Literature DB >> 21423058

Oblique lumbar interbody fixation: a biomechanical study in human spines.

Selvon St Clair1, Juay Seng Tan, Isador Lieberman.   

Abstract

STUDY
DESIGN: In vitro spine biomechanics.
OBJECTIVE: To determine the biomechanical properties of oblique lumbar interbody fixation (OLIF) in human cadaveric spines. SUMMARY OF BACKGROUND DATA: OLIF has been used for stabilization of degenerative spondylolisthesis at the lumbosacral junction. Biomechanical properties and mode of failure of OLIF as a standalone device for motion segments without sagittal deformity has not yet been investigated. We hypothesize that the biomechanical properties of OLIF will be comparable with the contemporary standard of pedicle screw (PS) fixation.
METHOD: Randomly matched motion segments from L1 to L5 were allocated into 2 groups: (A) OLIF (group 1, n=5) or (B) PS (group 2, n=5). The intact and instrumented motion segments with and without anterior interbody graft were first tested under a combination of 200N axial compression and 5 Nm bending moments in flexion-extension and in lateral bending. Range of motion (ROM) and neutral zone were determined and compared between intact, OLIF and PS. A final load to failure test was carried out for each motion segment in either flexion or extension. RESULT: OLIF resulted in reduction of flexion-extension ROM to 36%±14% of intact whereas PS resulted in reduction to 27%±22% of intact. The reduction of lateral bending ROM were 32%±13% and 32%±24% of intact with OLIF and PS. There were no significant difference in ROM between OLIF and PS (P=0.39). The mean failure loads with OLIF and PS in flexion were 1284 and 1158N, and in extension were 1879 and 1934N, respectively. Failure occurred at the ventral screw bone interface without pedicle fracture.
CONCLUSIONS: These results indicate that stiffness and load to failure of the OLIF is comparable with PS fixation. OLIF failure occurred ventrally through the anterior cortical rim without concomitant pedicle fracture.

Entities:  

Mesh:

Year:  2012        PMID: 21423058     DOI: 10.1097/BSD.0b013e318211fc6b

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  11 in total

1.  Percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion: a radiological and cadaveric study.

Authors:  Ai-Min Wu; Wen-Fei Ni; Zhen-Xuan Shao; Xiang-Jie Kong; Nai-Feng Tian; Yi-Xing Huang; Zhong-Ke Lin; Hua-Zi Xu; Yong-Long Chi
Journal:  Eur Spine J       Date:  2014-11-13       Impact factor: 3.134

2.  Letter to the Editor: The Oblique Anterolateral Approach to the Lumbar Spine Provides Access to the Lumbar Spine With Few Early Complications.

Authors:  Shanming Chen; Lin Cai
Journal:  Clin Orthop Relat Res       Date:  2016-11-07       Impact factor: 4.176

3.  Importance of the epiphyseal ring in OLIF stand-alone surgery: a biomechanical study on cadaveric spines.

Authors:  Xuyang Zhang; Hao Wu; Yilei Chen; Junhui Liu; Jian Chen; Teng Zhang; ZhaoFeng Zhou; Shunwu Fan; Patricia Dolan; Michael Anthony Adams; Fengdong Zhao
Journal:  Eur Spine J       Date:  2020-11-23       Impact factor: 3.134

4.  Biomechanical properties of posterior transpedicular-transdiscal oblique lumbar screw fixation with novel trapezoidal lateral interbody spacer: an in vitro human cadaveric model.

Authors:  Ai-Min Wu; Jonathan A Harris; John C Hao; Sean M Jenkins; Yong-Long Chi; Brandon S Bucklen
Journal:  Eur Spine J       Date:  2017-04-06       Impact factor: 3.134

5.  Effect of pedicle-screw rod fixation on oblique lumbar interbody fusion in patients with osteoporosis: a retrospective cohort study.

Authors:  Kaiwen Cai; Kefeng Luo; Jinjin Zhu; Kai Zhang; Shengkai Yu; Yi Ye; Guoqiang Jiang
Journal:  J Orthop Surg Res       Date:  2021-07-03       Impact factor: 2.359

6.  The current testing protocols for biomechanical evaluation of lumbar spinal implants in laboratory setting: a review of the literature.

Authors:  Sabrina A Gonzalez-Blohm; James J Doulgeris; William E Lee; Thomas M Shea; Kamran Aghayev; Frank D Vrionis
Journal:  Biomed Res Int       Date:  2015-02-15       Impact factor: 3.411

7.  Effect of Cage in Radiological Differences between Direct and Oblique Lateral Interbody Fusion Techniques.

Authors:  Myeong Jin Ko; Seung Won Park; Young Baeg Kim
Journal:  J Korean Neurosurg Soc       Date:  2019-05-08

8.  Oblique Lateral Interbody Fusion with Anterolateral Screw Fixation Is as Effective as with Posterior Percutaneous Pedicle Screw Fixation in Treating Single-Segment Mild Degenerative Lumbar Diseases.

Authors:  Yunshan Guo; Xiaodong Wang; Yibing Li; Kuo Jiang; Bo Chen; Jing An; Dingjun Hao; Huimin Hu
Journal:  Med Sci Monit       Date:  2022-01-08

Review 9.  Evidence-based support for S1 transpedicular screw entry point modification.

Authors:  Lukasz Kubaszewski; Andrzej Nowakowski; Jacek Kaczmarczyk
Journal:  J Orthop Surg Res       Date:  2014-04-03       Impact factor: 2.359

10.  Biomechanical properties of novel transpedicular transdiscal screw fixation with interbody arthrodesis technique in lumbar spine: A finite element study.

Authors:  Qing-Bo Lv; Xiang Gao; Xiang-Xiang Pan; Hai-Ming Jin; Xiao-Ting Lou; Shu-Min Li; Ying-Zhao Yan; Cong-Cong Wu; Yan Lin; Wen-Fei Ni; Xiang-Yang Wang; Ai-Min Wu
Journal:  J Orthop Translat       Date:  2018-09-10       Impact factor: 5.191

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.