the New York State Angioplasty Registry).

Authors:  Robert M Minutello; Eric T Chou; Mun K Hong; Geoffrey Bergman; Manish Parikh; Frank Iacovone; S Chiu Wong
Journal:  Am J Cardiol       Date:  2004-05-15       Impact factor: 2.778

10.  Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters.

Authors:  Hatem Alkadhi; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Stephan Baumüller; André Plass; Michele Genoni; Borut Marincek; Sebastian Leschka
Journal:  Eur J Radiol       Date:  2008-10-30       Impact factor: 3.528

View more
  5 in total

1.  The associated factors for radiation dose variation in cardiac CT angiography.

Authors:  Ali B Alhailiy; Ernest U Ekpo; Peter L Kench; Elaine A Ryan; Patrick C Brennan; Mark McEntee
Journal:  Br J Radiol       Date:  2019-01-31       Impact factor: 3.039

2.  Does epicardial adipose tissue volume provide information about the presence and localization of coronary artery disease?

Authors:  Neşat Çullu; Mecit Kantarcı; Yeşim Kızrak; Berhan Pirimoğlu; Ümmügülsüm Bayraktutan; Hayri Oğul; Leyla Karaca
Journal:  Anatol J Cardiol       Date:  2014-04-16       Impact factor: 1.596

3.  Pixel-Level Deep Segmentation: Artificial Intelligence Quantifies Muscle on Computed Tomography for Body Morphometric Analysis.

Authors:  Hyunkwang Lee; Fabian M Troschel; Shahein Tajmir; Georg Fuchs; Julia Mario; Florian J Fintelmann; Synho Do
Journal:  J Digit Imaging       Date:  2017-08       Impact factor: 4.056

4.  The superiority of 256-slice spiral computed tomography angiography for preoperative evaluation of surrounding arteries in patients with gastric cancer.

Authors:  Deqing Wu; Linyong Zhao; Ying Liu; Junjiang Wang; Weixian Hu; Xingyu Feng; Zejian Lv; Yong Li; Xueqing Yao
Journal:  Onco Targets Ther       Date:  2017-02-16       Impact factor: 4.147

5.  Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images.

Authors:  David C Rotzinger; Salim A Si-Mohamed; Jérôme Yerly; Sara Boccalini; Fabio Becce; Loïc Boussel; Reto A Meuli; Salah D Qanadli; Philippe C Douek
Journal:  Eur Radiol       Date:  2021-03-19       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.