Literature DB >> 21417841

Measurement of the aortic annulus size by real-time three-dimensional transesophageal echocardiography.

Rolf Alexander Jánosi1, Philipp Kahlert, Björn Plicht, Daniel Wendt, Holger Eggebrecht, Raimund Erbel, Thomas Buck.   

Abstract

We sought to determine the level of agreement and the reproducibility of two-dimensional (2D) transthoracic (2D-TTE), 2D transesophageal (2D-TEE) and real-time three-dimensional (3D) transesophageal echocardiography (RT3D-TEE) for measurement of aortic annulus size in patients referred for transcatheter aortic valve implantation (TAVI). Accurate preoperative assessment of the dimensions of the aortic annulus is critical for patient selection and successful implantation in those undergoing TAVI for severe aortic stenosis (AS). Annulus size was measured using 2D-TTE, 2D-TEE and RT3D-TEE in 105 patients with severe AS referred for TAVI. Agreement between echocardiographic methods and interobserver variability was assessed using the Bland-Altman method and regression analysis, respectively. The mean aortic annuli were 21,7 ± 3 mm measured with 2D-TTE, 22,6 ± 2,8 mm with 2D-TEE and 22,3 ± 2,9 mm with RT3D-TEE. The results showed a small but significant mean difference and a strong correlation between the three measurement techniques (2D-TTE vs. 2D-TEE mean difference 0,84 ± 1,85 mm, r = 0,8, p < 0,0001; 2D-TEE vs. 3D-TEE 0,27 ± 1,14 mm, r = 0,91, p < 0,02; 2D-TTE vs. 3D-TEE 0,58 ± 2,21 mm, r = 0,72, p = 0,02); however, differences between measurements amounted up to 6,1 mm. Interobserver variability for 2D-TTE and 2D-TEE was substantially higher compared with RT3D-TEE. We found significant differences in the dimensions of the aortic annulus measured by 2D-TTE, 2D-TEE and RT3D-TEE. Thus, in patients referred for TAVI, the echocardiographic method used may have an impact on TAVI strategy.

Entities:  

Mesh:

Year:  2011        PMID: 21417841     DOI: 10.3109/13645706.2011.557385

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  8 in total

Review 1.  Current developments in transcatheter aortic valve implantation techniques.

Authors:  M Thielmann; P Kahlert; T Konorza; R Erbel; H Jakob; D Wendt
Journal:  Herz       Date:  2011-12       Impact factor: 1.443

Review 2.  Transcatheter Aortic Valve Replacement: Comprehensive Review and Present Status.

Authors:  Sameer Arora; Jacob A Misenheimer; Radhakrishnan Ramaraj
Journal:  Tex Heart Inst J       Date:  2017-02-01

Review 3.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 4.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

Review 5.  [Echocardiography during transcatheter interventions. New developments].

Authors:  J Balzer
Journal:  Herz       Date:  2013-02       Impact factor: 1.443

Review 6.  Quantitative Analysis of Aortic Valve Stenosis and Aortic Root Dimensions by Three-Dimensional Echocardiography in Patients Scheduled for Transcutaneous Aortic Valve Implantation.

Authors:  Rolf Alexander Jánosi; Björn Plicht; Philipp Kahlert; Mareike Eißmann; Daniel Wendt; Heinz Jakob; Raimund Erbel; Thomas Buck
Journal:  Curr Cardiovasc Imaging Rep       Date:  2014

7.  Transesophageal echocardiography measurements of aortic annulus diameter using biplane mode in patients undergoing transcatheter aortic valve implantation.

Authors:  Kambiz Shahgaldi; Cristina da Silva; Magnus Bäck; Andreas Rück; Aristomenis Manouras; Anders Sahlén
Journal:  Cardiovasc Ultrasound       Date:  2013-01-30       Impact factor: 2.062

Review 8.  A systematic approach to 3D echocardiographic assessment of the aortic root.

Authors:  Andreas Hagendorff; Stephan Stoebe; Bhupendar Tayal
Journal:  Glob Cardiol Sci Pract       Date:  2018-06-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.