Literature DB >> 21418125

Self-expanding metal stent insertion for inoperable esophageal carcinoma in Belfast: an audit of outcomes and literature review.

R T Gray1, M E O'Donnell, R D Scott, J A McGuigan, I Mainie.   

Abstract

Successful palliation of dysphagia in patients with inoperable esophageal carcinoma has a major effect on quality of life. Self-expanding metal stents (SEMS) are currently recommended for rapid symptomatic relief when life expectancy is less than 3 months. We assessed complication and reintervention rates along with survival outcomes in patients with inoperable esophageal carcinoma undergoing stent insertion. A retrospective audit was performed from April 2007 to June 2009 for all inoperable primary esophageal carcinoma patients who had an esophageal stent inserted for dysphagia. Case notes were reviewed for clinical, pathological, stent and complication details, while ICD-10 causes of death were obtained from the Department of Health and Social Services, Northern Ireland. Fifty-six stents were inserted into 53 patients (66.0% male, mean age of 70 years). Inoperability was defined by metastatic spread (n= 34, 64.2%), locally advanced disease (n= 7, 13.2%), and severe medical comorbidities (n= 12, 22.6%). The median time from diagnosis to stent insertion was 109 (interquartile range [IQR] 43-187) days. Fifty stents (94.3%) were successfully deployed, while three patients (5.7%) required an additional stent as the primary stent had not bridged the tumor (proximal deployment = 2, suboptimal stent length = 1). Post-SEMS dysphagia scores were significantly better than pre-SEMS scores (2.90 vs. 1.54, P < 0.001). There were 27 complications identified in 23 (43.4%) patients (major complications = 9, minor complications = 14). Twelve patients (22.6%) required additional endoscopic procedures. The 30-day mortality rate was 11.3% (n= 6). Only one patient (1.9%) remains alive with a cumulative median survival rate of 84 (IQR 38-156) days. Esophageal stent insertion in this group of patients still presents a clinical challenge, with complication and endoscopic reintervention rates of 43.4 and 22.6%, respectively. Our results are comparable with previously published series, and as a palliative modality stent insertion remains appropriate when expected survival is less than 3 months. A range of SEMS is currently available with broadly similar efficacy and safety profiles. Data regarding the newly available fully covered SEMS suggest that they should be avoided.
© 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

Entities:  

Mesh:

Year:  2011        PMID: 21418125     DOI: 10.1111/j.1442-2050.2011.01188.x

Source DB:  PubMed          Journal:  Dis Esophagus        ISSN: 1120-8694            Impact factor:   3.429


  4 in total

1.  Argon plasma coagulation compared with stent placement in the palliative treatment of inoperable oesophageal cancer.

Authors:  Dimitrios E Sigounas; Christoforos Krystallis; Graeme Couper; Simon Paterson-Brown; Athina Tatsioni; John N Plevris
Journal:  United European Gastroenterol J       Date:  2016-06-23       Impact factor: 4.623

2.  Tracheo-oesophageal fistula after palliative treatment of oesophageal cancer.

Authors:  Peter W Hamer; Ewen A Griffiths; Peter G Devitt
Journal:  J Gastrointest Oncol       Date:  2015-10

3.  A decade of day-case endoscopically guided stent placement in malignant oesophagogastric strictures.

Authors:  L M Almond; K Patel; L Keast; J Hodson; R Nijjar; P G Wilson; M Richardson; R Singhal
Journal:  Surg Endosc       Date:  2016-09-09       Impact factor: 4.584

4.  Outcomes following interventions to sustain body weight in esophageal cancer patients starting preoperative therapy: a retrospective cohort study.

Authors:  Jeffrey B Velotta; Jennifer R Dusendang; Hyunjee Kwak; Michelle Huyser; Ashish Patel; Simon K Ashiku; Lisa J Herrinton
Journal:  J Thorac Dis       Date:  2021-09       Impact factor: 2.895

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.