Abstract

PURPOSE: To assess the degree of capsular bag opacification in human cadaver eyes with silicone intraocular lenses (IOLs), specifically comparing the differences between round-edged IOLs and modern square-edged IOLs.
SETTING: John A. Moran Eye Center, University of Utah, USA.
DESIGN: Experimental study.
METHODS: The eyes were immersed in 10% formalin on enucleation. They had anterior segment scanning with a very-high-frequency ultrasound (Artemis). After the eyes were sectioned at the equator, gross examination of the anterior segment was performed from the posterior aspect to assess the degree of capsular bag opacification, coverage of the IOL edge by the anterior capsule, and IOL fixation. Selected eyes also had histopathologic examination.
RESULTS: Eighty-seven eyes with a 3-piece round-edged IOL, 43 with a 3-piece square-edged IOL, 26 with a 1-piece plate IOL, and 1 with an accommodating IOL design were included in the analyses of capsular bag opacification. Comparison between 3-piece round-edged IOLs and square-edged IOLs showed statistically significant differences in central posterior capsule opacification (PCO) (P=.0001687) and peripheral PCO (P<.0001). In eyes with square-edged IOLs, PCO had a tendency to start in areas without capsulorhexis coverage of the optic. Twenty-one of 26 eyes with a silicone plate IOL had a neodymium:YAG posterior capsulotomy for dense PCO.
CONCLUSIONS: This first study using pseudophakic human cadaver eyes that includes a significant number of modern 3-piece silicone IOLs with square optic edges confirmed the role of this design in the prevention of PCO. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21420600     DOI: 10.1016/j.jcrs.2010.10.058

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Pathologic assessment of complications with asymmetric or sulcus fixation of square-edged hydrophobic acrylic intraocular lenses.

Authors:  Kevin R Kirk; Liliana Werner; Ryan Jaber; Susan Strenk; Lawrence Strenk; Nick Mamalis
Journal:  Ophthalmology       Date:  2012-03-15       Impact factor: 12.079

2.  Uveitis-glaucoma-hyphema syndrome associated with an in-the-bag square-edge intraocular lens.

Authors:  Jin Yang; Xiaodi Qiu; Lei Cai; Qi Fan; Anjian Wang; Kang Zhang; Yi Lu
Journal:  Precis Clin Med       Date:  2019-11-29

3.  Pathologic comparison of asymmetric or sulcus fixation of 3-piece intraocular lenses with square versus round anterior optic edges.

Authors:  Andrew Ollerton; Liliana Werner; Susan Strenk; Lawrence Strenk; Lisa Leishman; Zachary Bodnar; Kevin R Kirk; Jennifer Michelson; Nick Mamalis
Journal:  Ophthalmology       Date:  2013-04-16       Impact factor: 12.079

4.  Long-term efficiency of cataract surgery with hydrophilic acrylic Ioflex intraocular lens.

Authors:  Priscilla A Jorge; Camila Ribeiro Koch; Delano Jorge; Newton Kara-Junior
Journal:  Clinics (Sao Paulo)       Date:  2017-10       Impact factor: 2.365

5.  Time Course of Lens Epithelial Cell Behavior in Rabbit Eyes following Lens Extraction and Implantation of Intraocular Lens.

Authors:  Daijiro Kurosaka; Toshiyasu Imaizumi; Junya Kizawa
Journal:  J Ophthalmol       Date:  2021-01-16       Impact factor: 1.909

Review 6.  Recent Advances of Intraocular Lens Materials and Surface Modification in Cataract Surgery.

Authors:  Chenqi Luo; Hanle Wang; Xinyi Chen; Jingjie Xu; Houfa Yin; Ke Yao
Journal:  Front Bioeng Biotechnol       Date:  2022-06-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.