Literature DB >> 21418360

Silver alloy vs. uncoated urinary catheters: a systematic review of the literature.

Michelle Beattie1, Julie Taylor.   

Abstract

AIMS AND
OBJECTIVES: This systematic review aimed to determine whether there was enough evidence to conclude that silver-alloy urinary catheters reduce catheter-associated urinary tract infections compared with silicone or latex urinary catheters in adult inpatients.
BACKGROUND: Previous systematic reviews into the effectiveness of silver-coated urinary catheters have offered limited opportunity to transfer their findings into practice. These studies have been on North American products only, of generally poor quality, or several years since their completion (Brosnahan J, Jull A & Tracy C 2004, Cochrane Database Systematic Reviews, Issue 1, Art. No.: CD004013). Design.  A systematic review of the literature was deemed the most appropriate research method to apply as there had already been several studies (Saint S, Veenstra DL, Sullivan SD, Chenoweth C & Fendrick AM 2000, Archives of International Medicine, 160, 2670-2675; Lai KK & Fontecchio SA 2002, American Journal of Infection Control, 30, 221-225; Schaeffer AJ 2005, The Journal of Urology, 173, 845-846) relating to the subject in question, although there were some queries regarding their methodological rigour.
METHODS: Randomised control trials, systematic reviews and meta-analyses were identified by searching relevant databases. Relevant papers were judged against predefined inclusion and exclusion criteria. Ten per cent of papers were assessed by a second reviewer. Following the application of a numerical filtering tool, six papers were rejected and eleven papers were retained.
RESULTS: Of the 11 papers retained, there were eight studies, as some studies published more than one paper. The integrated results did present a consistent pattern favourable towards the efficacy of silver-alloy urinary catheters to reduce catheter-associated urinary tract infection.
CONCLUSION: The collective evidence divulged an emerging pattern favouring the efficacy of silver-alloy urinary catheters to reduce catheter-associated urinary tract infection. Owing to the poor quality of some individual studies included in other systematic reviews and the inability to carry out meta-analysis because of significant heterogeneity, definitive conclusions cannot be drawn from the study. RELEVANCE TO CLINICAL PRACTICE: Given the significant prevalence of catheter-associated urinary tract infection, early indications of improved infection rate outcomes using silver-alloy urinary catheters should not be dismissed.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21418360     DOI: 10.1111/j.1365-2702.2010.03561.x

Source DB:  PubMed          Journal:  J Clin Nurs        ISSN: 0962-1067            Impact factor:   3.036


  11 in total

Review 1.  The emerging threat of multidrug-resistant Gram-negative bacteria in urology.

Authors:  Hosam M Zowawi; Patrick N A Harris; Matthew J Roberts; Paul A Tambyah; Mark A Schembri; M Diletta Pezzani; Deborah A Williamson; David L Paterson
Journal:  Nat Rev Urol       Date:  2015-09-01       Impact factor: 14.432

2.  epic3: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England.

Authors:  H P Loveday; J A Wilson; R J Pratt; M Golsorkhi; A Tingle; A Bak; J Browne; J Prieto; M Wilcox
Journal:  J Hosp Infect       Date:  2014-01       Impact factor: 3.926

3.  Silver(I), mercury(II), cadmium(II), and zinc(II) target exposed enzymic iron-sulfur clusters when they toxify Escherichia coli.

Authors:  Fang Fang Xu; James A Imlay
Journal:  Appl Environ Microbiol       Date:  2012-02-17       Impact factor: 4.792

Review 4.  Scaffold-based anti-infection strategies in bone repair.

Authors:  Christopher T Johnson; Andrés J García
Journal:  Ann Biomed Eng       Date:  2014-12-05       Impact factor: 3.934

Review 5.  How to Prevent Catheter-Associated Urinary Tract Infections: A Reappraisal of Vico's Theory-Is History Repeating Itself?

Authors:  Stefania Musco; Alessandro Giammò; Francesco Savoca; Luca Gemma; Paolo Geretto; Marco Soligo; Emilio Sacco; Giulio Del Popolo; Vincenzo Li Marzi
Journal:  J Clin Med       Date:  2022-06-14       Impact factor: 4.964

6.  Economic evaluation of quality improvement interventions to prevent catheter-associated urinary tract infections in the hospital setting: a systematic review.

Authors:  Sara G McCleskey; Lili Shek; Jonathan Grein; Hiroshi Gotanda; Laura Anderson; Paul G Shekelle; Emmett Keeler; Sally Morton; Teryl K Nuckols
Journal:  BMJ Qual Saf       Date:  2021-11-25       Impact factor: 7.418

Review 7.  PVP-coated, negatively charged silver nanoparticles: A multi-center study of their physicochemical characteristics, cell culture and in vivo experiments.

Authors:  Sebastian Ahlberg; Alexandra Antonopulos; Jörg Diendorf; Ralf Dringen; Matthias Epple; Rebekka Flöck; Wolfgang Goedecke; Christina Graf; Nadine Haberl; Jens Helmlinger; Fabian Herzog; Frederike Heuer; Stephanie Hirn; Christian Johannes; Stefanie Kittler; Manfred Köller; Katrin Korn; Wolfgang G Kreyling; Fritz Krombach; Jürgen Lademann; Kateryna Loza; Eva M Luther; Marcelina Malissek; Martina C Meinke; Daniel Nordmeyer; Anne Pailliart; Jörg Raabe; Fiorenza Rancan; Barbara Rothen-Rutishauser; Eckart Rühl; Carsten Schleh; Andreas Seibel; Christina Sengstock; Lennart Treuel; Annika Vogt; Katrin Weber; Reinhard Zellner
Journal:  Beilstein J Nanotechnol       Date:  2014-11-03       Impact factor: 3.649

8.  Improved ex vivo blood compatibility of central venous catheter with noble metal alloy coating.

Authors:  Manijeh Vafa Homann; Dorota Johansson; Håkan Wallen; Javier Sanchez
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-07-06       Impact factor: 3.368

Review 9.  Ureteral stent technology: Drug-eluting stents and stent coatings.

Authors:  Luo Yang; Samantha Whiteside; Peter A Cadieux; John D Denstedt
Journal:  Asian J Urol       Date:  2015-09-21

10.  Restriction of in vivo infection by antifouling coating on urinary catheter with controllable and sustained silver release: a proof of concept study.

Authors:  Kedar Diwakar Mandakhalikar; Rong Wang; Juwita N Rahmat; Edmund Chiong; Koon Gee Neoh; Paul A Tambyah
Journal:  BMC Infect Dis       Date:  2018-08-06       Impact factor: 3.090

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.