| Literature DB >> 21416534 |
Richard J A Goodwin1, Andrew R Pitt, David Harrison, Stefan K Weidt, Pat R R Langridge-Smith, Michael P Barrett, C Logan Mackay.
Abstract
Mass spectrometry imaging (MSI) is a powerful tool in metabolomics and proteomics for the spatial localization and identification of pharmaceuticals, metabolites, lipids, peptides and proteins in biological tissues. However, sample preparation remains a crucial variable in obtaining the most accurate distributions. Common washing steps used to remove salts, and solvent-based matrix application, allow analyte spreading to occur. Solvent-free matrix applications can reduce this risk, but increase the possibility of ionisation bias due to matrix adhesion to tissue sections. We report here the use of matrix-free MSI using laser desorption ionisation performed on a 12 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. We used unprocessed tissue with no post-processing following thaw-mounting on matrix-assisted laser desorption ionisation (MALDI) indium-tin oxide (ITO) target plates. The identification and distribution of a range of phospholipids in mouse brain and kidney sections are presented and compared with previously published MALDI time-of-flight (TOF) MSI distributions.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21416534 PMCID: PMC3505379 DOI: 10.1002/rcm.4939
Source DB: PubMed Journal: Rapid Commun Mass Spectrom ISSN: 0951-4198 Impact factor: 2.419
Figure 1Matrix-free LDI FTICR MSI data: (a) matrix-free LDI spectrum of mouse brain section collected from 200 laser shots, with a laser spot diameter of 30 μm; (b) matrix-free LDI spectrum of mouse kidney section collected from 200 laser shots, with a laser spot diameter of 50 μm; and (c) CID MS/MS spectrum from mouse brain section for the potassium salt adduct of phosphatidylcholine PC (36:2). Annotated are the m/z 826.6 precursor ion, as well as the product ion at m/z 767.5, resulting from the neutral loss of trimethylamine from the choline head group [M+K−59]+. The peak at m/z 508.2 corresponds to the loss of one of the side chains (theoretical C26H46O5PK, m/z 508.2714). (d) Spatial distribution of PC (32:0), m/z 772.5, across mouse kidney section at 100 μm raster. Scale bar 1 mm; insert is an optical image taken with a CCD camera on the macro lens.
Figure 2Comparison of matrix-free LDI FTICR mass spectrometry images for phospholipid distributions across mouse brain section, with previously reported distributions obtained using MALDI TOF MSI. Scale bar 1 mm: (a) matrix-free LDI FTICR MSI data, 100 μm raster, mass window filter set to 0.001 m/z units; (b) MALDI TOF MSI data using solvent-free dry DHB matrix method, 100 μm raster, MALDI TOF. Reproduced from Puolitaival et al.